Geographic Atrophy and Peripheral Atrophy: Quantitative Analysis with Ultra-Widefield Autofluorescence.

IF 1.9 4区 医学 Q2 OPHTHALMOLOGY
Ophthalmologica Pub Date : 2025-01-01 Epub Date: 2025-04-08 DOI:10.1159/000544958
Daniele De Geronimo, Mariacristina Parravano, Riccardo Sacconi, Eliana Costanzo, Monica Varano, Giuseppe Querques
{"title":"Geographic Atrophy and Peripheral Atrophy: Quantitative Analysis with Ultra-Widefield Autofluorescence.","authors":"Daniele De Geronimo, Mariacristina Parravano, Riccardo Sacconi, Eliana Costanzo, Monica Varano, Giuseppe Querques","doi":"10.1159/000544958","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>To analyze and correlate the topographic distribution of atrophic areas at the posterior pole and peripheral retina in subjects with geographic atrophy (GA) using ultra-widefield fundus autofluorescence (FAF) imaging.</p><p><strong>Methods: </strong>This multicenter observational study included 15 patients (9 males, 19 eyes) with coexisting GA and peripheral atrophy. All eyes were imaged with Ultra-widefield Optos California (Optos, PLC, Dunfermline, Scotland) to acquire ultra-widefield (200°) color and FAF images centered on the fovea, superior, inferior, nasal, and temporal sectors. The extent of GA in the central FAF image and the peripheral atrophic areas in the peripheral FAF images were measured by manually defining the boundaries of the atrophic regions using the \"ROI free\" function integrated into the device software. The values obtained were then analyzed and correlated.</p><p><strong>Results: </strong>The mean ± standard deviation (SD) GA size was 13.9 ± 15.0 mm2 (range: 1.8-71.3 mm2) and the total peripheral atrophy was 51.0 ± 68.3 mm2 (range: 1.4-292.1 mm2). The topographic analysis showed that the mean ± SD of superior peripheral atrophy was 9.0 ± 20.6 mm2, temporal atrophy was 30.5 ± 55.9 mm2, inferior atrophy was 9.3 ± 16.3 mm2, and nasal atrophy was 1.8 ± 3.9 mm2. GA size was significantly correlated with total peripheral atrophy (Rho = 0.463, p = 0.046) and temporal peripheral atrophy (Rho = 0.474, p = 0.040), whereas no correlations were found with peripheral atrophy in the remaining sectors.</p><p><strong>Conclusion: </strong>Ultra-widefield autofluorescence is a valuable technique for visualizing and assessing the extent of macular and peripheral atrophy. Macular atrophy correlates significantly with total and temporal peripheral atrophy but demonstrates no significant correlation with atrophy in the remaining sectors.</p>","PeriodicalId":19595,"journal":{"name":"Ophthalmologica","volume":" ","pages":"168-174"},"PeriodicalIF":1.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000544958","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: To analyze and correlate the topographic distribution of atrophic areas at the posterior pole and peripheral retina in subjects with geographic atrophy (GA) using ultra-widefield fundus autofluorescence (FAF) imaging.

Methods: This multicenter observational study included 15 patients (9 males, 19 eyes) with coexisting GA and peripheral atrophy. All eyes were imaged with Ultra-widefield Optos California (Optos, PLC, Dunfermline, Scotland) to acquire ultra-widefield (200°) color and FAF images centered on the fovea, superior, inferior, nasal, and temporal sectors. The extent of GA in the central FAF image and the peripheral atrophic areas in the peripheral FAF images were measured by manually defining the boundaries of the atrophic regions using the "ROI free" function integrated into the device software. The values obtained were then analyzed and correlated.

Results: The mean ± standard deviation (SD) GA size was 13.9 ± 15.0 mm2 (range: 1.8-71.3 mm2) and the total peripheral atrophy was 51.0 ± 68.3 mm2 (range: 1.4-292.1 mm2). The topographic analysis showed that the mean ± SD of superior peripheral atrophy was 9.0 ± 20.6 mm2, temporal atrophy was 30.5 ± 55.9 mm2, inferior atrophy was 9.3 ± 16.3 mm2, and nasal atrophy was 1.8 ± 3.9 mm2. GA size was significantly correlated with total peripheral atrophy (Rho = 0.463, p = 0.046) and temporal peripheral atrophy (Rho = 0.474, p = 0.040), whereas no correlations were found with peripheral atrophy in the remaining sectors.

Conclusion: Ultra-widefield autofluorescence is a valuable technique for visualizing and assessing the extent of macular and peripheral atrophy. Macular atrophy correlates significantly with total and temporal peripheral atrophy but demonstrates no significant correlation with atrophy in the remaining sectors.

地理萎缩和外周萎缩:超宽视场自体荧光定量分析。
目的:利用超广角眼底自体荧光(FAF)成像技术,分析地理萎缩(GA)患者视网膜后极及周围区萎缩区域的地形分布并进行相关性分析。方法:采用多中心观察性研究,纳入15例GA合并周围性萎缩患者(男9例,眼19例)。所有眼睛使用加州超宽视场Optos (Optos, PLC, Dunfermline, Scotland)成像,获得以中央窝、上、下、鼻和颞区为中心的超宽视场(200°)彩色FAF图像。利用集成在设备软件中的“ROI free”功能,手动定义萎缩区域的边界,测量FAF中心图像和外围FAF图像中外围萎缩区域的GA程度。然后对所得值进行分析和关联。结果:GA的平均±SD大小为13.9±15.0 mm2[范围:1.8 ~ 71.3 mm2],周围总萎缩51.0±68.3 mm2[范围:1.4 ~ 292.1 mm2]。地形分析显示,上周萎缩的平均值±SD为9.0±20.6 mm2,颞叶萎缩30.5±55.9 mm2,下周萎缩9.3±16.3 mm2,鼻萎缩1.8±3.9 mm2。GA大小与总外周萎缩呈显著相关(Rho=。463, p=.046)和颞外周萎缩(Rho=。474, p= 0.040),而其余部分的外周萎缩没有发现相关性。结论:超宽视场自体荧光是一种有价值的黄斑和周围萎缩程度的可视化和评估技术。黄斑萎缩与总和颞外周萎缩显著相关,但与其余部分的萎缩无显著相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ophthalmologica
Ophthalmologica 医学-眼科学
CiteScore
5.10
自引率
3.80%
发文量
39
审稿时长
3 months
期刊介绍: Published since 1899, ''Ophthalmologica'' has become a frequently cited guide to international work in clinical and experimental ophthalmology. It contains a selection of patient-oriented contributions covering the etiology of eye diseases, diagnostic techniques, and advances in medical and surgical treatment. Straightforward, factual reporting provides both interesting and useful reading. In addition to original papers, ''Ophthalmologica'' features regularly timely reviews in an effort to keep the reader well informed and updated. The large international circulation of this journal reflects its importance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信