A Digital Twin-Based Large-Area Robot Skin System for Safer Human-Centered Healthcare Robots Toward Healthcare 4.0

IF 3.4 Q2 ENGINEERING, BIOMEDICAL
Geng Yang;Zhiqiu Ye;Haiteng Wu;Chen Li;Ruohan Wang;Depeng Kong;Zeyang Hou;Huafen Wang;Xiaoyan Huang;Zhibo Pang;Na Dong;Gaoyang Pang
{"title":"A Digital Twin-Based Large-Area Robot Skin System for Safer Human-Centered Healthcare Robots Toward Healthcare 4.0","authors":"Geng Yang;Zhiqiu Ye;Haiteng Wu;Chen Li;Ruohan Wang;Depeng Kong;Zeyang Hou;Huafen Wang;Xiaoyan Huang;Zhibo Pang;Na Dong;Gaoyang Pang","doi":"10.1109/TMRB.2024.3421635","DOIUrl":null,"url":null,"abstract":"The fourth revolution of healthcare technologies, i.e., Healthcare 4.0, is putting robotics into human-dominated environments. In such a context, one of the main challenges is to develop human-centered robotics technologies that enable safe and reliable human-robot interaction toward human-robot symbiosis. Herein, robot skin is developed to endow healthcare robots with on-body proximity perception so as to fulfill the promise of safe and reliable robotic systems alongside humans. The sensing performance of the robot skin is evaluated by extensive experiments, providing important guidance on its effective implementation into a specific robot platform. Results show that the developed robot skin has a detection range of 0–50 mm, a maximum sensitivity of 0.7 pF/mm, a minimum resolution of 0.05 mm, a repeatability error of 6.6%, a hysteresis error of 7.1%, and bending durability of 2000 cycles. The robot skin is further customized and scaled up to form a large-area sensing system on the exterior of robot arms to support functional safety, which is experimentally validated by approaching distance monitoring and reactive collision avoidance. During the validation, the sensing feedback of the robot skin and the motion of the host robot are visualized remotely in the robot digital twin in a real-time manner via a cloud server. The cloud-based monitoring interface bridges the gap between local healthcare robots and remote professionals, illustrating promising applications where professionals monitor the robot state and intervene in challenging situations to provide instant support for emergent safety issues in human-robot interaction.","PeriodicalId":73318,"journal":{"name":"IEEE transactions on medical robotics and bionics","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical robotics and bionics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10579909/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The fourth revolution of healthcare technologies, i.e., Healthcare 4.0, is putting robotics into human-dominated environments. In such a context, one of the main challenges is to develop human-centered robotics technologies that enable safe and reliable human-robot interaction toward human-robot symbiosis. Herein, robot skin is developed to endow healthcare robots with on-body proximity perception so as to fulfill the promise of safe and reliable robotic systems alongside humans. The sensing performance of the robot skin is evaluated by extensive experiments, providing important guidance on its effective implementation into a specific robot platform. Results show that the developed robot skin has a detection range of 0–50 mm, a maximum sensitivity of 0.7 pF/mm, a minimum resolution of 0.05 mm, a repeatability error of 6.6%, a hysteresis error of 7.1%, and bending durability of 2000 cycles. The robot skin is further customized and scaled up to form a large-area sensing system on the exterior of robot arms to support functional safety, which is experimentally validated by approaching distance monitoring and reactive collision avoidance. During the validation, the sensing feedback of the robot skin and the motion of the host robot are visualized remotely in the robot digital twin in a real-time manner via a cloud server. The cloud-based monitoring interface bridges the gap between local healthcare robots and remote professionals, illustrating promising applications where professionals monitor the robot state and intervene in challenging situations to provide instant support for emergent safety issues in human-robot interaction.
基于数字孪生的大面积机器人皮肤系统,实现更安全的以人为本的医疗保健机器人,迈向医疗保健 4.0
医疗保健技术的第四次革命,即医疗保健 4.0,正在将机器人技术引入人类主导的环境。在此背景下,主要挑战之一是开发以人为本的机器人技术,实现安全可靠的人机交互,实现人机共生。在此,我们开发了机器人皮肤,赋予医疗保健机器人身体接近感知能力,以实现安全可靠的机器人系统与人类共存的承诺。通过大量实验对机器人皮肤的感知性能进行了评估,为其在特定机器人平台上的有效实施提供了重要指导。结果表明,所开发的机器人皮肤检测范围为 0-50 毫米,最大灵敏度为 0.7 pF/mm,最小分辨率为 0.05 毫米,重复性误差为 6.6%,滞后误差为 7.1%,弯曲耐久性为 2000 次循环。该机器人皮肤经过进一步定制和放大,在机器人手臂外部形成了一个大面积传感系统,以支持功能安全,并通过接近距离监测和反应式防撞进行了实验验证。在验证过程中,机器人皮肤的传感反馈和主机机器人的运动通过云服务器在机器人数字孪生中实时远程可视化。基于云的监控界面在本地医疗保健机器人和远程专业人员之间架起了桥梁,展示了专业人员监控机器人状态并在具有挑战性的情况下进行干预,为人机交互中出现的安全问题提供即时支持的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信