Development of a high-stability FHD (total-field F, horizontal component H, and declination D) geomagnetic vector magnetometer based on bias and compensation fields.

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION
Haihua Ju, Zhong Xia, Jian Ge, Cen Zhang, Le Zhang, Bin Li, Jia Dai
{"title":"Development of a high-stability FHD (total-field F, horizontal component H, and declination D) geomagnetic vector magnetometer based on bias and compensation fields.","authors":"Haihua Ju, Zhong Xia, Jian Ge, Cen Zhang, Le Zhang, Bin Li, Jia Dai","doi":"10.1063/5.0215329","DOIUrl":null,"url":null,"abstract":"<p><p>Geomagnetic vector measurement can obtain more geomagnetic information, which is one of the main development directions of geomagnetic measurement. To date, the magnetic flux gate magnetometer is the main tool for geomagnetic vector measurement; however, its drift issue cannot be ignored. To address this issue, we propose a geomagnetic vector measurement method based on bias and compensation fields and then develop a high-stability FHD (total-field F, horizontal component H, and declination D) vector magnetometer based on a proton sensor and a magnetic field generator. In addition, a dedicated experimental platform is constructed to verify the performance of the developed magnetometer in a geomagnetic station. Compared to the flux gate magnetometer, the experimental results indicate that the fourth-order differential noise of the declination D, horizontal component H, and vertical component Z are 1″, 0.27, and 0.15 nT, respectively, which are all lower than those of the flux gate magnetometer. In addition, the horizontal component H and vertical component Z of the flux gate magnetometer indicate more than 30 and 60 nT startup drift, respectively; in contrast, the proposed FHD magnetometer shows an excellent stability during a 16 h observation time.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"96 2","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0215329","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Geomagnetic vector measurement can obtain more geomagnetic information, which is one of the main development directions of geomagnetic measurement. To date, the magnetic flux gate magnetometer is the main tool for geomagnetic vector measurement; however, its drift issue cannot be ignored. To address this issue, we propose a geomagnetic vector measurement method based on bias and compensation fields and then develop a high-stability FHD (total-field F, horizontal component H, and declination D) vector magnetometer based on a proton sensor and a magnetic field generator. In addition, a dedicated experimental platform is constructed to verify the performance of the developed magnetometer in a geomagnetic station. Compared to the flux gate magnetometer, the experimental results indicate that the fourth-order differential noise of the declination D, horizontal component H, and vertical component Z are 1″, 0.27, and 0.15 nT, respectively, which are all lower than those of the flux gate magnetometer. In addition, the horizontal component H and vertical component Z of the flux gate magnetometer indicate more than 30 and 60 nT startup drift, respectively; in contrast, the proposed FHD magnetometer shows an excellent stability during a 16 h observation time.

地磁矢量测量可以获得更多的地磁信息,是地磁测量的主要发展方向之一。迄今为止,磁通门磁力计是地磁矢量测量的主要工具,但其漂移问题不容忽视。针对这一问题,我们提出了一种基于偏置场和补偿场的地磁矢量测量方法,然后开发了一种基于质子传感器和磁场发生器的高稳定性 FHD(全场 F、水平分量 H 和偏角 D)矢量磁力计。此外,还构建了一个专用实验平台,以验证所开发的磁力计在地磁站中的性能。实验结果表明,与磁通门磁力计相比,偏角 D、水平分量 H 和垂直分量 Z 的四阶差分噪声分别为 1″、0.27 和 0.15 nT,均低于磁通门磁力计。此外,磁通门磁力计的水平分量 H 和垂直分量 Z 分别显示出超过 30 nT 和 60 nT 的启动漂移;相比之下,拟议的 FHD 磁力计在 16 h 的观测时间内显示出极佳的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信