Yimin Luo , Shijia Chen , Cheng Wang , Yuting Ni , He Zhang , Shengnan Lyu , Tianxue Zhang
{"title":"Design and evaluation of FBG-based vascular shape reconstruction sensors through animal experiments","authors":"Yimin Luo , Shijia Chen , Cheng Wang , Yuting Ni , He Zhang , Shengnan Lyu , Tianxue Zhang","doi":"10.1016/j.measurement.2025.117769","DOIUrl":null,"url":null,"abstract":"<div><div>Vascular interventional procedure primarily relies on iodine contrast agent angiography, exposing both patients and medical personnel to radiation. The urgent demand for radiation-free, flexible, and real-time diagnostic methods for vascular interventional surgery triggers this study. A multi-grating three-core fiber Bragg grating (FBG) sensor with an integrated flexible conduit device has been investigated. A porcine artery shape reconstruction experiment is conducted using the device, and an in-vivo experimental protocol is proposed. Vascular shape is reconstructed using an improved HEM (i-HEM) algorithm and compared with computed tomography (CT) images. The average reconstruction errors of 1.5116 mm and 2.1674 mm with percentage errors of 0.8892% and 1.2749% respectively suggest high accuracy of the i-HEM algorithm in vascular shape reconstruction. Additionally, the MRI compatibility of the flexible catheter device is validated with a signal-to-noise (SNR) ratio of 2.90%. This study provides a feasible solution for diagnosing vascular intervention using FBGs.</div></div>","PeriodicalId":18349,"journal":{"name":"Measurement","volume":"254 ","pages":"Article 117769"},"PeriodicalIF":5.2000,"publicationDate":"2025-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0263224125011285","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Vascular interventional procedure primarily relies on iodine contrast agent angiography, exposing both patients and medical personnel to radiation. The urgent demand for radiation-free, flexible, and real-time diagnostic methods for vascular interventional surgery triggers this study. A multi-grating three-core fiber Bragg grating (FBG) sensor with an integrated flexible conduit device has been investigated. A porcine artery shape reconstruction experiment is conducted using the device, and an in-vivo experimental protocol is proposed. Vascular shape is reconstructed using an improved HEM (i-HEM) algorithm and compared with computed tomography (CT) images. The average reconstruction errors of 1.5116 mm and 2.1674 mm with percentage errors of 0.8892% and 1.2749% respectively suggest high accuracy of the i-HEM algorithm in vascular shape reconstruction. Additionally, the MRI compatibility of the flexible catheter device is validated with a signal-to-noise (SNR) ratio of 2.90%. This study provides a feasible solution for diagnosing vascular intervention using FBGs.
期刊介绍:
Contributions are invited on novel achievements in all fields of measurement and instrumentation science and technology. Authors are encouraged to submit novel material, whose ultimate goal is an advancement in the state of the art of: measurement and metrology fundamentals, sensors, measurement instruments, measurement and estimation techniques, measurement data processing and fusion algorithms, evaluation procedures and methodologies for plants and industrial processes, performance analysis of systems, processes and algorithms, mathematical models for measurement-oriented purposes, distributed measurement systems in a connected world.