Simultaneous Measurement of Total Ammonia Nitrogen and Free Ammonia via Integrated Electrochemical Acidification─Optode Flow Cell

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Fabian Steininger, Theresa Merl, Niels Peter Revsbech, Klaus Koren
{"title":"Simultaneous Measurement of Total Ammonia Nitrogen and Free Ammonia via Integrated Electrochemical Acidification─Optode Flow Cell","authors":"Fabian Steininger, Theresa Merl, Niels Peter Revsbech, Klaus Koren","doi":"10.1021/acs.analchem.4c05994","DOIUrl":null,"url":null,"abstract":"The accurate measurement of total ammonia nitrogen (TAN) and free ammonia is crucial for various environmental, biomedical and industrial applications. We present a novel integrated system combining electrochemical water splitting with ammonia optodes to simultaneously measure TAN and free ammonia. Water electrolysis induces localized pH shifts, altering the ammonia speciation in the sample solution: an increase in pH near the cathode leads to conversion of NH<sub>4</sub><sup>+</sup> to NH<sub>3</sub>, enabling the measurement of TAN. Concurrently, a decrease in pH near the anode reduces the NH<sub>3</sub> concentration to zero, enabling real-time zero calibration. In areas unaffected by these pH changes, the optode readout can effectively measure free NH<sub>3</sub>. The system demonstrates a measurement range of 0–300 mg·L<sup>–1</sup> for both TAN and NH<sub>3</sub>, with a complete measurement cycle requiring only 6 min. The method was validated through the analysis of urine samples, showcasing its potential for real-time monitoring in clinical and environmental settings. The electrochemical speciation shifting allows for precise TAN measurement, while the zero-point calibration provided by the anode enhances the method’s robustness and reliability. Overall, this study introduces a versatile and efficient approach for the simultaneous determination of TAN and NH<sub>3</sub>, offering significant improvements in speed and operational simplicity.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"21 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c05994","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The accurate measurement of total ammonia nitrogen (TAN) and free ammonia is crucial for various environmental, biomedical and industrial applications. We present a novel integrated system combining electrochemical water splitting with ammonia optodes to simultaneously measure TAN and free ammonia. Water electrolysis induces localized pH shifts, altering the ammonia speciation in the sample solution: an increase in pH near the cathode leads to conversion of NH4+ to NH3, enabling the measurement of TAN. Concurrently, a decrease in pH near the anode reduces the NH3 concentration to zero, enabling real-time zero calibration. In areas unaffected by these pH changes, the optode readout can effectively measure free NH3. The system demonstrates a measurement range of 0–300 mg·L–1 for both TAN and NH3, with a complete measurement cycle requiring only 6 min. The method was validated through the analysis of urine samples, showcasing its potential for real-time monitoring in clinical and environmental settings. The electrochemical speciation shifting allows for precise TAN measurement, while the zero-point calibration provided by the anode enhances the method’s robustness and reliability. Overall, this study introduces a versatile and efficient approach for the simultaneous determination of TAN and NH3, offering significant improvements in speed and operational simplicity.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信