{"title":"Analysis of intraoperative radiation exposure in paediatric orthopaedic and trauma patients: a comparative cohort study.","authors":"Philipp Kriechling, Fabian Luca Meichtry, Maria Anna Smolle, Helga Preiss, Michael Zellner, Yvonne Kaeser, Nadja A Farshad-Amacker, Thomas Dreher","doi":"10.1136/bmjpo-2025-003666","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To reliably analyse the intraoperative radiation exposure in paediatric orthopaedic trauma surgery (POTS).</p><p><strong>Design: </strong>Retrospective, comparative cohort study.</p><p><strong>Setting: </strong>Single-centre, academic tertiary referral hospital.</p><p><strong>Participants: </strong>2271 surgical cases of 1965 paediatric patients (median age 9 years (IQR, 6 to 12), 41% female) who underwent orthopaedic trauma surgery between 2016 and 2021.</p><p><strong>Main outcome measures: </strong>Radiation exposure was measured as dose area product (DAP, cGycm<sup>2</sup>) from intraoperative dose reports and categorised by anatomical region. Subsequently, factors in relation to one preoperative image of the region (rDAP) and in relation to a weight-corrected chest x-ray (rDAP chest) were calculated. Further, effective dose (µSv) was estimated.</p><p><strong>Results: </strong>A total of 195 667 x-rays were included in the analysis comprising 1584 (70%) trauma cases and 687 (30%) elective orthopaedic cases. The median DAP measured 30 cGycm<sup>2</sup> (IQR, 14 to 59) with a median of 62 (IQR, 34 to 107) exposure events per case. The applied DAP was comparable between trauma cases and elective cases (p=0.4). The rDAP reached 26 (IQR, 8 to 69), with the largest factors for multilevel surgery at the upper extremity, elbow and forearm with factors of 89, 56 and 55, respectively. The rDAP chest was highest for hip, multilevel upper extremity and shoulder with values of 27, 26 and 22. Analysis of effective dose revealed a median exposure of 13 µSv (IQR, 3 to 31) with highest values for spine, hip and shoulder reaching 98 µSv (IQR, 49 to 159), 73 µSv (IQR, 30 to 186) and 56 µSv (23 to 126), respectively.</p><p><strong>Conclusion: </strong>The data suggest that intraoperative radiation imaging during POTS exposes paediatric patients to a substantial amount of radiation in comparison to preoperative x-rays. In detail, analysis revealed higher effective doses for all procedures close to the trunk. Particularly concerning were the outliers reaching exponentially higher values. This study highlights the necessity for additional research on intraoperative radiation doses, emphasising the importance of minimising radiation exposure in this vulnerable patient cohort.</p><p><strong>Trial registration: </strong>Cantonal ethics committee of Zurich (BASEC 2022-01486).</p>","PeriodicalId":9069,"journal":{"name":"BMJ Paediatrics Open","volume":"9 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12542719/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Paediatrics Open","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/bmjpo-2025-003666","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To reliably analyse the intraoperative radiation exposure in paediatric orthopaedic trauma surgery (POTS).

Design: Retrospective, comparative cohort study.

Setting: Single-centre, academic tertiary referral hospital.

Participants: 2271 surgical cases of 1965 paediatric patients (median age 9 years (IQR, 6 to 12), 41% female) who underwent orthopaedic trauma surgery between 2016 and 2021.

Main outcome measures: Radiation exposure was measured as dose area product (DAP, cGycm2) from intraoperative dose reports and categorised by anatomical region. Subsequently, factors in relation to one preoperative image of the region (rDAP) and in relation to a weight-corrected chest x-ray (rDAP chest) were calculated. Further, effective dose (µSv) was estimated.

Results: A total of 195 667 x-rays were included in the analysis comprising 1584 (70%) trauma cases and 687 (30%) elective orthopaedic cases. The median DAP measured 30 cGycm2 (IQR, 14 to 59) with a median of 62 (IQR, 34 to 107) exposure events per case. The applied DAP was comparable between trauma cases and elective cases (p=0.4). The rDAP reached 26 (IQR, 8 to 69), with the largest factors for multilevel surgery at the upper extremity, elbow and forearm with factors of 89, 56 and 55, respectively. The rDAP chest was highest for hip, multilevel upper extremity and shoulder with values of 27, 26 and 22. Analysis of effective dose revealed a median exposure of 13 µSv (IQR, 3 to 31) with highest values for spine, hip and shoulder reaching 98 µSv (IQR, 49 to 159), 73 µSv (IQR, 30 to 186) and 56 µSv (23 to 126), respectively.

Conclusion: The data suggest that intraoperative radiation imaging during POTS exposes paediatric patients to a substantial amount of radiation in comparison to preoperative x-rays. In detail, analysis revealed higher effective doses for all procedures close to the trunk. Particularly concerning were the outliers reaching exponentially higher values. This study highlights the necessity for additional research on intraoperative radiation doses, emphasising the importance of minimising radiation exposure in this vulnerable patient cohort.

Trial registration: Cantonal ethics committee of Zurich (BASEC 2022-01486).

儿科骨科和创伤患者术中辐射暴露分析:一项比较队列研究。
目的:对小儿骨科创伤手术(POTS)术中辐射暴露进行可靠分析。设计:回顾性、比较队列研究。环境:单中心、学术三级转诊医院。参与者:在2016年至2021年期间接受骨科创伤手术的1965例儿童患者(中位年龄9岁(IQR, 6至12岁),其中41%为女性)的2271例手术病例。主要结果测量:根据术中剂量报告,以剂量面积积(DAP, cGycm2)测量辐射暴露,并按解剖区域分类。随后,计算与术前区域图像(rDAP)和体重校正胸片(rDAP胸部)相关的因素。进一步估计了有效剂量(µSv)。结果:共纳入195 667张x线片,其中创伤病例1584例(70%),择期骨科病例687例(30%)。中位DAP测量为30 cGycm2 (IQR, 14至59),中位暴露事件为62 (IQR, 34至107)。创伤病例与选择性病例应用DAP具有可比性(p=0.4)。rDAP为26 (IQR为8 ~ 69),其中上肢、肘部和前臂多节段手术的影响因子最大,分别为89、56和55。胸部的rDAP在髋部、多节段上肢和肩部最高,分别为27、26和22。有效剂量分析显示,中位暴露为13µSv (IQR, 3 ~ 31),脊柱、髋关节和肩部的最高值分别达到98µSv (IQR, 49 ~ 159)、73µSv (IQR, 30 ~ 186)和56µSv (IQR, 23 ~ 126)。结论:数据表明,与术前x线相比,POTS术中放射成像使儿科患者暴露于大量的辐射。详细分析显示,靠近躯干的所有程序的有效剂量都较高。特别令人担忧的是异常值达到指数级高的值。这项研究强调了对术中辐射剂量进行进一步研究的必要性,强调了在这一脆弱患者群体中尽量减少辐射暴露的重要性。试验注册:苏黎世州伦理委员会(BASEC 2022-01486)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMJ Paediatrics Open
BMJ Paediatrics Open Medicine-Pediatrics, Perinatology and Child Health
CiteScore
4.10
自引率
3.80%
发文量
124
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信