Neonatal Resuscitation Practices in Portuguese Delivery Rooms: A Cross-Sectional Study.

IF 0.8 4区 医学 Q3 MEDICINE, GENERAL & INTERNAL
Natacha Alves, Gustavo Rocha, Filipa Flor-de-Lima, Marta Rosário, Susana Pissarra, Mário Mateus, Inês Azevedo, Henrique Soares
{"title":"Neonatal Resuscitation Practices in Portuguese Delivery Rooms: A Cross-Sectional Study.","authors":"Natacha Alves, Gustavo Rocha, Filipa Flor-de-Lima, Marta Rosário, Susana Pissarra, Mário Mateus, Inês Azevedo, Henrique Soares","doi":"10.20344/amp.20009","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Data from previous studies have demonstrated inconsistency between current evidence and delivery room resuscitation practices in developed countries. The primary aim of this study was to assess the quality of newborn healthcare and resuscitation practices in Portuguese delivery rooms, comparing current practices with the 2021 European Resuscitation Council guidelines. The secondary aim was to compare the consistency of practices between tertiary and non-tertiary centers across Portugal.</p><p><strong>Methods: </strong>An 87-question survey concerning neonatal care was sent to all physicians registered with the Portuguese Neonatal Society via email. In order to compare practices between centers, participants were divided into two groups: Group A (level III and level IIb centers) and Group B (level IIa and I centers). A descriptive analysis of variables was performed in order to compare the two groups.</p><p><strong>Results: </strong>In total, 130 physicians responded to the survey. Group A included 91 (70%) and Group B 39 (30%) respondents. More than 80% of participants reported the presence of a healthcare professional with basic newborn resuscitation training in all deliveries, essential equipment in the delivery room, such as a resuscitator with a light and heat source, a pulse oximeter, and an O2 blender, and performing delayed cord clamping for all neonates born without complications. Less than 60% reported performing team briefing before deliveries, the presence of electrocardiogram sensors, end-tidal CO2 detector, and continuous positive airway pressure in the delivery room, and monitoring the neonate's temperature. Major differences between groups were found regarding staff attending deliveries, education, equipment, thermal control, umbilical cord management, vital signs monitoring, prophylactic surfactant administration, and the neonate's transportation out of the delivery room.</p><p><strong>Conclusion: </strong>Overall, adherence to neonatal resuscitation international guidelines was high among Portuguese physicians. However, differences between guidelines and current practices, as well as between centers with different levels of care, were identified. Areas for improvement include team briefing, ethics, education, available equipment in delivery rooms, temperature control, and airway management. The authors emphasize the importance of continuous education to ensure compliance with the most recent guidelines and ultimately improve neonatal health outcomes.</p>","PeriodicalId":7059,"journal":{"name":"Acta medica portuguesa","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta medica portuguesa","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.20344/amp.20009","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Data from previous studies have demonstrated inconsistency between current evidence and delivery room resuscitation practices in developed countries. The primary aim of this study was to assess the quality of newborn healthcare and resuscitation practices in Portuguese delivery rooms, comparing current practices with the 2021 European Resuscitation Council guidelines. The secondary aim was to compare the consistency of practices between tertiary and non-tertiary centers across Portugal.

Methods: An 87-question survey concerning neonatal care was sent to all physicians registered with the Portuguese Neonatal Society via email. In order to compare practices between centers, participants were divided into two groups: Group A (level III and level IIb centers) and Group B (level IIa and I centers). A descriptive analysis of variables was performed in order to compare the two groups.

Results: In total, 130 physicians responded to the survey. Group A included 91 (70%) and Group B 39 (30%) respondents. More than 80% of participants reported the presence of a healthcare professional with basic newborn resuscitation training in all deliveries, essential equipment in the delivery room, such as a resuscitator with a light and heat source, a pulse oximeter, and an O2 blender, and performing delayed cord clamping for all neonates born without complications. Less than 60% reported performing team briefing before deliveries, the presence of electrocardiogram sensors, end-tidal CO2 detector, and continuous positive airway pressure in the delivery room, and monitoring the neonate's temperature. Major differences between groups were found regarding staff attending deliveries, education, equipment, thermal control, umbilical cord management, vital signs monitoring, prophylactic surfactant administration, and the neonate's transportation out of the delivery room.

Conclusion: Overall, adherence to neonatal resuscitation international guidelines was high among Portuguese physicians. However, differences between guidelines and current practices, as well as between centers with different levels of care, were identified. Areas for improvement include team briefing, ethics, education, available equipment in delivery rooms, temperature control, and airway management. The authors emphasize the importance of continuous education to ensure compliance with the most recent guidelines and ultimately improve neonatal health outcomes.

葡萄牙产房的新生儿复苏实践:一项横断面研究。
导言:以往的研究数据表明,发达国家目前的证据与产房复苏实践不一致。本研究的主要目的是评估葡萄牙产房的新生儿医疗质量和复苏实践,并将当前实践与 2021 年欧洲复苏委员会指南进行比较。次要目的是比较葡萄牙各地三级和非三级中心的做法是否一致:通过电子邮件向所有在葡萄牙新生儿协会注册的医生发送了一份包含 87 个问题的新生儿护理调查问卷。为了比较不同中心的做法,参与者被分为两组:A组(三级和二级b中心)和B组(二级a和一级中心)。为了对两组进行比较,我们对变量进行了描述性分析:共有 130 名医生回复了调查。A组包括91名(70%)受访者,B组包括39名(30%)受访者。超过 80% 的受访者表示在所有分娩过程中都有一名接受过基本新生儿复苏培训的医护人员在场,产房内有必要的设备,如带光源和热源的复苏器、脉搏血氧计和氧气混合器,并对所有无并发症的新生儿进行延迟脐带夹闭。只有不到 60% 的人表示在分娩前进行了团队简报,在产房内安装了心电图传感器、潮气末二氧化碳检测仪和持续气道正压,并监测了新生儿的体温。在接生人员、教育、设备、热控制、脐带管理、生命体征监测、预防性表面活性物质的使用以及将新生儿送出产室等方面,各组之间存在较大差异:总体而言,葡萄牙医生对新生儿复苏国际指南的遵守程度较高。然而,我们也发现了指南与当前实践之间的差异,以及不同护理水平的中心之间的差异。需要改进的方面包括团队简报、伦理、教育、产房可用设备、温度控制和气道管理。作者强调了持续教育的重要性,以确保遵守最新的指南,并最终改善新生儿的健康状况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta medica portuguesa
Acta medica portuguesa MEDICINE, GENERAL & INTERNAL-
CiteScore
1.90
自引率
16.70%
发文量
256
审稿时长
6-12 weeks
期刊介绍: The aim of Acta Médica Portuguesa is to publish original research and review articles in biomedical areas of the highest standard, covering several domains of medical knowledge, with the purpose to help doctors improve medical care. In order to accomplish these aims, Acta Médica Portuguesa publishes original articles, review articles, case reports and editorials, among others, with a focus on clinical, scientific, social, political and economic factors affecting health. Acta Médica Portuguesa will be happy to consider manuscripts for publication from authors anywhere in the world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信