Spurious radiated power signal following massive material injections in JET and the effect of neutral gas pressure on resistive bolometers.

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION
N Schoonheere, C Reux, H Meister, P Beyer, P Carvalho, I Coffey, K Lawson, P Puglia, U Sheikh
{"title":"Spurious radiated power signal following massive material injections in JET and the effect of neutral gas pressure on resistive bolometers.","authors":"N Schoonheere, C Reux, H Meister, P Beyer, P Carvalho, I Coffey, K Lawson, P Puglia, U Sheikh","doi":"10.1063/5.0224783","DOIUrl":null,"url":null,"abstract":"<p><p>Massive material injections in the JET tokamak have been observed to substantially affect resistive bolometer measurements, resulting in a spurious radiated power signal proportional to the quantity injected and reaching up to 8 MW. These bolometers are calibrated and designed to operate in near vacuum but certain scenarios requiring large gas injections can push the neutral pressure past nominal values. This study demonstrates that the bolometry measurement can be affected at neutral pressures above 0.1 Pa following injections with standard gas valves, shattered pellet injections, and particularly massive gas injections. The power measurement of resistive bolometers is based on the temperature difference between a measurement sensor exposed to radiation and a shielded reference sensor. We employ a thermal conductivity model to demonstrate that the conduction through the gas and the distinct geometries between the sensors can affect their cooling efficiency. This additional cooling pathway, coupled with the Joule heating from the applied voltage causes the equilibrium temperatures of the sensors to diverge. Being the very basis of the measure, this temperature difference induces a signal that is erroneously interpreted as radiated power. Experiments show large discrepancies in the response to neutral pressure among bolometer channels, attributed to variations in channel physical parameters. Nonetheless, the modeled total radiated power reproduces the experimental measurements within an order of magnitude, affirming the sensitivity of resistive bolometers to neutral pressure and gas species.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"95 12","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0224783","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Massive material injections in the JET tokamak have been observed to substantially affect resistive bolometer measurements, resulting in a spurious radiated power signal proportional to the quantity injected and reaching up to 8 MW. These bolometers are calibrated and designed to operate in near vacuum but certain scenarios requiring large gas injections can push the neutral pressure past nominal values. This study demonstrates that the bolometry measurement can be affected at neutral pressures above 0.1 Pa following injections with standard gas valves, shattered pellet injections, and particularly massive gas injections. The power measurement of resistive bolometers is based on the temperature difference between a measurement sensor exposed to radiation and a shielded reference sensor. We employ a thermal conductivity model to demonstrate that the conduction through the gas and the distinct geometries between the sensors can affect their cooling efficiency. This additional cooling pathway, coupled with the Joule heating from the applied voltage causes the equilibrium temperatures of the sensors to diverge. Being the very basis of the measure, this temperature difference induces a signal that is erroneously interpreted as radiated power. Experiments show large discrepancies in the response to neutral pressure among bolometer channels, attributed to variations in channel physical parameters. Nonetheless, the modeled total radiated power reproduces the experimental measurements within an order of magnitude, affirming the sensitivity of resistive bolometers to neutral pressure and gas species.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信