Development of a femtosecond analytical electron microscopy based on a Schottky field emission transmission electron microscope.

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION
Shaozheng Ji, Jiangteng Guo, Zefang Li, Ling Tong, Junqing Guo, Jingchao Liu, Ying Deng, Can Liu, Zepeng Sun, Xiang Chen, Cuntao Gao, Fang Liu, Min Feng, Xuewen Fu
{"title":"Development of a femtosecond analytical electron microscopy based on a Schottky field emission transmission electron microscope.","authors":"Shaozheng Ji, Jiangteng Guo, Zefang Li, Ling Tong, Junqing Guo, Jingchao Liu, Ying Deng, Can Liu, Zepeng Sun, Xiang Chen, Cuntao Gao, Fang Liu, Min Feng, Xuewen Fu","doi":"10.1063/5.0226913","DOIUrl":null,"url":null,"abstract":"<p><p>Ultrafast transmission electron microscopy (UTEM) has gained wide applications in the nanoscale dynamics with femtosecond, even attosecond, resolution. The instrument development is still in progress to satisfy the various applications. At Nankai University, we built an UTEM with a laser-driven Schottky field emitter based on a field emission TEM (Talos200i) of Thermo Fisher Scientific. This study comprehensively examines the performance of the UTEM, including the continuous mode and ultrafast photoemission mode. The investigation focuses on optimizing brightness, temporal resolution, energy dispersion, and stability in ultrafast photoemission mode, achieving a temporal resolution of ∼200 fs and an energy dispersion of 0.7 eV with excellent stability through careful adjustments of laser parameters and equipment settings. In scanning transmission electron microscopy mode, the beam size of the photoemission mode is ∼1.4 nm at specific settings with potential for further improvement. As application examples, we illustrate the results of photoinduced structural dynamics of gold film and MoS2 thin flake by ultrafast electron diffraction. We also report the polarization dependent optical interference pattern characterized by the photoinduced near field microscopy effect in a silicon thin film sample prepared by the focused ion beam method. These findings provide valuable insights for researchers aiming to leverage the UTEM's capabilities for advanced electron microscopy applications and pave the way for future advancements in UTEM technology.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"96 3","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0226913","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Ultrafast transmission electron microscopy (UTEM) has gained wide applications in the nanoscale dynamics with femtosecond, even attosecond, resolution. The instrument development is still in progress to satisfy the various applications. At Nankai University, we built an UTEM with a laser-driven Schottky field emitter based on a field emission TEM (Talos200i) of Thermo Fisher Scientific. This study comprehensively examines the performance of the UTEM, including the continuous mode and ultrafast photoemission mode. The investigation focuses on optimizing brightness, temporal resolution, energy dispersion, and stability in ultrafast photoemission mode, achieving a temporal resolution of ∼200 fs and an energy dispersion of 0.7 eV with excellent stability through careful adjustments of laser parameters and equipment settings. In scanning transmission electron microscopy mode, the beam size of the photoemission mode is ∼1.4 nm at specific settings with potential for further improvement. As application examples, we illustrate the results of photoinduced structural dynamics of gold film and MoS2 thin flake by ultrafast electron diffraction. We also report the polarization dependent optical interference pattern characterized by the photoinduced near field microscopy effect in a silicon thin film sample prepared by the focused ion beam method. These findings provide valuable insights for researchers aiming to leverage the UTEM's capabilities for advanced electron microscopy applications and pave the way for future advancements in UTEM technology.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信