{"title":"Do measures of gain asymmetry and catch-up saccades improve video head impulse test agreement with caloric results?","authors":"I. Zay Melville , Kyla Yamsuan , Helen Wu , Peter R. Thorne , Kei Kobayashi , Rachael L. Taylor","doi":"10.1016/j.cnp.2024.07.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>To investigate the relative sensitivity and agreement of caloric testing and video head impulse test (vHIT) across four groups of vestibular disorders.</p></div><div><h3>Methods</h3><p>Caloric and vHIT results of 118 patients with either Ménière’s disease, vestibular neuritis/labyrinthitis, vestibular migraine, or vestibular schwannoma were retrospectively analyzed. vHIT gain, gain asymmetry, and catch-up-saccades (≥100°/sec) were compared with reference limits of 91 controls.</p></div><div><h3>Results</h3><p>Abnormal caloric results and vHIT gain were recorded in 57.6 % and 33.1 % of patients, respectively. Consideration of all three measures increased vHIT sensitivity to 43.2 %, and concordance with caloric results improved from 66.1 % to 70.3 %. A significant interaction effect confirmed the relationship between tests depended on the diagnosis (p = 0.013). Vestibular migraine and vestibular neuritis/labyrinthitis produced similar results on both tests, usually normal and abnormal respectively. Vestibular schwannoma produced more caloric abnormalities than vHIT gain but not compared with catch-up-saccades and gain asymmetry; Ménière’s disease produced more caloric abnormalities than all vHIT measures. When vHIT was normal (all measures), a 37 % canal paresis was 90 % specific for Ménière’s disease.</p></div><div><h3>Conclusions</h3><p>Rates of vHIT catch-up-saccades and gain asymmetry can improve sensitivity and concordance with caloric testing, but this is disease-dependent.</p></div><div><h3>Significance</h3><p>vHIT outcome measures are complementary to the caloric test and each other.</p></div>","PeriodicalId":45697,"journal":{"name":"Clinical Neurophysiology Practice","volume":"9 ","pages":"Pages 217-226"},"PeriodicalIF":2.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2467981X24000209/pdfft?md5=7818b0a50eef5b4bed91e0a41abd8b17&pid=1-s2.0-S2467981X24000209-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neurophysiology Practice","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2467981X24000209","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
To investigate the relative sensitivity and agreement of caloric testing and video head impulse test (vHIT) across four groups of vestibular disorders.
Methods
Caloric and vHIT results of 118 patients with either Ménière’s disease, vestibular neuritis/labyrinthitis, vestibular migraine, or vestibular schwannoma were retrospectively analyzed. vHIT gain, gain asymmetry, and catch-up-saccades (≥100°/sec) were compared with reference limits of 91 controls.
Results
Abnormal caloric results and vHIT gain were recorded in 57.6 % and 33.1 % of patients, respectively. Consideration of all three measures increased vHIT sensitivity to 43.2 %, and concordance with caloric results improved from 66.1 % to 70.3 %. A significant interaction effect confirmed the relationship between tests depended on the diagnosis (p = 0.013). Vestibular migraine and vestibular neuritis/labyrinthitis produced similar results on both tests, usually normal and abnormal respectively. Vestibular schwannoma produced more caloric abnormalities than vHIT gain but not compared with catch-up-saccades and gain asymmetry; Ménière’s disease produced more caloric abnormalities than all vHIT measures. When vHIT was normal (all measures), a 37 % canal paresis was 90 % specific for Ménière’s disease.
Conclusions
Rates of vHIT catch-up-saccades and gain asymmetry can improve sensitivity and concordance with caloric testing, but this is disease-dependent.
Significance
vHIT outcome measures are complementary to the caloric test and each other.
期刊介绍:
Clinical Neurophysiology Practice (CNP) is a new Open Access journal that focuses on clinical practice issues in clinical neurophysiology including relevant new research, case reports or clinical series, normal values and didactic reviews. It is an official journal of the International Federation of Clinical Neurophysiology and complements Clinical Neurophysiology which focuses on innovative research in the specialty. It has a role in supporting established clinical practice, and an educational role for trainees, technicians and practitioners.