Comparison of the performance of myopia control in European children and adolescents with defocus incorporated multiple segments (DIMS) and highly aspherical lenslets (HAL) spectacles.

IF 2 4区 医学 Q2 PEDIATRICS
Andrea Lembo, Irene Schiavetti, Massimiliano Serafino, Roberto Caputo, Paolo Nucci
{"title":"Comparison of the performance of myopia control in European children and adolescents with defocus incorporated multiple segments (DIMS) and highly aspherical lenslets (HAL) spectacles.","authors":"Andrea Lembo, Irene Schiavetti, Massimiliano Serafino, Roberto Caputo, Paolo Nucci","doi":"10.1136/bmjpo-2024-003187","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>A performance comparison of two myopia control spectacle lens designs, defocus incorporated multiple segments (DIMS) and highly aspherical lenslets (HAL), at slowing myopia progression in a European child/adolescent population. Previous research directly comparing these designs has been limited to Chinese participants and 1-year follow-up. The prevalence of myopia in European child/adolescent has been estimated at 22.60%.</p><p><strong>Methods: </strong>Retrospective cohort study of individuals (6-17 years) with myopia progression. Participants wore DIMS (Hoya MiyoSmart) or HAL (Essilor Stellest) spectacles for a minimum of 2 years. Axial length (AL) and cycloplegic autorefraction (spherical equivalent refraction (SER)) were measured at baseline and 1 and 2 years.</p><p><strong>Results: </strong>Mean 1-year SER changes for DIMS were -0.34D (±0.46 SD) and HAL -0.30D (±0.30); 2-year changes for DIMS were -0.50D (±0.64 SD) and HAL -0.63D (±0.56). Mean 1-year AL increases for DIMS were 0.19 mm (±0.56) and HAL 0.15 mm (±0.47); 2-year increases for DIMS were 0.29 mm (±0.63) and HAL 0.32 mm (±0.72). For equivalence margins of 0.25D and 0.50D for SER at 1 and 2 years, respectively, and similarly 0.20 mm and 0.30 mm margins for AL, DIMS and HAL lenses were equivalent apart from AL at 1 year where the 0.21 mm 95% CI upper limit just exceeded 0.20 mm. At both 1 and 2 years, none of the differences in mean SERs or ALs between DIMS and HAL were clinically or statistically significant (p≥0.05 Mann-Whitney U test). Using linear mixed model analysis, the interaction between lens type and time did not significantly affect SER or AL at 1- or 2-year follow-up (p≥0.05). 38.4% of children/adolescents with DIMS had no SER progression at 2 years, compared with 21.9% with HAL (p=0.047).</p><p><strong>Conclusion: </strong>In a European population, DIMS and HAL lenses are essentially equivalent in their ability to reduce myopia progression and AL elongation over a 2-year follow-up period.</p>","PeriodicalId":9069,"journal":{"name":"BMJ Paediatrics Open","volume":"8 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Paediatrics Open","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/bmjpo-2024-003187","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: A performance comparison of two myopia control spectacle lens designs, defocus incorporated multiple segments (DIMS) and highly aspherical lenslets (HAL), at slowing myopia progression in a European child/adolescent population. Previous research directly comparing these designs has been limited to Chinese participants and 1-year follow-up. The prevalence of myopia in European child/adolescent has been estimated at 22.60%.

Methods: Retrospective cohort study of individuals (6-17 years) with myopia progression. Participants wore DIMS (Hoya MiyoSmart) or HAL (Essilor Stellest) spectacles for a minimum of 2 years. Axial length (AL) and cycloplegic autorefraction (spherical equivalent refraction (SER)) were measured at baseline and 1 and 2 years.

Results: Mean 1-year SER changes for DIMS were -0.34D (±0.46 SD) and HAL -0.30D (±0.30); 2-year changes for DIMS were -0.50D (±0.64 SD) and HAL -0.63D (±0.56). Mean 1-year AL increases for DIMS were 0.19 mm (±0.56) and HAL 0.15 mm (±0.47); 2-year increases for DIMS were 0.29 mm (±0.63) and HAL 0.32 mm (±0.72). For equivalence margins of 0.25D and 0.50D for SER at 1 and 2 years, respectively, and similarly 0.20 mm and 0.30 mm margins for AL, DIMS and HAL lenses were equivalent apart from AL at 1 year where the 0.21 mm 95% CI upper limit just exceeded 0.20 mm. At both 1 and 2 years, none of the differences in mean SERs or ALs between DIMS and HAL were clinically or statistically significant (p≥0.05 Mann-Whitney U test). Using linear mixed model analysis, the interaction between lens type and time did not significantly affect SER or AL at 1- or 2-year follow-up (p≥0.05). 38.4% of children/adolescents with DIMS had no SER progression at 2 years, compared with 21.9% with HAL (p=0.047).

Conclusion: In a European population, DIMS and HAL lenses are essentially equivalent in their ability to reduce myopia progression and AL elongation over a 2-year follow-up period.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMJ Paediatrics Open
BMJ Paediatrics Open Medicine-Pediatrics, Perinatology and Child Health
CiteScore
4.10
自引率
3.80%
发文量
124
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信