Co-Estimating Estradiol Valerate and Medroxyprogesterone Acetate in a Combined Hormonal Product: A Novel Short Runtime UPLC Method.

Erdal Dinç, Adem Mert
{"title":"Co-Estimating Estradiol Valerate and Medroxyprogesterone Acetate in a Combined Hormonal Product: A Novel Short Runtime UPLC Method.","authors":"Erdal Dinç, Adem Mert","doi":"10.1093/jaoacint/qsaf016","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hormones regulate growth, development, and reproductive functions. While deficiencies can lead to various health problems, excessive intake may cause metabolic disorders and side effects. Therefore, there is a need to develop new, reliable, and economical methods for quality control and accurate analysis of hormones in tablets used for hormone replacement therapy.</p><p><strong>Objective: </strong>To develop a novel, reliable, and cost-effective, ultra-performance liquid chromatography (UPLC) method for accurately quantifying estradiol valerate (EV) and medroxyprogesterone acetate (MPG) in hormone replacement therapy tablets.</p><p><strong>Method: </strong>Chromatographic separation of EV and MPG was achieved using an ACQUITY UPLC BEH C18 (1.7 μm, 2.1 mm × 100 mm) column and a mixture containing water (6%), acetonitrile (44%), methanol (42%), and 0.10 M phosphate buffer (8%, pH = 2.14). Chromatographic detection was accomplished at 280.0 nm for EV and 240.0 nm for MPG, with a flow rate of 0.34 mL/min at a column temperature of 40 °C. The method's validity was assessed using individual and spiked sample analyses.</p><p><strong>Results: </strong>The validated UPLC method offered an alternative procedure to quantify EV and MPG in commercial hormone tablets. This method demonstrated highly accurate, and precise analytic results with a short retention and low cost. The measured concentrations of EV and MPG in the tablet samples were found within the expected ranges, confirming the method's suitability for reliable hormone quantification in commercial tablets.</p><p><strong>Highlights: </strong>This study introduces the first UPLC-PDA method for analyzing EV and MPG in a commercial hormone formulation. The method showed excellent assay results in the analysis of real samples.</p>","PeriodicalId":94064,"journal":{"name":"Journal of AOAC International","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AOAC International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jaoacint/qsaf016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Hormones regulate growth, development, and reproductive functions. While deficiencies can lead to various health problems, excessive intake may cause metabolic disorders and side effects. Therefore, there is a need to develop new, reliable, and economical methods for quality control and accurate analysis of hormones in tablets used for hormone replacement therapy.

Objective: To develop a novel, reliable, and cost-effective, ultra-performance liquid chromatography (UPLC) method for accurately quantifying estradiol valerate (EV) and medroxyprogesterone acetate (MPG) in hormone replacement therapy tablets.

Method: Chromatographic separation of EV and MPG was achieved using an ACQUITY UPLC BEH C18 (1.7 μm, 2.1 mm × 100 mm) column and a mixture containing water (6%), acetonitrile (44%), methanol (42%), and 0.10 M phosphate buffer (8%, pH = 2.14). Chromatographic detection was accomplished at 280.0 nm for EV and 240.0 nm for MPG, with a flow rate of 0.34 mL/min at a column temperature of 40 °C. The method's validity was assessed using individual and spiked sample analyses.

Results: The validated UPLC method offered an alternative procedure to quantify EV and MPG in commercial hormone tablets. This method demonstrated highly accurate, and precise analytic results with a short retention and low cost. The measured concentrations of EV and MPG in the tablet samples were found within the expected ranges, confirming the method's suitability for reliable hormone quantification in commercial tablets.

Highlights: This study introduces the first UPLC-PDA method for analyzing EV and MPG in a commercial hormone formulation. The method showed excellent assay results in the analysis of real samples.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信