Evaluating deuterated-xylene for use as a fusion neutron spectrometer.

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION
J L Ball, E Panontin, S Mackie, R A Tinguely, P Raj
{"title":"Evaluating deuterated-xylene for use as a fusion neutron spectrometer.","authors":"J L Ball, E Panontin, S Mackie, R A Tinguely, P Raj","doi":"10.1063/5.0219490","DOIUrl":null,"url":null,"abstract":"<p><p>The spectrum of neutrons emitted by thermonuclear plasmas encodes information about the fuel ion distribution function. Measuring these fast neutron spectra with sufficient resolution allows for the measurement of plasma properties such as the ion temperature and strength and energy of fast ion populations. Liquid organic scintillators are a commonly used fast neutron detection technology because of their high detection efficiency and ability to discriminate between neutrons and gammas. However, performing detailed spectroscopy with these detectors is difficult because of the isotropic nature of neutron scattering on protons, the dominant mechanism of interaction. Deuterium-based scintillators have shown promise as a superior spectrometer technology because of the anisotropic nature of neutron scattering on deuterium, which significantly improves the condition number of the detector response matrix [Lawrence et al., Nucl. Instrum. Methods Phys. Res., Sect. A 729, 924 (2013)]. Deuterated-xylene, now available commercially, has advantages in light output and safety over benzene-based deuterated scintillators [Becchetti et al., Nucl. Instrum. Methods Phys. Res., Sect. A 820, 112 (2016)]. We present experimental spectrum unfoldings made by 2 in. right cylindrical protiated-xylene and deuterated-xylene detectors with response matrices generated with Geant4 and additional data from the literature. We compare their performance by measuring the neutron spectrum produced by an AmBe source and deuterium-tritium (DT) neutron generators. We find that the deuterated scintillator outperforms the protiated one for AmBe and DT spectra, suggesting deuterated-xylene should be considered for future fusion neutron spectrometry applications.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"95 12","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0219490","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

The spectrum of neutrons emitted by thermonuclear plasmas encodes information about the fuel ion distribution function. Measuring these fast neutron spectra with sufficient resolution allows for the measurement of plasma properties such as the ion temperature and strength and energy of fast ion populations. Liquid organic scintillators are a commonly used fast neutron detection technology because of their high detection efficiency and ability to discriminate between neutrons and gammas. However, performing detailed spectroscopy with these detectors is difficult because of the isotropic nature of neutron scattering on protons, the dominant mechanism of interaction. Deuterium-based scintillators have shown promise as a superior spectrometer technology because of the anisotropic nature of neutron scattering on deuterium, which significantly improves the condition number of the detector response matrix [Lawrence et al., Nucl. Instrum. Methods Phys. Res., Sect. A 729, 924 (2013)]. Deuterated-xylene, now available commercially, has advantages in light output and safety over benzene-based deuterated scintillators [Becchetti et al., Nucl. Instrum. Methods Phys. Res., Sect. A 820, 112 (2016)]. We present experimental spectrum unfoldings made by 2 in. right cylindrical protiated-xylene and deuterated-xylene detectors with response matrices generated with Geant4 and additional data from the literature. We compare their performance by measuring the neutron spectrum produced by an AmBe source and deuterium-tritium (DT) neutron generators. We find that the deuterated scintillator outperforms the protiated one for AmBe and DT spectra, suggesting deuterated-xylene should be considered for future fusion neutron spectrometry applications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信