Diagonal loading common spatial patterns with Pearson correlation coefficient based feature selection for efficient motor imagery classification.

IF 1.7 4区 医学 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
Hanaa S Ali, Asmaa I Ismail, El-Sayed M El-Rabaie, Fathi E Abd El-Samie
{"title":"Diagonal loading common spatial patterns with Pearson correlation coefficient based feature selection for efficient motor imagery classification.","authors":"Hanaa S Ali, Asmaa I Ismail, El-Sayed M El-Rabaie, Fathi E Abd El-Samie","doi":"10.1080/10255842.2025.2457122","DOIUrl":null,"url":null,"abstract":"<p><p>The conversion of a person's intentions into device commands through the use of brain-computer interface (BCI) is a feasible communication method for individuals with nervous system disorders. While common spatial pattern (CSP) is commonly used for feature extraction in BCIs, it has limitations. It is known for its susceptibility to noise and tendency to overfit. Moreover, high-dimensional, and irrelevant features can make it harder for a classifier to learn effectively. To address these challenges, exploring potential solutions is crucial. This paper introduces Regularized CSP with diagonal loading (DL-CSP) and Pearson correlation coefficient (PCC) based feature selection to extract the most discriminative motor imagery EEG (MI-EEG) features. Three classifiers in an ensemble are considered; bidirectional long short-term memory (Bi-LSTM), K-nearest neighbors (KNN) and naïve Bayes (NB). Decision level fusion through majority voting is exploited to leverage diverse perspectives and increase the overall system robustness. Experiments have been implemented using three publicly available datasets for MI classification; BCI competition IV-IIA (data-1), BCI Competition III-IVa (data-2), and a stroke patients' dataset (data-3). The accuracy achieved, according to the results, is 86.96% for data-1, 91.70% for data-2, and 85.75% for data-3. These percentages outperform the accuracy achieved by any state-of-the-art techniques.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":" ","pages":"1-15"},"PeriodicalIF":1.7000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2025.2457122","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

The conversion of a person's intentions into device commands through the use of brain-computer interface (BCI) is a feasible communication method for individuals with nervous system disorders. While common spatial pattern (CSP) is commonly used for feature extraction in BCIs, it has limitations. It is known for its susceptibility to noise and tendency to overfit. Moreover, high-dimensional, and irrelevant features can make it harder for a classifier to learn effectively. To address these challenges, exploring potential solutions is crucial. This paper introduces Regularized CSP with diagonal loading (DL-CSP) and Pearson correlation coefficient (PCC) based feature selection to extract the most discriminative motor imagery EEG (MI-EEG) features. Three classifiers in an ensemble are considered; bidirectional long short-term memory (Bi-LSTM), K-nearest neighbors (KNN) and naïve Bayes (NB). Decision level fusion through majority voting is exploited to leverage diverse perspectives and increase the overall system robustness. Experiments have been implemented using three publicly available datasets for MI classification; BCI competition IV-IIA (data-1), BCI Competition III-IVa (data-2), and a stroke patients' dataset (data-3). The accuracy achieved, according to the results, is 86.96% for data-1, 91.70% for data-2, and 85.75% for data-3. These percentages outperform the accuracy achieved by any state-of-the-art techniques.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
6.20%
发文量
179
审稿时长
4-8 weeks
期刊介绍: The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信