{"title":"Performance parametric formulation of carbon fiber-reinforced composite locking bone implant plates based on finite-element analysis.","authors":"Wares Chancharoen, Jirapong Pansai, Teeravut Boonchuay, Somchart Saeya, Raj Das, Thanapon Chobpenthai, Sontipee Aimmanee","doi":"10.1080/10255842.2024.2358362","DOIUrl":null,"url":null,"abstract":"<p><p>The treatment of Giant Cell Tumor <b>(</b>GCT<b>)</b> in the distal radius poses challenges due to the intricate anatomical features of the bone. It often necessitates the use of long implant plates or the interconnection of multiple short plates after tumor excision. However, the deployment of metal plates may increase the risk of screw loosening and various complications. To address these challenges, this study proposes the adoption of carbon fiber-reinforced PEEK (CFRP) as the base material. As a unique strategy, performance parameters (PP) were developed to compare CFRP implant plates with a Ti-6Al-4V plate using the Finite-element Method. The focus was on four elements: the screw axial force, bone growth, callus formation, and bone resorption. The investigation into the screw axial force involved analyzing the internal force of the screw. The remaining parameters were evaluated using the stress, strain, or elastic energy induced in the bones. The findings showed that the second screw endured the largest screw axial force, measuring 10.16 N under a 90-degree 10-N loading at the translocated bone. The model without a callus exerted a significantly greater force on the screw than the model with a callus, leading to screw loosening in the early stage of treatment. The maximum PP, reached 1.62, was achieved with an angle-ply <b>[</b>45<sub>6</sub><b>/-</b>45<sub>6</sub><b>]</b> laminate, featuring a weighting fraction of 0.7 for bone growth and 0.1 for the other parameters. This study provides a generalized methodology for assessing the performances of CFRP implants and offers guidelines for future development in composite implant plate technology.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":" ","pages":"2083-2099"},"PeriodicalIF":1.6000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2024.2358362","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/29 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0
Abstract
The treatment of Giant Cell Tumor (GCT) in the distal radius poses challenges due to the intricate anatomical features of the bone. It often necessitates the use of long implant plates or the interconnection of multiple short plates after tumor excision. However, the deployment of metal plates may increase the risk of screw loosening and various complications. To address these challenges, this study proposes the adoption of carbon fiber-reinforced PEEK (CFRP) as the base material. As a unique strategy, performance parameters (PP) were developed to compare CFRP implant plates with a Ti-6Al-4V plate using the Finite-element Method. The focus was on four elements: the screw axial force, bone growth, callus formation, and bone resorption. The investigation into the screw axial force involved analyzing the internal force of the screw. The remaining parameters were evaluated using the stress, strain, or elastic energy induced in the bones. The findings showed that the second screw endured the largest screw axial force, measuring 10.16 N under a 90-degree 10-N loading at the translocated bone. The model without a callus exerted a significantly greater force on the screw than the model with a callus, leading to screw loosening in the early stage of treatment. The maximum PP, reached 1.62, was achieved with an angle-ply [456/-456] laminate, featuring a weighting fraction of 0.7 for bone growth and 0.1 for the other parameters. This study provides a generalized methodology for assessing the performances of CFRP implants and offers guidelines for future development in composite implant plate technology.
期刊介绍:
The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.