{"title":"Radiomics and deep learning features of pericoronary adipose tissue on non-contrast computerized tomography for predicting non-calcified plaques.","authors":"Junli Yu, Yan Ding, Li Wang, Shunxin Hu, Ning Dong, Jiangnan Sheng, Yingna Ren, Ziyue Wang","doi":"10.1177/08953996241292476","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Inflammation of coronary arterial plaque is considered a key factor in the development of coronary heart disease. Early the plaque detection and timely treatment of the atherosclerosis could effectively reduce the risk of cardiovascular events. However, there is no study combining radiomics with deep learning techniques to predict non-calcified plaques (NCP) in coronary artery at present.</p><p><strong>Objective: </strong>To investigate the value of combination of radiomics and deep learning features based on non-contrast computerized tomography (CT) scans of pericoronary adipose tissue (PCAT), integrating with clinical risk factors of patients, in identifying coronary inflammation and predicting the presence of NCP.</p><p><strong>Methods: </strong>The clinical and imaging data of 353 patients were analyzed. The region of interest (ROI) of PCAT was manually outlined on non-contrast CT scan images, like coronary CT calcium score sequential images, then the radiomics and deep learning features in ROIs were extracted respectively. In training set (Center 1), after performing feature selection, radiomics and deep learning feature models were established, meanwhile, clinical models were built. Finally, combined models were developed out via integrating clinical, radiomics, and deep learning features. The predictive performance of the four feature model groups (clinical, radiomics, deep learning, and three combination) was assessed by seven different machine learning models through generation of receiver operating characteristic curves (ROC) and the calculation of area under the curve (AUC), sensitivity, specificity, and accuracy. Furthermore, the predictive performance of each model was validated in an external validation set (Center 2).</p><p><strong>Results: </strong>For the single model comparation, eXtreme Gradient Boosting (XGBoost) showed the best performance among the clinical model group in the validation set. And Random Forest (RF) exhibited the best indicative performance not only among the radiomics feature group but also in the deep learning feature model group. What's more, among the combined model group, RF still displayed the best predictive performance, with the value of AUC, sensitivity, specificity, and accuracy in the validation set are 0.963, 0.857, 0.929, and 0.905.</p><p><strong>Conclusion: </strong>The RF model in the combined model group based on non-contrast CT scan PCAT can predict the presence of NCP more accurately and has the potential for preliminary screening of the NCP.</p>","PeriodicalId":49948,"journal":{"name":"Journal of X-Ray Science and Technology","volume":" ","pages":"96-108"},"PeriodicalIF":1.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of X-Ray Science and Technology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08953996241292476","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/18 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Inflammation of coronary arterial plaque is considered a key factor in the development of coronary heart disease. Early the plaque detection and timely treatment of the atherosclerosis could effectively reduce the risk of cardiovascular events. However, there is no study combining radiomics with deep learning techniques to predict non-calcified plaques (NCP) in coronary artery at present.

Objective: To investigate the value of combination of radiomics and deep learning features based on non-contrast computerized tomography (CT) scans of pericoronary adipose tissue (PCAT), integrating with clinical risk factors of patients, in identifying coronary inflammation and predicting the presence of NCP.

Methods: The clinical and imaging data of 353 patients were analyzed. The region of interest (ROI) of PCAT was manually outlined on non-contrast CT scan images, like coronary CT calcium score sequential images, then the radiomics and deep learning features in ROIs were extracted respectively. In training set (Center 1), after performing feature selection, radiomics and deep learning feature models were established, meanwhile, clinical models were built. Finally, combined models were developed out via integrating clinical, radiomics, and deep learning features. The predictive performance of the four feature model groups (clinical, radiomics, deep learning, and three combination) was assessed by seven different machine learning models through generation of receiver operating characteristic curves (ROC) and the calculation of area under the curve (AUC), sensitivity, specificity, and accuracy. Furthermore, the predictive performance of each model was validated in an external validation set (Center 2).

Results: For the single model comparation, eXtreme Gradient Boosting (XGBoost) showed the best performance among the clinical model group in the validation set. And Random Forest (RF) exhibited the best indicative performance not only among the radiomics feature group but also in the deep learning feature model group. What's more, among the combined model group, RF still displayed the best predictive performance, with the value of AUC, sensitivity, specificity, and accuracy in the validation set are 0.963, 0.857, 0.929, and 0.905.

Conclusion: The RF model in the combined model group based on non-contrast CT scan PCAT can predict the presence of NCP more accurately and has the potential for preliminary screening of the NCP.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.90
自引率
23.30%
发文量
150
审稿时长
3 months
期刊介绍: Research areas within the scope of the journal include: Interaction of x-rays with matter: x-ray phenomena, biological effects of radiation, radiation safety and optical constants X-ray sources: x-rays from synchrotrons, x-ray lasers, plasmas, and other sources, conventional or unconventional Optical elements: grazing incidence optics, multilayer mirrors, zone plates, gratings, other diffraction optics Optical instruments: interferometers, spectrometers, microscopes, telescopes, microprobes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信