Determination of total hemispherical emissivity utilizing an in-situ calibrated, coupled experimental–simulative electron beam calorimetric approach

IF 6.1 2区 工程技术 Q1 ENGINEERING, MULTIDISCIPLINARY
Measurement Pub Date : 2026-05-05 Epub Date: 2026-03-06 DOI:10.1016/j.measurement.2026.120958
Konrad Kerber , Alexander Kreisch , Philipp Hengst , Niclas Reuter , Markus Radajewski , Lars Halbauer , Anja Buchwalder , Horst Biermann
{"title":"Determination of total hemispherical emissivity utilizing an in-situ calibrated, coupled experimental–simulative electron beam calorimetric approach","authors":"Konrad Kerber ,&nbsp;Alexander Kreisch ,&nbsp;Philipp Hengst ,&nbsp;Niclas Reuter ,&nbsp;Markus Radajewski ,&nbsp;Lars Halbauer ,&nbsp;Anja Buchwalder ,&nbsp;Horst Biermann","doi":"10.1016/j.measurement.2026.120958","DOIUrl":null,"url":null,"abstract":"<div><div>The accurate determination of the total hemispherical emission coefficient (THEC) of materials is essential for modelling radiative heat transfer in high-temperature vacuum environments. This study presents a rapid steady-state calorimetric method to determine the THEC using a vacuum electron beam (EB) facility. A graphite-coated Inconel 718 foil with a thickness comparable to the electron penetration depth was used as the emission target, allowing temperature equalization within seconds. Surface temperatures were recorded via a calibrated two-colour thermal imaging system. An in-situ calibration was conducted, using the melting point of pure copper as a fixed reference. Numerical simulations were employed to validate both the emissivity determination and the temperature calibration methodology. EB heating efficiency was determined at <span><math><mrow><mn>150</mn><mspace></mspace><mstyle><mi>k</mi><mi>e</mi><mi>V</mi></mstyle></mrow></math></span> in a combined experimental–simulative approach using Monte Carlo simulations and backscattered electron intensity capture. Temperature calibration showed high reproducibility with a median absolute deviation of <span><math><mrow><mo>±</mo><mn>0</mn><mo>.</mo><mn>4</mn><mspace></mspace><mstyle><mi>%</mi></mstyle></mrow></math></span> and a half range of <span><math><mrow><mo>±</mo><mn>1</mn><mo>.</mo><mn>1</mn><mspace></mspace><mstyle><mi>%</mi></mstyle></mrow></math></span> at <span><math><mrow><mn>1085</mn><mspace></mspace><mstyle><mo>∘</mo><mi>C</mi></mstyle></mrow></math></span>, and was shown to be transferable to other materials. EB heating efficiency slightly decreased from <span><math><mrow><mn>0</mn><mo>.</mo><mn>832</mn><mo>±</mo><mn>0</mn><mo>.</mo><mn>003</mn></mrow></math></span> at room temperature to <span><math><mrow><mn>0</mn><mo>.</mo><mn>825</mn><mo>±</mo><mn>0</mn><mo>.</mo><mn>002</mn></mrow></math></span> between <span><math><mrow><mn>800</mn><mspace></mspace><mstyle><mo>∘</mo><mi>C</mi></mstyle></mrow></math></span> to <span><math><mrow><mn>1140</mn><mspace></mspace><mstyle><mo>∘</mo><mi>C</mi></mstyle></mrow></math></span>. THEC values between <span><math><mrow><mn>0</mn><mo>.</mo><mn>88</mn></mrow></math></span> and <span><math><mrow><mn>0</mn><mo>.</mo><mn>92</mn></mrow></math></span> with a maximum half range of <span><math><mrow><mo>±</mo><mn>0</mn><mo>.</mo><mn>06</mn></mrow></math></span> were obtained in the range of <span><math><mrow><mn>840</mn><mspace></mspace><mstyle><mo>∘</mo><mi>C</mi></mstyle></mrow></math></span> to <span><math><mrow><mn>1110</mn><mspace></mspace><mstyle><mo>∘</mo><mi>C</mi></mstyle></mrow></math></span> for graphite-coated Inconel 718 with a median roughness of <span><math><mrow><msub><mrow><mi>R</mi></mrow><mrow><mi>a</mi></mrow></msub><mo>=</mo><mn>1</mn><mo>.</mo><mn>2</mn><mspace></mspace><mstyle><mi>µ</mi><mi>m</mi></mstyle></mrow></math></span>. Reflected radiation from the emission target and thermal losses from conduction and sublimation were assessed and found negligible. Results were consistent with literature, particularly under high surface roughness or pre-oxidized conditions.</div></div>","PeriodicalId":18349,"journal":{"name":"Measurement","volume":"272 ","pages":"Article 120958"},"PeriodicalIF":6.1000,"publicationDate":"2026-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0263224126006676","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The accurate determination of the total hemispherical emission coefficient (THEC) of materials is essential for modelling radiative heat transfer in high-temperature vacuum environments. This study presents a rapid steady-state calorimetric method to determine the THEC using a vacuum electron beam (EB) facility. A graphite-coated Inconel 718 foil with a thickness comparable to the electron penetration depth was used as the emission target, allowing temperature equalization within seconds. Surface temperatures were recorded via a calibrated two-colour thermal imaging system. An in-situ calibration was conducted, using the melting point of pure copper as a fixed reference. Numerical simulations were employed to validate both the emissivity determination and the temperature calibration methodology. EB heating efficiency was determined at 150keV in a combined experimental–simulative approach using Monte Carlo simulations and backscattered electron intensity capture. Temperature calibration showed high reproducibility with a median absolute deviation of ±0.4% and a half range of ±1.1% at 1085∘C, and was shown to be transferable to other materials. EB heating efficiency slightly decreased from 0.832±0.003 at room temperature to 0.825±0.002 between 800∘C to 1140∘C. THEC values between 0.88 and 0.92 with a maximum half range of ±0.06 were obtained in the range of 840∘C to 1110∘C for graphite-coated Inconel 718 with a median roughness of Ra=1.2µm. Reflected radiation from the emission target and thermal losses from conduction and sublimation were assessed and found negligible. Results were consistent with literature, particularly under high surface roughness or pre-oxidized conditions.
利用原位校准,耦合实验模拟电子束量热法测定总半球发射率
准确确定材料的总半球面辐射系数(THEC)对于模拟高温真空环境下的辐射传热至关重要。本研究提出了一种利用真空电子束(EB)装置快速测定热当量的稳态量热法。使用厚度与电子穿透深度相当的石墨涂层Inconel 718箔作为发射目标,可在几秒钟内实现温度均衡。通过校准的双色热成像系统记录表面温度。以纯铜的熔点作为固定基准,进行了现场校准。数值模拟验证了发射率测定和温度标定方法的正确性。采用蒙特卡罗模拟和背散射电子强度捕获相结合的实验模拟方法确定了150keV下的EB加热效率。温度校准结果显示,在1085°C时,校准结果的绝对中位数偏差为±0.4%,误差范围为±1.1%,具有很高的再现性,并可用于其他材料。在800°C到1140°C之间,EB的加热效率从室温下的0.832±0.003略微下降到0.825±0.002。在840°C到1110°C的范围内,镀有石墨的Inconel 718的平均粗糙度为Ra=1.2µm,其传热系数在0.88到0.92之间,最大一半范围为±0.06。对发射目标的反射辐射和传导和升华的热损失进行了评估,发现可以忽略不计。结果与文献一致,特别是在高表面粗糙度或预氧化条件下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Measurement
Measurement 工程技术-工程:综合
CiteScore
10.20
自引率
12.50%
发文量
1589
审稿时长
12.1 months
期刊介绍: Contributions are invited on novel achievements in all fields of measurement and instrumentation science and technology. Authors are encouraged to submit novel material, whose ultimate goal is an advancement in the state of the art of: measurement and metrology fundamentals, sensors, measurement instruments, measurement and estimation techniques, measurement data processing and fusion algorithms, evaluation procedures and methodologies for plants and industrial processes, performance analysis of systems, processes and algorithms, mathematical models for measurement-oriented purposes, distributed measurement systems in a connected world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书