Artificial Intelligence Versus Rules-Based Approach for Segmenting NonPerfusion Area in a DRCR Retina Network Optical Coherence Tomography Angiography Dataset.

IF 5 2区 医学 Q1 OPHTHALMOLOGY
Tristan T Hormel, Wesley T Beaulieu, Jie Wang, Jennifer K Sun, Yali Jia
{"title":"Artificial Intelligence Versus Rules-Based Approach for Segmenting NonPerfusion Area in a DRCR Retina Network Optical Coherence Tomography Angiography Dataset.","authors":"Tristan T Hormel, Wesley T Beaulieu, Jie Wang, Jennifer K Sun, Yali Jia","doi":"10.1167/iovs.66.3.22","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Loss of retinal perfusion is associated with both onset and worsening of diabetic retinopathy (DR). Optical coherence tomography angiography is a noninvasive method for measuring the nonperfusion area (NPA) and has promise as a scalable screening tool. This study compares two optical coherence tomography angiography algorithms for quantifying NPA.</p><p><strong>Methods: </strong>Adults with (N = 101) and without (N = 274) DR were recruited from 20 U.S. sites. We collected 3 × 3-mm macular scans using an Optovue RTVue-XR. Rules-based (RB) and deep-learning-based artificial intelligence (AI) algorithms were used to segment the NPA into four anatomical slabs. For comparison, a subset of scans (n = 50) NPA was graded manually.</p><p><strong>Results: </strong>The AI method outperformed the RB method in intersection over union, recall, and F1 score, but the RB method has better precision relative to manual grading in all anatomical slabs (all P ≤ 0.001). The AI method had a stronger rank correlation with Early Treatment of Diabetic Retinopathy Study DR severity than the RB method in all slabs (all P < 0.001). NPAs graded using the AI method had a greater area under the receiver operating characteristic curve for diagnosing referable DR than the RB method in the superficial vascular complex, intermediate capillary plexus, and combined inner retina (all P ≤ 0.001), but not in the deep capillary plexus (P = 0.92).</p><p><strong>Conclusions: </strong>Our results indicate that output from the AI-based method agrees better with manual grading and can better distinguish between clinically relevant DR severity levels than a RB approach using most plexuses.</p>","PeriodicalId":14620,"journal":{"name":"Investigative ophthalmology & visual science","volume":"66 3","pages":"22"},"PeriodicalIF":5.0000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11905605/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative ophthalmology & visual science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1167/iovs.66.3.22","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Loss of retinal perfusion is associated with both onset and worsening of diabetic retinopathy (DR). Optical coherence tomography angiography is a noninvasive method for measuring the nonperfusion area (NPA) and has promise as a scalable screening tool. This study compares two optical coherence tomography angiography algorithms for quantifying NPA.

Methods: Adults with (N = 101) and without (N = 274) DR were recruited from 20 U.S. sites. We collected 3 × 3-mm macular scans using an Optovue RTVue-XR. Rules-based (RB) and deep-learning-based artificial intelligence (AI) algorithms were used to segment the NPA into four anatomical slabs. For comparison, a subset of scans (n = 50) NPA was graded manually.

Results: The AI method outperformed the RB method in intersection over union, recall, and F1 score, but the RB method has better precision relative to manual grading in all anatomical slabs (all P ≤ 0.001). The AI method had a stronger rank correlation with Early Treatment of Diabetic Retinopathy Study DR severity than the RB method in all slabs (all P < 0.001). NPAs graded using the AI method had a greater area under the receiver operating characteristic curve for diagnosing referable DR than the RB method in the superficial vascular complex, intermediate capillary plexus, and combined inner retina (all P ≤ 0.001), but not in the deep capillary plexus (P = 0.92).

Conclusions: Our results indicate that output from the AI-based method agrees better with manual grading and can better distinguish between clinically relevant DR severity levels than a RB approach using most plexuses.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.90
自引率
4.50%
发文量
339
审稿时长
1 months
期刊介绍: Investigative Ophthalmology & Visual Science (IOVS), published as ready online, is a peer-reviewed academic journal of the Association for Research in Vision and Ophthalmology (ARVO). IOVS features original research, mostly pertaining to clinical and laboratory ophthalmology and vision research in general.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信