{"title":"Polarization-independent ultra-sensitive graphene sensor for the detection of prostate-specific antigen","authors":"Yousef Rafighirani, Javad Javidan, Hamid Heidarzadeh","doi":"10.1016/j.ijleo.2024.172196","DOIUrl":null,"url":null,"abstract":"<div><div>This study presents a three-band absorbent structure based on cut graphene, which has been used as a biosensor for the detection of prostate-specific antigen (PSA) due to the tunability of the resonance frequency of graphene and the polarization-independent capability of the proposed structure. The sensor is composed of three layers: a copper substrate with a conductivity of 5.831 ×<span><math><msup><mrow><mn>10</mn></mrow><mrow><mn>7</mn></mrow></msup></math></span>, a silicon dioxide (SiO₂) dielectric layer with a permittivity of 3.9, and a graphene layer with strategic cuts to enhance absorption. The performance of the proposed structure was evaluated by measuring its absorption at three terahertz frequency bands: 3.9 THz, 8.52 THz, and 11.83 THz, achieving absorption values of 99.65 %, 99.25 %, and 99.78 %, respectively. These high absorption rates make the sensor an excellent candidate for biosensing applications, particularly for detecting PSA in clinical samples. By testing the sensor with analytes containing PSA at 100, 200, 300, and 400 PM concentrations, the refractive index values were 1.3477, 1.3654, 1.3831, and 1.4008, respectively. When the analyte layer is placed on the three-band absorber structure, the peak shift is absorbed, enabling the detection of the desired analyte. The proposed structure demonstrated remarkable sensitivity, achieving 2638.4 GHz/RIU at a refractive index of 1.3831 and a frequency of 11.451 THz. This high sensitivity is particularly advantageous for detecting low concentrations of analytes. Such a sensor has great potential for enhancing the detection of biomarkers. These findings highlight the sensor's potential for high-sensitivity PSA detection, offering a valuable tool for early prostate cancer diagnosis and screening.</div></div>","PeriodicalId":19513,"journal":{"name":"Optik","volume":"322 ","pages":"Article 172196"},"PeriodicalIF":3.1000,"publicationDate":"2024-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optik","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0030402624005953","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
This study presents a three-band absorbent structure based on cut graphene, which has been used as a biosensor for the detection of prostate-specific antigen (PSA) due to the tunability of the resonance frequency of graphene and the polarization-independent capability of the proposed structure. The sensor is composed of three layers: a copper substrate with a conductivity of 5.831 ×, a silicon dioxide (SiO₂) dielectric layer with a permittivity of 3.9, and a graphene layer with strategic cuts to enhance absorption. The performance of the proposed structure was evaluated by measuring its absorption at three terahertz frequency bands: 3.9 THz, 8.52 THz, and 11.83 THz, achieving absorption values of 99.65 %, 99.25 %, and 99.78 %, respectively. These high absorption rates make the sensor an excellent candidate for biosensing applications, particularly for detecting PSA in clinical samples. By testing the sensor with analytes containing PSA at 100, 200, 300, and 400 PM concentrations, the refractive index values were 1.3477, 1.3654, 1.3831, and 1.4008, respectively. When the analyte layer is placed on the three-band absorber structure, the peak shift is absorbed, enabling the detection of the desired analyte. The proposed structure demonstrated remarkable sensitivity, achieving 2638.4 GHz/RIU at a refractive index of 1.3831 and a frequency of 11.451 THz. This high sensitivity is particularly advantageous for detecting low concentrations of analytes. Such a sensor has great potential for enhancing the detection of biomarkers. These findings highlight the sensor's potential for high-sensitivity PSA detection, offering a valuable tool for early prostate cancer diagnosis and screening.
期刊介绍:
Optik publishes articles on all subjects related to light and electron optics and offers a survey on the state of research and technical development within the following fields:
Optics:
-Optics design, geometrical and beam optics, wave optics-
Optical and micro-optical components, diffractive optics, devices and systems-
Photoelectric and optoelectronic devices-
Optical properties of materials, nonlinear optics, wave propagation and transmission in homogeneous and inhomogeneous materials-
Information optics, image formation and processing, holographic techniques, microscopes and spectrometer techniques, and image analysis-
Optical testing and measuring techniques-
Optical communication and computing-
Physiological optics-
As well as other related topics.