Polarization-independent ultra-sensitive graphene sensor for the detection of prostate-specific antigen

IF 3.1 3区 物理与天体物理 Q2 Engineering
Optik Pub Date : 2024-12-30 DOI:10.1016/j.ijleo.2024.172196
Yousef Rafighirani, Javad Javidan, Hamid Heidarzadeh
{"title":"Polarization-independent ultra-sensitive graphene sensor for the detection of prostate-specific antigen","authors":"Yousef Rafighirani,&nbsp;Javad Javidan,&nbsp;Hamid Heidarzadeh","doi":"10.1016/j.ijleo.2024.172196","DOIUrl":null,"url":null,"abstract":"<div><div>This study presents a three-band absorbent structure based on cut graphene, which has been used as a biosensor for the detection of prostate-specific antigen (PSA) due to the tunability of the resonance frequency of graphene and the polarization-independent capability of the proposed structure. The sensor is composed of three layers: a copper substrate with a conductivity of 5.831 ×<span><math><msup><mrow><mn>10</mn></mrow><mrow><mn>7</mn></mrow></msup></math></span>, a silicon dioxide (SiO₂) dielectric layer with a permittivity of 3.9, and a graphene layer with strategic cuts to enhance absorption. The performance of the proposed structure was evaluated by measuring its absorption at three terahertz frequency bands: 3.9 THz, 8.52 THz, and 11.83 THz, achieving absorption values of 99.65 %, 99.25 %, and 99.78 %, respectively. These high absorption rates make the sensor an excellent candidate for biosensing applications, particularly for detecting PSA in clinical samples. By testing the sensor with analytes containing PSA at 100, 200, 300, and 400 PM concentrations, the refractive index values were 1.3477, 1.3654, 1.3831, and 1.4008, respectively. When the analyte layer is placed on the three-band absorber structure, the peak shift is absorbed, enabling the detection of the desired analyte. The proposed structure demonstrated remarkable sensitivity, achieving 2638.4 GHz/RIU at a refractive index of 1.3831 and a frequency of 11.451 THz. This high sensitivity is particularly advantageous for detecting low concentrations of analytes. Such a sensor has great potential for enhancing the detection of biomarkers. These findings highlight the sensor's potential for high-sensitivity PSA detection, offering a valuable tool for early prostate cancer diagnosis and screening.</div></div>","PeriodicalId":19513,"journal":{"name":"Optik","volume":"322 ","pages":"Article 172196"},"PeriodicalIF":3.1000,"publicationDate":"2024-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optik","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0030402624005953","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents a three-band absorbent structure based on cut graphene, which has been used as a biosensor for the detection of prostate-specific antigen (PSA) due to the tunability of the resonance frequency of graphene and the polarization-independent capability of the proposed structure. The sensor is composed of three layers: a copper substrate with a conductivity of 5.831 ×107, a silicon dioxide (SiO₂) dielectric layer with a permittivity of 3.9, and a graphene layer with strategic cuts to enhance absorption. The performance of the proposed structure was evaluated by measuring its absorption at three terahertz frequency bands: 3.9 THz, 8.52 THz, and 11.83 THz, achieving absorption values of 99.65 %, 99.25 %, and 99.78 %, respectively. These high absorption rates make the sensor an excellent candidate for biosensing applications, particularly for detecting PSA in clinical samples. By testing the sensor with analytes containing PSA at 100, 200, 300, and 400 PM concentrations, the refractive index values were 1.3477, 1.3654, 1.3831, and 1.4008, respectively. When the analyte layer is placed on the three-band absorber structure, the peak shift is absorbed, enabling the detection of the desired analyte. The proposed structure demonstrated remarkable sensitivity, achieving 2638.4 GHz/RIU at a refractive index of 1.3831 and a frequency of 11.451 THz. This high sensitivity is particularly advantageous for detecting low concentrations of analytes. Such a sensor has great potential for enhancing the detection of biomarkers. These findings highlight the sensor's potential for high-sensitivity PSA detection, offering a valuable tool for early prostate cancer diagnosis and screening.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Optik
Optik 物理-光学
CiteScore
6.90
自引率
12.90%
发文量
1471
审稿时长
46 days
期刊介绍: Optik publishes articles on all subjects related to light and electron optics and offers a survey on the state of research and technical development within the following fields: Optics: -Optics design, geometrical and beam optics, wave optics- Optical and micro-optical components, diffractive optics, devices and systems- Photoelectric and optoelectronic devices- Optical properties of materials, nonlinear optics, wave propagation and transmission in homogeneous and inhomogeneous materials- Information optics, image formation and processing, holographic techniques, microscopes and spectrometer techniques, and image analysis- Optical testing and measuring techniques- Optical communication and computing- Physiological optics- As well as other related topics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信