PCG-based exercise fatigue detection method using multi-scale feature fusion model.

IF 1.7 4区 医学 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
Xinxin Ma, Xinhua Su, Huanmin Ge, Yuru Chen
{"title":"PCG-based exercise fatigue detection method using multi-scale feature fusion model.","authors":"Xinxin Ma, Xinhua Su, Huanmin Ge, Yuru Chen","doi":"10.1080/10255842.2024.2406369","DOIUrl":null,"url":null,"abstract":"<p><p>Accurate detection of exercise fatigue based on physiological signals is vital for reasonable physical activity. Existing studies utilize widely Electrocardiogram (ECG) signals to achieve exercise monitoring. Nevertheless, ECG signals may be corrupted because of sweat or loose connection. As a non-invasive technique, Phonocardiogram (PCG) signals have a strong ability to reflect the Cardiovascular information, which is closely related to physical state. Therefore, a novel PCG-based detection method is proposed, where the feature fusion of deep learning features and linear features is the key technology of improving fatigue detection performance. Specifically, Short-Time Fourier Transform (STFT) is employed to convert 1D PCG signals into 2D images, and images are fed into the pre-trained convolutional neural network (VGG-16) for learning. Then, the fusion features are constructed by concatenating the VGG-16 output features and PCG linear features. Finally, the concatenated features are sent to Support Vector Machines (SVM) and Linear Discriminant Analysis (LDA) to distinguish six levels of exercise fatigue. The experimental results of two datasets show that the best performance of the proposed method achieves 91.47% and 99.00% accuracy, 91.49% and 99.09% F1-score, 90.99% and 99.07% sensitivity, which has comparable performance to an ECG-based system which is as gold standard (94.32% accuracy, 94.33% F1-score, 94.52% sensitivity).</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2024.2406369","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

Accurate detection of exercise fatigue based on physiological signals is vital for reasonable physical activity. Existing studies utilize widely Electrocardiogram (ECG) signals to achieve exercise monitoring. Nevertheless, ECG signals may be corrupted because of sweat or loose connection. As a non-invasive technique, Phonocardiogram (PCG) signals have a strong ability to reflect the Cardiovascular information, which is closely related to physical state. Therefore, a novel PCG-based detection method is proposed, where the feature fusion of deep learning features and linear features is the key technology of improving fatigue detection performance. Specifically, Short-Time Fourier Transform (STFT) is employed to convert 1D PCG signals into 2D images, and images are fed into the pre-trained convolutional neural network (VGG-16) for learning. Then, the fusion features are constructed by concatenating the VGG-16 output features and PCG linear features. Finally, the concatenated features are sent to Support Vector Machines (SVM) and Linear Discriminant Analysis (LDA) to distinguish six levels of exercise fatigue. The experimental results of two datasets show that the best performance of the proposed method achieves 91.47% and 99.00% accuracy, 91.49% and 99.09% F1-score, 90.99% and 99.07% sensitivity, which has comparable performance to an ECG-based system which is as gold standard (94.32% accuracy, 94.33% F1-score, 94.52% sensitivity).

使用多尺度特征融合模型的基于 PCG 的运动疲劳检测方法
根据生理信号准确检测运动疲劳对合理的体育锻炼至关重要。现有研究广泛利用心电图(ECG)信号来实现运动监测。然而,心电图信号可能会因出汗或连接松动而受到破坏。作为一种无创技术,心电图(PCG)信号具有很强的反映心血管信息的能力,与身体状态密切相关。因此,本文提出了一种基于 PCG 的新型检测方法,其中深度学习特征与线性特征的融合是提高疲劳检测性能的关键技术。具体来说,利用短时傅里叶变换(STFT)将一维 PCG 信号转换为二维图像,并将图像输入预训练的卷积神经网络(VGG-16)进行学习。然后,将 VGG-16 输出特性和 PCG 线性特征串联起来,构建融合特征。最后,将并集特征送入支持向量机(SVM)和线性判别分析(LDA),以区分运动疲劳的六个等级。两个数据集的实验结果表明,所提方法的最佳性能为准确率 91.47% 和 99.00%,F1 分数 91.49% 和 99.09%,灵敏度 90.99% 和 99.07%,与作为黄金标准的基于心电图的系统(准确率 94.32%,F1 分数 94.33%,灵敏度 94.52%)性能相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
6.20%
发文量
179
审稿时长
4-8 weeks
期刊介绍: The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信