Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique.

IF 3.6 2区 医学 Q1 CLINICAL NEUROLOGY
Neurospine Pub Date : 2024-12-01 Epub Date: 2024-12-31 DOI:10.14245/ns.2449126.563
Yu-Chia Hsu, Hao-Chun Chuang, Wei-Lun Chang, Yuan-Fu Liu, Chao-Jui Chang, Yu-Meng Hsiao, Yi-Hung Huang, Keng-Chang Liu, Chien-Min Chen, Hyeun-Sung Kim, Cheng-Li Lin
{"title":"Innovative Nerve Root Protection in Full-Endoscopic Facet-Resecting Lumbar Interbody Fusion: Controlled Cage Glider Rotation Using the GUARD (Glider Used As a Rotary Device) Technique.","authors":"Yu-Chia Hsu, Hao-Chun Chuang, Wei-Lun Chang, Yuan-Fu Liu, Chao-Jui Chang, Yu-Meng Hsiao, Yi-Hung Huang, Keng-Chang Liu, Chien-Min Chen, Hyeun-Sung Kim, Cheng-Li Lin","doi":"10.14245/ns.2449126.563","DOIUrl":null,"url":null,"abstract":"<p><p>This video presents a case of L4-5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4-5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.</p>","PeriodicalId":19269,"journal":{"name":"Neurospine","volume":"21 4","pages":"1141-1148"},"PeriodicalIF":3.6000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11744537/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurospine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.14245/ns.2449126.563","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/31 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This video presents a case of L4-5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root. A 48-year-old woman with a 3-year history of progressive low back pain and bilateral lower extremity radiculopathy (right-sided predominance) was diagnosed with L4-5 unstable spondylolisthesis and spinal stenosis. After failure of conservative management, she underwent uniportal full-endoscopic facet-resecting transforaminal lumbar interbody fusion using the GUARD technique. Postoperatively, the patient experienced significant symptomatic improvement and resolution of radiculopathy, without any intraoperative nerve root injury or postoperative neurological deficits. This case demonstrates the effectiveness of the GUARD technique in reducing neurological complications and improving patient outcomes.

全内窥镜切除腰椎椎体间融合术中的创新神经根保护:使用GUARD(滑翔机用作旋转装置)技术控制滑翔机旋转。
本视频报道一例L4-5不稳定型腰椎滑脱,采用全内窥镜经椎间孔腰椎椎体间融合术(endo - tliff)治疗,强调使用GUARD(滑翔机用作旋转装置)技术保护神经根。这种创新的方法包括在插入椎笼之前控制滑翔机的旋转,以尽量减少神经根损伤的风险,神经根损伤是endotlif手术的一个重要并发症。GUARD技术在之前的尸体研究中得到了验证,通过保护神经根,可以提高笼插入时的安全性。一名48岁女性,患有3年进行性腰痛和双侧下肢神经根病(右侧为主),诊断为L4-5不稳定型腰椎滑脱和椎管狭窄。保守治疗失败后,患者采用GUARD技术行单门静脉全内窥镜切除椎间孔腰椎椎体间融合术。术后患者症状明显改善,神经根病得到缓解,术中无神经根损伤,术后无神经功能缺损。本病例证明了GUARD技术在减少神经系统并发症和改善患者预后方面的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Neurospine
Neurospine Multiple-
CiteScore
5.80
自引率
18.80%
发文量
93
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信