Collaborative optimization scheduling strategy for HVAC with a three-layer optimization architecture

IF 6.6 2区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY
Yalun Zhu , Ming Wang , Dongrun Yang , Mingyuan Wang , Qianchuan Zhao , Xuehan Zheng , He Gao
{"title":"Collaborative optimization scheduling strategy for HVAC with a three-layer optimization architecture","authors":"Yalun Zhu ,&nbsp;Ming Wang ,&nbsp;Dongrun Yang ,&nbsp;Mingyuan Wang ,&nbsp;Qianchuan Zhao ,&nbsp;Xuehan Zheng ,&nbsp;He Gao","doi":"10.1016/j.enbuild.2025.115565","DOIUrl":null,"url":null,"abstract":"<div><div>Heating, ventilation, and air conditioning (HVAC) systems with different terminal devices can achieve the synergistic effects of multiple heat exchange methods. However, ineffective scheduling strategies for terminal modes during operation hinder cooling (or heating) performance and energy efficiency improvements. Multi-terminal system optimization has the characteristics of multi-variable and multi-objective challenge, which involves a complex coupling problem consisting of condition selection among different decision variables and interference of the same variable to different targets. Single-layer models struggle with coupling interference, while two-layer models only partially address coupling issues. A three-layer optimization architecture is proposed to decouple terminal mode selection from continuous parameter optimization, enhancing scheduling strategies for multi-terminal cooperative operation. And convection-radiation combined cooling system for air-cooled chiller is used as an example to validate the impact of the three-layer optimization architecture on thermal comfort and energy efficiency. The architecture optimizes terminal modes, chilled water flow rates, supply water temperatures, and air supply flow rates for each time period, while minimizing the influence of variable coupling. Additionally, four scheduling strategies are selected for experimental comparison, analyzing the variations in indoor temperature and power consumption to calculate the energy cost and thermal comfort cost for each strategy. The results show that, compared to the other four strategies, the scheduling strategy based on the three-layer optimization architecture can reduce energy costs by 1 % to 45 % and thermal comfort costs by 70 % to 94 %. This architecture enhances the performance of different terminal devices in a coordinated operation process within the HVAC system.</div></div>","PeriodicalId":11641,"journal":{"name":"Energy and Buildings","volume":"335 ","pages":"Article 115565"},"PeriodicalIF":6.6000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy and Buildings","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378778825002956","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Heating, ventilation, and air conditioning (HVAC) systems with different terminal devices can achieve the synergistic effects of multiple heat exchange methods. However, ineffective scheduling strategies for terminal modes during operation hinder cooling (or heating) performance and energy efficiency improvements. Multi-terminal system optimization has the characteristics of multi-variable and multi-objective challenge, which involves a complex coupling problem consisting of condition selection among different decision variables and interference of the same variable to different targets. Single-layer models struggle with coupling interference, while two-layer models only partially address coupling issues. A three-layer optimization architecture is proposed to decouple terminal mode selection from continuous parameter optimization, enhancing scheduling strategies for multi-terminal cooperative operation. And convection-radiation combined cooling system for air-cooled chiller is used as an example to validate the impact of the three-layer optimization architecture on thermal comfort and energy efficiency. The architecture optimizes terminal modes, chilled water flow rates, supply water temperatures, and air supply flow rates for each time period, while minimizing the influence of variable coupling. Additionally, four scheduling strategies are selected for experimental comparison, analyzing the variations in indoor temperature and power consumption to calculate the energy cost and thermal comfort cost for each strategy. The results show that, compared to the other four strategies, the scheduling strategy based on the three-layer optimization architecture can reduce energy costs by 1 % to 45 % and thermal comfort costs by 70 % to 94 %. This architecture enhances the performance of different terminal devices in a coordinated operation process within the HVAC system.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Energy and Buildings
Energy and Buildings 工程技术-工程:土木
CiteScore
12.70
自引率
11.90%
发文量
863
审稿时长
38 days
期刊介绍: An international journal devoted to investigations of energy use and efficiency in buildings Energy and Buildings is an international journal publishing articles with explicit links to energy use in buildings. The aim is to present new research results, and new proven practice aimed at reducing the energy needs of a building and improving indoor environment quality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信