{"title":"Rounded Turn SLIM Design for High-Resolution Ion Mobility Mass Spectrometry Analysis of Small Molecules","authors":"Liulin Deng, Jody C. May, Joshua K. McBee, Adam Rosen, Leonard C. Rorrer, III, Ryan Clingman, Miriam Fico, John A. McLean, Daniel DeBord","doi":"10.1021/acs.analchem.4c03808","DOIUrl":null,"url":null,"abstract":"Various rounded turn designs in Structures for Lossless Ion Manipulation (SLIM) were explored via ion trajectory simulations. The optimized design was integrated into a SLIM ion mobility (IM) system coupled with a time-of-flight (TOF) mass spectrometer (MS) for further experimental investigation. The SLIM-TOF IM-MS system was assessed for IM resolution and ion transmission efficiency across a wide <i>m</i>/<i>z</i> range using various RF frequencies and buffer gas combinations. High ion transmission efficiency and high resolution ion mobility (HRIM) separation were achieved for Agilent tune mix ions through a ∼12.8 m serpentine separation path in both nitrogen and helium. In helium, ion transmission for low <i>m</i>/<i>z</i> ions was enhanced at higher RF trapping frequency, enabling the detection of ions with <i>m</i>/<i>z</i> below 50 and all 17 amino acids from a standard mixture. Lossless ion transmission was observed for glycine (<i>m</i>/<i>z</i> 76) in both passthrough and HRIM modes. HRIM resolution was benchmarked using <i>L</i>-isoleucine, <i>L</i>-leucine, and various other isobaric and isomeric metabolites with <i>m</i>/<i>z</i> values of 60–89. This work demonstrates a rounded turn SLIM design that enables HRIM measurements for small molecule analytes, with a particular focus on metabolomics, where IM offers a means to enhance the speed, robustness, and specificity of analytical workflows.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"28 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2024-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c03808","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Various rounded turn designs in Structures for Lossless Ion Manipulation (SLIM) were explored via ion trajectory simulations. The optimized design was integrated into a SLIM ion mobility (IM) system coupled with a time-of-flight (TOF) mass spectrometer (MS) for further experimental investigation. The SLIM-TOF IM-MS system was assessed for IM resolution and ion transmission efficiency across a wide m/z range using various RF frequencies and buffer gas combinations. High ion transmission efficiency and high resolution ion mobility (HRIM) separation were achieved for Agilent tune mix ions through a ∼12.8 m serpentine separation path in both nitrogen and helium. In helium, ion transmission for low m/z ions was enhanced at higher RF trapping frequency, enabling the detection of ions with m/z below 50 and all 17 amino acids from a standard mixture. Lossless ion transmission was observed for glycine (m/z 76) in both passthrough and HRIM modes. HRIM resolution was benchmarked using L-isoleucine, L-leucine, and various other isobaric and isomeric metabolites with m/z values of 60–89. This work demonstrates a rounded turn SLIM design that enables HRIM measurements for small molecule analytes, with a particular focus on metabolomics, where IM offers a means to enhance the speed, robustness, and specificity of analytical workflows.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信