Biomechanical evaluation of reconstruction plates in bone-grafted mandibular defects: a finite element analysis

IF 2.4 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Diogo de Vasconcelos Macedo , Milena Gomes Melo Leite , Maria Eduarda Carlos Conceição , Nicolau Conte Neto , Marcelo Silva Monnazzi
{"title":"Biomechanical evaluation of reconstruction plates in bone-grafted mandibular defects: a finite element analysis","authors":"Diogo de Vasconcelos Macedo ,&nbsp;Milena Gomes Melo Leite ,&nbsp;Maria Eduarda Carlos Conceição ,&nbsp;Nicolau Conte Neto ,&nbsp;Marcelo Silva Monnazzi","doi":"10.1016/j.jormas.2026.102716","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To evaluate, through three-dimensional finite element analysis (FEA), the stress and strain distribution in reconstruction plates of different thicknesses used for fixation of bone-grafted segmental mandibular defects.</div></div><div><h3>Method</h3><div>A dentate mandibular model was obtained from computed tomography data and digitally processed for FEA using ANSYS 7.0. Three reconstruction plate models (2.0, 2.4, and 3.0 mm thick) were applied to simulate defects in the symphyseal, body, and angle regions of the mandible, each associated with block bone grafts and fixed using 2.4-mm locking screws. A 300-N vertical occlusal load and muscle vectors representing masticatory forces were simulated. Stress distribution was analyzed according to von Mises criteria across plates, screws, and bone graft blocks.</div></div><div><h3>Results</h3><div>Increasing plate thickness reduced stress concentration within the plates but significantly increased stress on the fixation screws, particularly those adjacent to osteotomy lines. The symphyseal defect exhibited the highest stress values, followed by the body and angle defects. Stress values within bone graft blocks remained low (&lt;250 MPa), indicating minimal deformation.</div></div><div><h3>Conclusion</h3><div>Thicker reconstruction plates enhance mechanical resistance but increase stress concentration on fixation screws, especially near osteotomies, suggesting a higher risk of screw loosening or peri‑implant bone resorption. The anterior mandible demonstrated the most unfavorable stress distribution. Locking fixation systems are recommended when rigid plates are used to mitigate screw-related complications.</div></div>","PeriodicalId":55993,"journal":{"name":"Journal of Stomatology Oral and Maxillofacial Surgery","volume":"127 3","pages":"Article 102716"},"PeriodicalIF":2.4000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Stomatology Oral and Maxillofacial Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S246878552600008X","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/13 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

To evaluate, through three-dimensional finite element analysis (FEA), the stress and strain distribution in reconstruction plates of different thicknesses used for fixation of bone-grafted segmental mandibular defects.

Method

A dentate mandibular model was obtained from computed tomography data and digitally processed for FEA using ANSYS 7.0. Three reconstruction plate models (2.0, 2.4, and 3.0 mm thick) were applied to simulate defects in the symphyseal, body, and angle regions of the mandible, each associated with block bone grafts and fixed using 2.4-mm locking screws. A 300-N vertical occlusal load and muscle vectors representing masticatory forces were simulated. Stress distribution was analyzed according to von Mises criteria across plates, screws, and bone graft blocks.

Results

Increasing plate thickness reduced stress concentration within the plates but significantly increased stress on the fixation screws, particularly those adjacent to osteotomy lines. The symphyseal defect exhibited the highest stress values, followed by the body and angle defects. Stress values within bone graft blocks remained low (<250 MPa), indicating minimal deformation.

Conclusion

Thicker reconstruction plates enhance mechanical resistance but increase stress concentration on fixation screws, especially near osteotomies, suggesting a higher risk of screw loosening or peri‑implant bone resorption. The anterior mandible demonstrated the most unfavorable stress distribution. Locking fixation systems are recommended when rigid plates are used to mitigate screw-related complications.
骨移植下颌骨缺损重建钢板的生物力学评价:有限元分析。
目的:通过三维有限元分析(FEA),评价不同厚度重建板固定骨移植下颌骨节段性缺损的应力应变分布。方法:利用计算机断层扫描数据建立齿状下颌骨模型,利用ANSYS 7.0软件进行有限元分析。三个重建板模型(2.0、2.4和3.0 mm厚)用于模拟下颌骨联合、体和角区缺陷,每个模型都与块骨移植物相关,并使用2.4 mm锁定螺钉进行固定。模拟300-N垂直咬合负荷和代表咀嚼力的肌肉矢量。根据von Mises标准分析钢板、螺钉和骨移植块之间的应力分布。结果:增加钢板厚度减少了钢板内的应力集中,但明显增加了固定螺钉上的应力,特别是截骨线附近的应力。联合缺损的应力值最高,其次为体缺损和角缺损。结论:较厚的重建钢板增加了机械阻力,但增加了固定螺钉的应力集中,特别是在截骨附近,提示螺钉松动或种植体周围骨吸收的风险较高。前下颌表现出最不利的应力分布。当使用刚性钢板以减轻螺钉相关并发症时,建议使用锁定固定系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Stomatology Oral and Maxillofacial Surgery
Journal of Stomatology Oral and Maxillofacial Surgery Surgery, Dentistry, Oral Surgery and Medicine, Otorhinolaryngology and Facial Plastic Surgery
CiteScore
2.30
自引率
9.10%
发文量
0
审稿时长
23 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书