Evaluation of visual function and morphological changes in patients with adrenoleukodystrophy using SS-OCT and PVEP.

IF 2.6 4区 医学 Q2 OPHTHALMOLOGY
Yongqiu Yu, Lujie Zhang, Shuiqian Wen, Chongyi Li, Liang Tan, Xian Wu, Yangcheng Zou, Ting Liu
{"title":"Evaluation of visual function and morphological changes in patients with adrenoleukodystrophy using SS-OCT and PVEP.","authors":"Yongqiu Yu, Lujie Zhang, Shuiqian Wen, Chongyi Li, Liang Tan, Xian Wu, Yangcheng Zou, Ting Liu","doi":"10.1007/s10633-025-10021-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aims to evaluate visual function and morphological changes in patients with adrenoleukodystrophy (ALD) through sweep-source optical coherence tomography (SS-OCT) and patterned visual evoked potentials (PVEP), with the goal of providing more accurate and comprehensive data for the diagnosis, monitoring, and assessment of treatment efficacy in patients with ALD.</p><p><strong>Methods: </strong>This study included 46 ALD patients and 44 healthy controls. The thickness of the retinal nerve fiber layer (RNFL) around the optic disc, as well as the macular RNFL and ganglion cell-inner plexiform layer (GCIPL) thickness, was assessed using SS-OCT. The peak time and amplitude of the P100 wave were also measured using PVEP. Factors that were statistically significant in the univariate analysis were subjected to stepwise binary logistic regression analysis for further investigation. Predictive performance was evaluated by constructing receiver operating characteristic (ROC) curves and compared using DeLong's test.</p><p><strong>Results: </strong>Compared with the control patients, ALD patients presented a significant increase in the peak time of the P100 wave (P < 0.05); however, no notable difference in amplitude was observed (P > 0.05). Additionally, substantial decreases in the RNFL and GCIPL thicknesses were observed within the parafoveal ring, especially in the superior and nasal quadrants (P < 0.05). The area under the curve for the binary logistic stepwise regression model was 0.883, with a sensitivity of 0.95, which surpassed the performance of the individual parameters.</p><p><strong>Conclusion: </strong>ALD patients present with abnormal retinal structures and a PVEP peak time delay. Combining these two parameters could increase the accuracy of an early ALD diagnosis.</p>","PeriodicalId":11207,"journal":{"name":"Documenta Ophthalmologica","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Documenta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10633-025-10021-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aims to evaluate visual function and morphological changes in patients with adrenoleukodystrophy (ALD) through sweep-source optical coherence tomography (SS-OCT) and patterned visual evoked potentials (PVEP), with the goal of providing more accurate and comprehensive data for the diagnosis, monitoring, and assessment of treatment efficacy in patients with ALD.

Methods: This study included 46 ALD patients and 44 healthy controls. The thickness of the retinal nerve fiber layer (RNFL) around the optic disc, as well as the macular RNFL and ganglion cell-inner plexiform layer (GCIPL) thickness, was assessed using SS-OCT. The peak time and amplitude of the P100 wave were also measured using PVEP. Factors that were statistically significant in the univariate analysis were subjected to stepwise binary logistic regression analysis for further investigation. Predictive performance was evaluated by constructing receiver operating characteristic (ROC) curves and compared using DeLong's test.

Results: Compared with the control patients, ALD patients presented a significant increase in the peak time of the P100 wave (P < 0.05); however, no notable difference in amplitude was observed (P > 0.05). Additionally, substantial decreases in the RNFL and GCIPL thicknesses were observed within the parafoveal ring, especially in the superior and nasal quadrants (P < 0.05). The area under the curve for the binary logistic stepwise regression model was 0.883, with a sensitivity of 0.95, which surpassed the performance of the individual parameters.

Conclusion: ALD patients present with abnormal retinal structures and a PVEP peak time delay. Combining these two parameters could increase the accuracy of an early ALD diagnosis.

应用SS-OCT和PVEP评价肾上腺脑白质营养不良患者的视觉功能和形态学改变。
目的:本研究旨在通过扫描源光学相干断层扫描(SS-OCT)和视觉诱发电位模式(PVEP)评估肾上腺脑白质营养不良(ALD)患者的视觉功能和形态学变化,为ALD患者的诊断、监测和治疗效果评估提供更准确、更全面的数据。方法:本研究纳入46例ALD患者和44例健康对照。采用SS-OCT检测视盘周围视网膜神经纤维层(RNFL)的厚度、黄斑视网膜神经纤维层(RNFL)和神经节细胞-内丛状层(GCIPL)的厚度。用PVEP测量了P100波的峰值时间和振幅。单因素分析中有统计学意义的因素进行逐步二元logistic回归分析,进一步调查。通过构建受试者工作特征(ROC)曲线评价预测效果,并采用DeLong检验进行比较。结果:与对照组相比,ALD患者P100波峰值时间明显增加(P < 0.05)。此外,在中央凹旁环内观察到RNFL和GCIPL厚度明显减少,特别是在上象限和鼻象限(P结论:ALD患者存在视网膜结构异常和PVEP峰值时间延迟。结合这两个参数可以提高早期ALD诊断的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Documenta Ophthalmologica
Documenta Ophthalmologica 医学-眼科学
CiteScore
3.50
自引率
21.40%
发文量
46
审稿时长
>12 weeks
期刊介绍: Documenta Ophthalmologica is an official publication of the International Society for Clinical Electrophysiology of Vision. The purpose of the journal is to promote the understanding and application of clinical electrophysiology of vision. Documenta Ophthalmologica will publish reviews, research articles, technical notes, brief reports and case studies which inform the readers about basic and clinical sciences related to visual electrodiagnosis and means to improve diagnosis and clinical management of patients using visual electrophysiology. Studies may involve animals or humans. In either case appropriate care must be taken to follow the Declaration of Helsinki for human subject or appropriate humane standards of animal care (e.g., the ARVO standards on Animal Care and Use).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信