Yasmin Liu, Rishi Pandey, Mary Jane McCarthy, Onyekachi Raymond
{"title":"Electrochemical Aptamer-Based Biosensors for Cocaine Detection in Human Saliva: Exploring Matrix Interference","authors":"Yasmin Liu, Rishi Pandey, Mary Jane McCarthy, Onyekachi Raymond","doi":"10.1021/acs.analchem.4c03423","DOIUrl":null,"url":null,"abstract":"Electrochemical aptamer-based biosensors (E-aptasensors) are emerging platforms for point-of-care (POC) detection of complex biofluids. Human saliva particularly offers a noninvasive matrix and unprecedented convenience for detecting illicit drugs, such as cocaine. However, the sensitivity of cocaine E-aptasensors is significantly compromised in saliva. Herein, we investigated the influence of salivary components on the sensing performance of a methylene blue (MB)-labeled classic cocaine aptamer by square-wave voltammetry (SWV), and in parallel, we report the development and optimization of a disposable E-aptasensor for cocaine detection fabricated by laser ablation. Cyclic voltammetry (CV), scanning electron microscopy (SEM), and atomic force microscopy (AFM) were used to study the cleanliness and surface topography of the disposable electrode surface. To enhance the sensing performance of the disposable platform, we developed a co-immobilization strategy by introducing both the target and 6-mercapto-1-hexanol (MCH) into the aptamer immobilization solution, achieving optimal sensing performance at the aptamer-to-MCH ratio of 1:100. In a buffer solution, we revealed that the aptasensor performs best at low ionic strength, the absence of multivalent ions, and neutral pH conditions, while salivary components such as viscosity and mucin have minimal impact. However, upon transition to human saliva, the presence of salivary proteins exerted a profound effect on the sensing performance. To reduce this impact, we discovered that a high NaCl concentration could significantly enhance the sensing response in saliva. This approach circumvents centrifugation and extensive dilution and facilitates cocaine detection in human saliva through a straightforward “mix-and-detect” method. This disposable aptasensor achieved a limit of detection (LOD) of 3.7 μM in 90% saliva, demonstrating immense promise for the application of electrochemical aptasensors in detecting cocaine, especially when administered via smoking.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"100 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2025-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c03423","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Electrochemical aptamer-based biosensors (E-aptasensors) are emerging platforms for point-of-care (POC) detection of complex biofluids. Human saliva particularly offers a noninvasive matrix and unprecedented convenience for detecting illicit drugs, such as cocaine. However, the sensitivity of cocaine E-aptasensors is significantly compromised in saliva. Herein, we investigated the influence of salivary components on the sensing performance of a methylene blue (MB)-labeled classic cocaine aptamer by square-wave voltammetry (SWV), and in parallel, we report the development and optimization of a disposable E-aptasensor for cocaine detection fabricated by laser ablation. Cyclic voltammetry (CV), scanning electron microscopy (SEM), and atomic force microscopy (AFM) were used to study the cleanliness and surface topography of the disposable electrode surface. To enhance the sensing performance of the disposable platform, we developed a co-immobilization strategy by introducing both the target and 6-mercapto-1-hexanol (MCH) into the aptamer immobilization solution, achieving optimal sensing performance at the aptamer-to-MCH ratio of 1:100. In a buffer solution, we revealed that the aptasensor performs best at low ionic strength, the absence of multivalent ions, and neutral pH conditions, while salivary components such as viscosity and mucin have minimal impact. However, upon transition to human saliva, the presence of salivary proteins exerted a profound effect on the sensing performance. To reduce this impact, we discovered that a high NaCl concentration could significantly enhance the sensing response in saliva. This approach circumvents centrifugation and extensive dilution and facilitates cocaine detection in human saliva through a straightforward “mix-and-detect” method. This disposable aptasensor achieved a limit of detection (LOD) of 3.7 μM in 90% saliva, demonstrating immense promise for the application of electrochemical aptasensors in detecting cocaine, especially when administered via smoking.
期刊介绍:
Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.