Quantitative neuromuscular monitoring with train-of-four ratio using sonomechanomyography (SMMG): Toward more sensitive evaluation of neuromuscular blockade.

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION
Pancheng Zhu, Zhen Song, Stanley Sau-Ching Wong, Yongping Zheng
{"title":"Quantitative neuromuscular monitoring with train-of-four ratio using sonomechanomyography (SMMG): Toward more sensitive evaluation of neuromuscular blockade.","authors":"Pancheng Zhu, Zhen Song, Stanley Sau-Ching Wong, Yongping Zheng","doi":"10.1063/5.0243459","DOIUrl":null,"url":null,"abstract":"<p><p>In the post-anesthesia care unit, there is a high occurrence of residual neuromuscular blockade, which puts patients at risk of negative consequences such as hypoxia. Assessment based on the train-of-four ratio (TOFR) has been used to avoid residual neuromuscular blockade when the TOFR is greater than 0.9, measured at the adductor pollicis muscle (APM). The most commonly used quantitative neuromuscular monitoring (QNM) modalities include acceleromyography (AMG) and electromyography (EMG). However, the poor user-friendliness of current QNM methods hinders their widespread adoption. To overcome this, we developed a new monitoring method using ultra-fast ultrasound imaging to generate a two-dimensional map of muscle transient motion, i.e., sonomechanomyography (SMMG). SMMG of the APM and AMG of the thumb were used to get the TOFR of 20 normal adults. The results showed no significant difference between the left and right hands for both AMG and SMMG TOFR, with p-values larger than 0.05. In addition, the mean accuracy of SMMG TOFR (0.6% relative error) was higher than AMG (1.4% relative error). Moreover, the Bland-Altman plot showed that all the difference values were within the limits of agreement and the mean bias was 0.02, indicating that the two methods had a very good agreement. In particular, using SMMG did not require additional calibration before testing. Overall, the results demonstrated that the method has the potential as a new QNM approach for further clinical studies to benefit patients in need. To demonstrate its clinical potential, further studies are required to evaluate this method in patients during and post-anesthesia.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"95 12","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0243459","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

In the post-anesthesia care unit, there is a high occurrence of residual neuromuscular blockade, which puts patients at risk of negative consequences such as hypoxia. Assessment based on the train-of-four ratio (TOFR) has been used to avoid residual neuromuscular blockade when the TOFR is greater than 0.9, measured at the adductor pollicis muscle (APM). The most commonly used quantitative neuromuscular monitoring (QNM) modalities include acceleromyography (AMG) and electromyography (EMG). However, the poor user-friendliness of current QNM methods hinders their widespread adoption. To overcome this, we developed a new monitoring method using ultra-fast ultrasound imaging to generate a two-dimensional map of muscle transient motion, i.e., sonomechanomyography (SMMG). SMMG of the APM and AMG of the thumb were used to get the TOFR of 20 normal adults. The results showed no significant difference between the left and right hands for both AMG and SMMG TOFR, with p-values larger than 0.05. In addition, the mean accuracy of SMMG TOFR (0.6% relative error) was higher than AMG (1.4% relative error). Moreover, the Bland-Altman plot showed that all the difference values were within the limits of agreement and the mean bias was 0.02, indicating that the two methods had a very good agreement. In particular, using SMMG did not require additional calibration before testing. Overall, the results demonstrated that the method has the potential as a new QNM approach for further clinical studies to benefit patients in need. To demonstrate its clinical potential, further studies are required to evaluate this method in patients during and post-anesthesia.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信