Continuous Delivery of Hyperpolarized Xenon-129 Gas Using a “Stopped-Flow” Clinical-Scale Cryogen-Free Hyperpolarizer

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Md Raduanul H. Chowdhury, Clementinah Oladun, Firoz Ahmed, Nuwandi M. Ariyasingha, Abubakar Abdurraheem, Faisal Asif, Joseph Gyesi, Panayiotis Nikolaou, Michael J. Barlow, Anton Shcherbakov, Nathan A. Rudman, Ivan J. Dmochowski, Boyd M. Goodson, Eduard Y. Chekmenev
{"title":"Continuous Delivery of Hyperpolarized Xenon-129 Gas Using a “Stopped-Flow” Clinical-Scale Cryogen-Free Hyperpolarizer","authors":"Md Raduanul H. Chowdhury, Clementinah Oladun, Firoz Ahmed, Nuwandi M. Ariyasingha, Abubakar Abdurraheem, Faisal Asif, Joseph Gyesi, Panayiotis Nikolaou, Michael J. Barlow, Anton Shcherbakov, Nathan A. Rudman, Ivan J. Dmochowski, Boyd M. Goodson, Eduard Y. Chekmenev","doi":"10.1021/acs.analchem.4c05372","DOIUrl":null,"url":null,"abstract":"In 2022, the FDA approved hyperpolarized (HP) <sup>129</sup>Xe gas as an inhalable contrast agent for functional lung imaging. For clinical imaging, HP <sup>129</sup>Xe is usually given as a bolus inhalation. However, for preclinical applications (e.g., pulmonary imaging in small rodents), the continuous delivery of HP <sup>129</sup>Xe is greatly desired to enable MRI scanning under conditions of physiological continuous animal breathing patterns. Moreover, HP <sup>129</sup>Xe gas can be utilized for other applications including materials science and bioanalytical chemistry, where a continuous flow of hyperpolarized gas through an NMR sample over several minutes is also desired for sensing of <sup>129</sup>Xe inside an NMR spectrometer. <sup>129</sup>Xe is often hyperpolarized using continuous-flow spin-exchange optical pumping, which employs a lean (1–2%) mixture of Xe and a carrier gas (e.g., He and N<sub>2</sub>). The low Xe concentration in the produced output reduces the NMR detection sensitivity, and thus, Xe cryo-collection is typically employed to achieve near-100% pure gas-phase Xe before administration to the sample or subject. However, the need for cryo-collection undermines a key advantage of continuous-flow production, i.e., the continuous flowing in a hyperpolarizer HP <sup>129</sup>Xe gas is trapped inside the hyperpolarizer, and the produced HP <sup>129</sup>Xe gas is released at once when the production cycle (30–60 min) is completed. An alternative HP <sup>129</sup>Xe production technology employs a “stopped-flow” approach, where a batch of HP gas is hyperpolarized over time and quickly released from a hyperpolarizer. Here, a clinical-scale “stopped-flow” <sup>129</sup>Xe hyperpolarizer was employed to hyperpolarize a 1.3 L-atm batch of 50:50 Xe:N<sub>2</sub> gas mixture inside a glass cell with an ultralong lifetime of the HP <sup>129</sup>Xe state (<i>T</i><sub>1</sub> &gt; 2 h). The produced HP <sup>129</sup>Xe gas was slowly delivered into a 5 mm NMR tube via PEEK tubing under a wide range of gas flow rates: 3–180 standard cubic centimeters per minute (sccm). The polarization of the gas ejected from the hyperpolarizer was quantified using <i>in situ</i> low-field NMR polarimetry and additionally verified using a 0.35 T clinical MRI scanner. Continuous-flow delivery of HP <sup>129</sup>Xe was demonstrated for up to 15 min with a gas flow rate of 45–150 sccm over a 2.5-m length of PEEK tubing, suffering only small losses in <sup>129</sup>Xe polarization. These observations are additionally supported by <sup>129</sup>Xe relaxation measurements inside the PEEK tubing employed for gas delivery and the 5 mm NMR tube employed for polarimetry. <sup>129</sup>Xe polarization of 16–19% was obtained in the delivered gas, starting with an “in-polarizer” <sup>129</sup>Xe polarization of 19%. We envision that this method can be employed for on-demand cryogen-free delivery of hyperpolarized gas using “stopped-flow” <sup>129</sup>Xe hyperpolarizers for a broad range of applications, from preclinical imaging to biosensors, and to spectroscopy of materials surfaces.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"38 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c05372","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In 2022, the FDA approved hyperpolarized (HP) 129Xe gas as an inhalable contrast agent for functional lung imaging. For clinical imaging, HP 129Xe is usually given as a bolus inhalation. However, for preclinical applications (e.g., pulmonary imaging in small rodents), the continuous delivery of HP 129Xe is greatly desired to enable MRI scanning under conditions of physiological continuous animal breathing patterns. Moreover, HP 129Xe gas can be utilized for other applications including materials science and bioanalytical chemistry, where a continuous flow of hyperpolarized gas through an NMR sample over several minutes is also desired for sensing of 129Xe inside an NMR spectrometer. 129Xe is often hyperpolarized using continuous-flow spin-exchange optical pumping, which employs a lean (1–2%) mixture of Xe and a carrier gas (e.g., He and N2). The low Xe concentration in the produced output reduces the NMR detection sensitivity, and thus, Xe cryo-collection is typically employed to achieve near-100% pure gas-phase Xe before administration to the sample or subject. However, the need for cryo-collection undermines a key advantage of continuous-flow production, i.e., the continuous flowing in a hyperpolarizer HP 129Xe gas is trapped inside the hyperpolarizer, and the produced HP 129Xe gas is released at once when the production cycle (30–60 min) is completed. An alternative HP 129Xe production technology employs a “stopped-flow” approach, where a batch of HP gas is hyperpolarized over time and quickly released from a hyperpolarizer. Here, a clinical-scale “stopped-flow” 129Xe hyperpolarizer was employed to hyperpolarize a 1.3 L-atm batch of 50:50 Xe:N2 gas mixture inside a glass cell with an ultralong lifetime of the HP 129Xe state (T1 > 2 h). The produced HP 129Xe gas was slowly delivered into a 5 mm NMR tube via PEEK tubing under a wide range of gas flow rates: 3–180 standard cubic centimeters per minute (sccm). The polarization of the gas ejected from the hyperpolarizer was quantified using in situ low-field NMR polarimetry and additionally verified using a 0.35 T clinical MRI scanner. Continuous-flow delivery of HP 129Xe was demonstrated for up to 15 min with a gas flow rate of 45–150 sccm over a 2.5-m length of PEEK tubing, suffering only small losses in 129Xe polarization. These observations are additionally supported by 129Xe relaxation measurements inside the PEEK tubing employed for gas delivery and the 5 mm NMR tube employed for polarimetry. 129Xe polarization of 16–19% was obtained in the delivered gas, starting with an “in-polarizer” 129Xe polarization of 19%. We envision that this method can be employed for on-demand cryogen-free delivery of hyperpolarized gas using “stopped-flow” 129Xe hyperpolarizers for a broad range of applications, from preclinical imaging to biosensors, and to spectroscopy of materials surfaces.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信