FID-Net: an interpretable fourier and image domain convolutional dictionary network for industrial CT metal artifact reduction

IF 6.1 2区 工程技术 Q1 ENGINEERING, MULTIDISCIPLINARY
Measurement Pub Date : 2026-05-05 Epub Date: 2026-03-09 DOI:10.1016/j.measurement.2026.121083
Xin Tian , Zheng Yin , Dalong Tan , Yixin He , Changzhe Li , Tian Chen , Yijie Peng , Min Yang
{"title":"FID-Net: an interpretable fourier and image domain convolutional dictionary network for industrial CT metal artifact reduction","authors":"Xin Tian ,&nbsp;Zheng Yin ,&nbsp;Dalong Tan ,&nbsp;Yixin He ,&nbsp;Changzhe Li ,&nbsp;Tian Chen ,&nbsp;Yijie Peng ,&nbsp;Min Yang","doi":"10.1016/j.measurement.2026.121083","DOIUrl":null,"url":null,"abstract":"<div><div>In battery X-ray computed tomography (CT) imaging, artifacts emanating from internal metallic implants markedly distort electrode morphology, thereby impeding precise interpretation and quantification of internal structural features. Although sinogram‑domain correction techniques can mitigate these artifacts to some extent, they frequently introduce secondary artifacts due to localized correction errors and entail substantial computational overhead. Meanwhile, most deep learning metal artifact reduction (MAR) methods treat the task as a generic image‑restoration problem, overlooking the inherent physics of CT imaging and relying solely on off‑the‑shelf network components, which limits their interpretability. To overcome these challenges, we propose FID‑Net, an interpretable Fourier and image domain convolutional dictionary network for industrial CT metal artifact reduction. FID‑Net constructs spatial and spectral dictionaries in parallel and uses the fast Fourier transform as an efficient bridge to jointly capture global context and local details, iteratively refining dictionary coefficients to accurately model and remove metal artifacts while fully preserving electrode morphology. To validate the effectiveness of the method, we constructed a real battery CT dataset and conducted comparative experiments on extensive synthetic and real data, and the results show that the proposed FID‑Net demonstrates superior performance in MAR effectiveness and structural fidelity.</div></div>","PeriodicalId":18349,"journal":{"name":"Measurement","volume":"272 ","pages":"Article 121083"},"PeriodicalIF":6.1000,"publicationDate":"2026-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S026322412600792X","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

In battery X-ray computed tomography (CT) imaging, artifacts emanating from internal metallic implants markedly distort electrode morphology, thereby impeding precise interpretation and quantification of internal structural features. Although sinogram‑domain correction techniques can mitigate these artifacts to some extent, they frequently introduce secondary artifacts due to localized correction errors and entail substantial computational overhead. Meanwhile, most deep learning metal artifact reduction (MAR) methods treat the task as a generic image‑restoration problem, overlooking the inherent physics of CT imaging and relying solely on off‑the‑shelf network components, which limits their interpretability. To overcome these challenges, we propose FID‑Net, an interpretable Fourier and image domain convolutional dictionary network for industrial CT metal artifact reduction. FID‑Net constructs spatial and spectral dictionaries in parallel and uses the fast Fourier transform as an efficient bridge to jointly capture global context and local details, iteratively refining dictionary coefficients to accurately model and remove metal artifacts while fully preserving electrode morphology. To validate the effectiveness of the method, we constructed a real battery CT dataset and conducted comparative experiments on extensive synthetic and real data, and the results show that the proposed FID‑Net demonstrates superior performance in MAR effectiveness and structural fidelity.
一个可解释的傅立叶和图像域卷积字典网络,用于工业CT金属伪影还原
在电池x射线计算机断层扫描(CT)成像中,内部金属植入物产生的伪影明显扭曲了电极形态,从而阻碍了内部结构特征的精确解释和量化。虽然正弦图域校正技术可以在一定程度上减轻这些伪影,但由于局部校正误差,它们经常引入二次伪影,并且需要大量的计算开销。与此同时,大多数深度学习金属伪影还原(MAR)方法将该任务视为一般的图像恢复问题,忽略了CT成像的固有物理特性,仅依赖于现成的网络组件,这限制了它们的可解释性。为了克服这些挑战,我们提出了FID - Net,这是一种可解释的傅立叶和图像域卷积字典网络,用于工业CT金属伪影还原。FID - Net并行构建空间和光谱字典,并使用快速傅立叶变换作为有效的桥梁,共同捕获全局背景和局部细节,迭代地改进字典系数,以准确地建模和去除金属伪影,同时完全保留电极形态。为了验证该方法的有效性,我们构建了一个真实电池CT数据集,并对大量合成数据和真实数据进行了对比实验,结果表明所提出的FID - Net在MAR有效性和结构保真度方面表现出优异的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Measurement
Measurement 工程技术-工程:综合
CiteScore
10.20
自引率
12.50%
发文量
1589
审稿时长
12.1 months
期刊介绍: Contributions are invited on novel achievements in all fields of measurement and instrumentation science and technology. Authors are encouraged to submit novel material, whose ultimate goal is an advancement in the state of the art of: measurement and metrology fundamentals, sensors, measurement instruments, measurement and estimation techniques, measurement data processing and fusion algorithms, evaluation procedures and methodologies for plants and industrial processes, performance analysis of systems, processes and algorithms, mathematical models for measurement-oriented purposes, distributed measurement systems in a connected world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书