Woohyuk Sim , Chanyoung Kim , Young-Doo Yoon , Tonghun Lee , Jihyung Yoo
{"title":"Direct motor rotor pyrometry using mid-infrared hollow waveguide","authors":"Woohyuk Sim , Chanyoung Kim , Young-Doo Yoon , Tonghun Lee , Jihyung Yoo","doi":"10.1016/j.measurement.2024.116081","DOIUrl":null,"url":null,"abstract":"<div><div>A remote pyrometry method was applied to an interior permanent magnet synchronous motor (IPMSM) for a direct measurement of its rotor component temperatures. An accurate means of permanent magnet (PM) thermometry is a critical factor in an IPMSM design and operation since excessive heat can lead to irreversible performance degradation of the motor. A hollow waveguide (HWG) mounted inside the motor housing, just above the rotor end surface, collected mid-infrared surface emissions from exposed PMs and rotor core sections during rotation. The signal was then analyzed to resolve temperatures across small rotation angles along the trajectory traced out by the HWG. The sensor was calibrated in laboratory conditions and demonstrated on an actual motor under various operating conditions. The sensor enabled direct temperature measurements to within <span><math><mrow><mo>±</mo><mn>3</mn><mspace></mspace><mo>°</mo><mi>C</mi></mrow></math></span> uncertainty near room temperature with <span><math><mrow><mo>±</mo><msup><mrow><mn>1</mn></mrow><mrow><mo>∘</mo></mrow></msup></mrow></math></span> angular resolution at 4500 RPM. The uncertainty decreased to less than <span><math><mrow><mo>±</mo><mn>1</mn><mspace></mspace><mo>°</mo><mi>C</mi></mrow></math></span> above 100 °C.</div></div>","PeriodicalId":18349,"journal":{"name":"Measurement","volume":"242 ","pages":"Article 116081"},"PeriodicalIF":5.2000,"publicationDate":"2024-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0263224124019663","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
A remote pyrometry method was applied to an interior permanent magnet synchronous motor (IPMSM) for a direct measurement of its rotor component temperatures. An accurate means of permanent magnet (PM) thermometry is a critical factor in an IPMSM design and operation since excessive heat can lead to irreversible performance degradation of the motor. A hollow waveguide (HWG) mounted inside the motor housing, just above the rotor end surface, collected mid-infrared surface emissions from exposed PMs and rotor core sections during rotation. The signal was then analyzed to resolve temperatures across small rotation angles along the trajectory traced out by the HWG. The sensor was calibrated in laboratory conditions and demonstrated on an actual motor under various operating conditions. The sensor enabled direct temperature measurements to within uncertainty near room temperature with angular resolution at 4500 RPM. The uncertainty decreased to less than above 100 °C.
期刊介绍:
Contributions are invited on novel achievements in all fields of measurement and instrumentation science and technology. Authors are encouraged to submit novel material, whose ultimate goal is an advancement in the state of the art of: measurement and metrology fundamentals, sensors, measurement instruments, measurement and estimation techniques, measurement data processing and fusion algorithms, evaluation procedures and methodologies for plants and industrial processes, performance analysis of systems, processes and algorithms, mathematical models for measurement-oriented purposes, distributed measurement systems in a connected world.