{"title":"Accuracy of dental implants positioning in computer-assisted surgeries: In vitro study","authors":"","doi":"10.1016/j.jormas.2024.101828","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><div><span>The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using </span>computed tomography.</div></div><div><h3>Study design</h3><div>This prospective in-vitro study used 30 polyurethane<span><span> pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the </span>dental implants as a control group, considered as the gold standard for postoperative comparison.</span></div></div><div><h3>Results</h3><div>The difference between these methods is close to zero and not statistically significant (<em>p</em><span> > 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396.</span></div></div><div><h3>Conclusion</h3><div>The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method.</div></div>","PeriodicalId":55993,"journal":{"name":"Journal of Stomatology Oral and Maxillofacial Surgery","volume":"125 5","pages":"Article 101828"},"PeriodicalIF":1.8000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Stomatology Oral and Maxillofacial Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468785524000648","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using computed tomography.
Study design
This prospective in-vitro study used 30 polyurethane pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the dental implants as a control group, considered as the gold standard for postoperative comparison.
Results
The difference between these methods is close to zero and not statistically significant (p > 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396.
Conclusion
The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method.