Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Heng Wang, Yufu Xu, Jingya Zhang, Xinyu Zhao, Zhaodong Zhang, Ke Chen
{"title":"Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell","authors":"Heng Wang, Yufu Xu, Jingya Zhang, Xinyu Zhao, Zhaodong Zhang, Ke Chen","doi":"10.1021/acs.analchem.4c05486","DOIUrl":null,"url":null,"abstract":"A linear spot-type multipass cell-enhanced fiber-optic photoacoustic gas microprobe is proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic signal, we designed the cross section of the photoacoustic tube as a slit with a height of 10 mm and a width of 1.5 mm. The volume of the gas chamber is only 210 μL. Through theoretical analysis and multiphysical field simulation, the photoacoustic intensity of the slit cross section is more than 6 times that of traditional circular cross section. A cantilever beam is integrated into the photoacoustic microprobe and forms a Fabry–Perot (FP) interferometer with an optical fiber, achieving enhanced photoacoustic detection. By adjusting the angle of the collimator, the light passes through the photoacoustic cell 26 times, and 13 linear spots are formed on the reflecting surface. The photoacoustic signal with multiple linear reflections is 12.4 times that of a single reflection. The gas enters the sensor in a freely diffused manner, and the response time of the sensing system is 54 s. When the averaging time is 400 s, the detection limit of the designed sensor for acetylene gas reaches 1.5 ppb. The minimum detectable absorption coefficient (α<sub>min</sub>) and the normalized noise equivalent absorption coefficient (NNEA) are 1.7 × 10<sup>–8</sup> cm<sup>–1</sup> and 1.9 × 10<sup>–9</sup> Wcm<sup>–1</sup>/Hz<sup>1/2</sup>, respectively.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"75 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2025-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c05486","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A linear spot-type multipass cell-enhanced fiber-optic photoacoustic gas microprobe is proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic signal, we designed the cross section of the photoacoustic tube as a slit with a height of 10 mm and a width of 1.5 mm. The volume of the gas chamber is only 210 μL. Through theoretical analysis and multiphysical field simulation, the photoacoustic intensity of the slit cross section is more than 6 times that of traditional circular cross section. A cantilever beam is integrated into the photoacoustic microprobe and forms a Fabry–Perot (FP) interferometer with an optical fiber, achieving enhanced photoacoustic detection. By adjusting the angle of the collimator, the light passes through the photoacoustic cell 26 times, and 13 linear spots are formed on the reflecting surface. The photoacoustic signal with multiple linear reflections is 12.4 times that of a single reflection. The gas enters the sensor in a freely diffused manner, and the response time of the sensing system is 54 s. When the averaging time is 400 s, the detection limit of the designed sensor for acetylene gas reaches 1.5 ppb. The minimum detectable absorption coefficient (αmin) and the normalized noise equivalent absorption coefficient (NNEA) are 1.7 × 10–8 cm–1 and 1.9 × 10–9 Wcm–1/Hz1/2, respectively.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信