Effect of excitation sequence of myocardial contraction on the mechanical response of the left ventricle

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Giorgos Troulliotis , Alison Duncan , Xiao Yun Xu , Alessandro Gandaglia , Fillipo Naso , Hendrik Versteeg , Saeed Mirsadraee , Sotiris Korossis
{"title":"Effect of excitation sequence of myocardial contraction on the mechanical response of the left ventricle","authors":"Giorgos Troulliotis ,&nbsp;Alison Duncan ,&nbsp;Xiao Yun Xu ,&nbsp;Alessandro Gandaglia ,&nbsp;Fillipo Naso ,&nbsp;Hendrik Versteeg ,&nbsp;Saeed Mirsadraee ,&nbsp;Sotiris Korossis","doi":"10.1016/j.medengphy.2024.104255","DOIUrl":null,"url":null,"abstract":"<div><div>In the past two decades there has been rapid development in the field of computational cardiac models. These have included either (i) mechanical models that assumed simultaneous myocardial activation, or (ii) electromechanical models that assumed time-varying myocardial activation. The influence of these modelling assumptions of myocardial activation on clinically relevant metrics, like myocardial strain, commonly used for validation of cardiac models has yet to be systematically examined, leading to uncertainty over their influence on the predictions of these models. This study examined the effects of simultaneous (mechanical), uniform endocardial, 3-patch endocardial (simulating the fascicles of the His-Purkinje system) and 1-patch endocardial (simulating the atrioventricular node) excitation sequences on the mechanical response of a synthetic human left ventricular model. The influence of the duration of the activation and time-to-peak contraction was also investigated. The electromechanical and mechanical models produced different strain distributions in early systole. However, these differences decayed as systole progressed. Using the same activation duration (74 ms) the average peak-systolic circumferential strain difference between the models was 0.65±0.37 %. A slightly prolonged activation duration (134 ms) resulted in no substantial difference increase (0.76±0.47 %). Differences up to 3.5 % were observed for prolonged activation durations (200 ms). Endocardial excitation produced non-physiological cumulative activation time distributions compared to the other models. Septal 1-patch excitation resulted in early systolic strain response that resembled pathological left bundle branch block. Decreased time-to-peak contraction exaggerated the effects of electrophysiology. The study found that excitation sequence minimally affects strain distributions at peak systole for physiological and even slightly pathological activation durations. However, electromechanical models with (patho)physiologically informed activation sequences are important for the accurate prediction of early systolic and pathological late systolic responses.</div></div>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":"134 ","pages":"Article 104255"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350453324001565","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In the past two decades there has been rapid development in the field of computational cardiac models. These have included either (i) mechanical models that assumed simultaneous myocardial activation, or (ii) electromechanical models that assumed time-varying myocardial activation. The influence of these modelling assumptions of myocardial activation on clinically relevant metrics, like myocardial strain, commonly used for validation of cardiac models has yet to be systematically examined, leading to uncertainty over their influence on the predictions of these models. This study examined the effects of simultaneous (mechanical), uniform endocardial, 3-patch endocardial (simulating the fascicles of the His-Purkinje system) and 1-patch endocardial (simulating the atrioventricular node) excitation sequences on the mechanical response of a synthetic human left ventricular model. The influence of the duration of the activation and time-to-peak contraction was also investigated. The electromechanical and mechanical models produced different strain distributions in early systole. However, these differences decayed as systole progressed. Using the same activation duration (74 ms) the average peak-systolic circumferential strain difference between the models was 0.65±0.37 %. A slightly prolonged activation duration (134 ms) resulted in no substantial difference increase (0.76±0.47 %). Differences up to 3.5 % were observed for prolonged activation durations (200 ms). Endocardial excitation produced non-physiological cumulative activation time distributions compared to the other models. Septal 1-patch excitation resulted in early systolic strain response that resembled pathological left bundle branch block. Decreased time-to-peak contraction exaggerated the effects of electrophysiology. The study found that excitation sequence minimally affects strain distributions at peak systole for physiological and even slightly pathological activation durations. However, electromechanical models with (patho)physiologically informed activation sequences are important for the accurate prediction of early systolic and pathological late systolic responses.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Engineering & Physics
Medical Engineering & Physics 工程技术-工程:生物医学
CiteScore
4.30
自引率
4.50%
发文量
172
审稿时长
3.0 months
期刊介绍: Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信