Yunyun Gu, Max Lennart Feuerstein and Benedikt Warth*,
{"title":"High-Throughput Solid Phase Extraction for Targeted and Nontargeted Exposomics","authors":"Yunyun Gu, Max Lennart Feuerstein and Benedikt Warth*, ","doi":"10.1021/acs.analchem.4c0617710.1021/acs.analchem.4c06177","DOIUrl":null,"url":null,"abstract":"<p >Characterizing the chemical exposome relies on advanced instrumentation including tandem mass spectrometry coupled to liquid chromatography (LC-MS/MS), and nontargeted analysis (NTA) using high-resolution MS. However, proper sample pretreatment, balancing broad analyte coverage, method robustness, and throughput remain a major bottleneck in exposomics. Here, we developed a robust and scalable solid phase extraction (SPE) protocol for human urine and plasma and optimized it for a panel of 94 highly diverse environmental and food-related contaminants (LogP −0.7 to 6.8). Extraction recoveries (RE) and signal suppression and enhancement (SSE) were determined using targeted LC-MS/MS. Acceptable REs (60–140%) were achieved for >70% of analytes, and acceptable SSE values (60–140%) for 86% and 90% in urine and plasma, respectively. Subsequently, the method was transferred to 96-well plate format, significantly improving throughput to meet the capacity requirements needed for exposome-wide association studies (ExWAS). The established workflow is approximately 10× faster than routinely used metabolomics-based protein precipitation approaches when comparing the estimated total analysis time for 1000 samples. The method’s applicability for NTA and suspect screening was tested and compared to a generic protein precipitation protocol using NIST standard reference materials for urine (SRM 3672) and plasma (SRM 1950). Favorable performance was shown for the protein precipitation workflow while the SPE protocol demonstrated promising results. The developed workflow is thus not only superior for future high-throughput targeted exposomics but also offers an option for NTA applications. The presented well-balanced approach is scalable and also applicable to research in the fields of pharmacology, food safety, and systems toxicology.</p>","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"97 11","pages":"6075–6082 6075–6082"},"PeriodicalIF":6.7000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/acs.analchem.4c06177","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acs.analchem.4c06177","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Characterizing the chemical exposome relies on advanced instrumentation including tandem mass spectrometry coupled to liquid chromatography (LC-MS/MS), and nontargeted analysis (NTA) using high-resolution MS. However, proper sample pretreatment, balancing broad analyte coverage, method robustness, and throughput remain a major bottleneck in exposomics. Here, we developed a robust and scalable solid phase extraction (SPE) protocol for human urine and plasma and optimized it for a panel of 94 highly diverse environmental and food-related contaminants (LogP −0.7 to 6.8). Extraction recoveries (RE) and signal suppression and enhancement (SSE) were determined using targeted LC-MS/MS. Acceptable REs (60–140%) were achieved for >70% of analytes, and acceptable SSE values (60–140%) for 86% and 90% in urine and plasma, respectively. Subsequently, the method was transferred to 96-well plate format, significantly improving throughput to meet the capacity requirements needed for exposome-wide association studies (ExWAS). The established workflow is approximately 10× faster than routinely used metabolomics-based protein precipitation approaches when comparing the estimated total analysis time for 1000 samples. The method’s applicability for NTA and suspect screening was tested and compared to a generic protein precipitation protocol using NIST standard reference materials for urine (SRM 3672) and plasma (SRM 1950). Favorable performance was shown for the protein precipitation workflow while the SPE protocol demonstrated promising results. The developed workflow is thus not only superior for future high-throughput targeted exposomics but also offers an option for NTA applications. The presented well-balanced approach is scalable and also applicable to research in the fields of pharmacology, food safety, and systems toxicology.
期刊介绍:
Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.