Application of the ultrasonic oscillation flotation method in paraffin section preparation.

IF 2.2 4区 生物学 Q3 CELL BIOLOGY
Histology and histopathology Pub Date : 2026-08-01 Epub Date: 2026-03-03 DOI:10.14670/HH-25-053
Min Zhang, Yue Chen, Lü Ren, Jinzhi Xia, Lu Tao, Jianguo Hu, Jing Li, Xiaofeng Zhang, Zhijun Geng, Yueyue Wang, Xue Song
{"title":"Application of the ultrasonic oscillation flotation method in paraffin section preparation.","authors":"Min Zhang, Yue Chen, Lü Ren, Jinzhi Xia, Lu Tao, Jianguo Hu, Jing Li, Xiaofeng Zhang, Zhijun Geng, Yueyue Wang, Xue Song","doi":"10.14670/HH-25-053","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To enhance the quality and efficiency of paraffin-embedded pathological section preparation, this study aims to investigate the potential benefits of utilizing the ultrasound oscillation flotation method (UOFM) for section spreading.</p><p><strong>Methods: </strong>Specimens of various tissue types were processed using both the conventional and UOFM for section spreading. The presence of wrinkles or damage during this process was assessed through HE staining, with the number of wrinkles being quantified. The optimal frequency and power density for section spreading were determined by evaluating the qualified rate of sections at various frequencies and power densities, and the average time required for section spreading was compared between the two methods.</p><p><strong>Results: </strong>The results showed that pathological sections of various tissue types rarely showed paraffin dissolution and section breaking after the UOFM. HE staining also revealed that the group exhibited significantly reduced wrinkling and a more intact tissue structure compared with the conventional method group (<i>p</i><0.05). Statistical analysis further indicated that the highest rate of section qualification was achieved when employing a frequency of 33 kHz with a power density of 60% or a frequency of 40 kHz with a power density of 75% (<i>p</i><0.05). Additionally, the mean duration of section spreading in the group utilizing the UOFM was significantly reduced (<i>p</i><0.05).</p><p><strong>Conclusions: </strong>The UOFM effectively maintains the structural integrity of paraffin pathological sections, significantly enhancing the quality of sections and optimizing section preparation efficiency.</p>","PeriodicalId":13164,"journal":{"name":"Histology and histopathology","volume":" ","pages":"1451-1457"},"PeriodicalIF":2.2000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Histology and histopathology","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.14670/HH-25-053","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CELL BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To enhance the quality and efficiency of paraffin-embedded pathological section preparation, this study aims to investigate the potential benefits of utilizing the ultrasound oscillation flotation method (UOFM) for section spreading.

Methods: Specimens of various tissue types were processed using both the conventional and UOFM for section spreading. The presence of wrinkles or damage during this process was assessed through HE staining, with the number of wrinkles being quantified. The optimal frequency and power density for section spreading were determined by evaluating the qualified rate of sections at various frequencies and power densities, and the average time required for section spreading was compared between the two methods.

Results: The results showed that pathological sections of various tissue types rarely showed paraffin dissolution and section breaking after the UOFM. HE staining also revealed that the group exhibited significantly reduced wrinkling and a more intact tissue structure compared with the conventional method group (p<0.05). Statistical analysis further indicated that the highest rate of section qualification was achieved when employing a frequency of 33 kHz with a power density of 60% or a frequency of 40 kHz with a power density of 75% (p<0.05). Additionally, the mean duration of section spreading in the group utilizing the UOFM was significantly reduced (p<0.05).

Conclusions: The UOFM effectively maintains the structural integrity of paraffin pathological sections, significantly enhancing the quality of sections and optimizing section preparation efficiency.

超声振荡浮选法在石蜡切片制备中的应用。
目的:为了提高石蜡包埋病理切片制备的质量和效率,本研究旨在探讨超声振荡浮选法(UOFM)对切片扩散的潜在益处。方法:对不同组织类型的标本分别采用常规和UOFM进行切片扩散处理。在此过程中,通过HE染色评估皱纹或损伤的存在,并量化皱纹的数量。通过评价不同频率和功率密度下的切片合格率,确定最佳的切片铺开频率和功率密度,并比较两种方法铺开切片所需的平均时间。结果:UOFM术后各组织类型病理切片均未见石蜡溶解和切片破裂。HE染色还显示,与常规方法组相比,UOFM组皱纹明显减少,组织结构更完整(ppp)。结论:UOFM有效地保持了石蜡病理切片的结构完整性,显著提高了切片质量,优化了切片制备效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Histology and histopathology
Histology and histopathology 生物-病理学
CiteScore
3.90
自引率
0.00%
发文量
232
审稿时长
2 months
期刊介绍: HISTOLOGY AND HISTOPATHOLOGY is a peer-reviewed international journal, the purpose of which is to publish original and review articles in all fields of the microscopical morphology, cell biology and tissue engineering; high quality is the overall consideration. Its format is the standard international size of 21 x 27.7 cm. One volume is published every year (more than 1,300 pages, approximately 90 original works and 40 reviews). Each volume consists of 12 numbers published monthly online. The printed version of the journal includes 4 books every year; each of them compiles 3 numbers previously published online.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书