A 62 Hz high-Q 4-spiral mechanical resonator fabricated of a silicon wafer.

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION
Y Yu Klochkov, V P Mitrofanov
{"title":"A 62 Hz high-Q 4-spiral mechanical resonator fabricated of a silicon wafer.","authors":"Y Yu Klochkov, V P Mitrofanov","doi":"10.1063/5.0224255","DOIUrl":null,"url":null,"abstract":"<p><p>High purity silicon is considered as the test mass material for future cryogenic gravitational-wave detectors, in particular Einstein Telescope-low frequency and LIGO Voyager [(LIGO) Laser Interferometer Gravitational-Wave Observatory]. To reduce the thermal noise of the test masses, it is necessary to study the sources of corresponding losses. Mechanical resonators with frequencies 300 Hz-6 kHz are successfully used for studying, for example, losses in optical coatings of the test mass. However, the frequency range of the interferometric gravitational-wave detectors starts at 10 Hz, and the investigation of different dissipation mechanisms for the test masses in the low-frequency region is relevant. We developed a design of a four-spiral mechanical resonator for studying dissipation and noise in the low frequency range. The resonator was fabricated of a 3-in. silicon wafer using an anisotropic wet etching technique. It consists of four spiral cantilevers on a common base, linked together with additional coupling beams for increasing the frequency difference between the resonator normal modes corresponding to the fundamental flexural off-plane mode of a single spiral cantilever. The measured Q-factor of the 62 Hz out-of-phase mode of the four-spiral silicon resonator at room temperature is limited mainly by the thermoelastic loss. At 123 K, the measured Q = (1.5 ± 0.3) × 107. The main contribution to the total loss comes from clamping and surface losses.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"95 12","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0224255","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

High purity silicon is considered as the test mass material for future cryogenic gravitational-wave detectors, in particular Einstein Telescope-low frequency and LIGO Voyager [(LIGO) Laser Interferometer Gravitational-Wave Observatory]. To reduce the thermal noise of the test masses, it is necessary to study the sources of corresponding losses. Mechanical resonators with frequencies 300 Hz-6 kHz are successfully used for studying, for example, losses in optical coatings of the test mass. However, the frequency range of the interferometric gravitational-wave detectors starts at 10 Hz, and the investigation of different dissipation mechanisms for the test masses in the low-frequency region is relevant. We developed a design of a four-spiral mechanical resonator for studying dissipation and noise in the low frequency range. The resonator was fabricated of a 3-in. silicon wafer using an anisotropic wet etching technique. It consists of four spiral cantilevers on a common base, linked together with additional coupling beams for increasing the frequency difference between the resonator normal modes corresponding to the fundamental flexural off-plane mode of a single spiral cantilever. The measured Q-factor of the 62 Hz out-of-phase mode of the four-spiral silicon resonator at room temperature is limited mainly by the thermoelastic loss. At 123 K, the measured Q = (1.5 ± 0.3) × 107. The main contribution to the total loss comes from clamping and surface losses.

在硅晶片上制作的 62 Hz 高 Q 值 4 螺旋机械谐振器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信