Variations Among Heart Rate Varibility of Pulse Waves Simulataneously Measured at Different Sites

J. Hayano, Kento Yamamoto, Hiroki Ogasawara, E. Yuda, Y. Yoshida
{"title":"Variations Among Heart Rate Varibility of Pulse Waves Simulataneously Measured at Different Sites","authors":"J. Hayano, Kento Yamamoto, Hiroki Ogasawara, E. Yuda, Y. Yoshida","doi":"10.1109/IMFEDK.2018.8581958","DOIUrl":null,"url":null,"abstract":"Although pulse wave (PW) is widely used for assessing heart rate variability (HRV) with wearable devices, the variations intrinsically existing in HRV assessment by this method are unknown. This study examined variations among HRV indices obtained from PWs simultaneously measured at four different sites (right and left wrists and forearms) and compared them with those assessed from R-R intervals of electrocardiogram (ECG). While mean interbeat intervals showed good consistency with small inter-site variation (coefficient of variation [CV], 0.8% and 0.5% for supine and sitting positions) and modest deviation from that assessed from ECG (coefficient of deviation [CD], 3.1 % and 2.0%), low and high frequency components of HRV showed non-negligible inconsistency with large inter-site variations (CV, 4.0% and 3.8% for supine and 3.6% and 4.7% for sitting) and deviations from those with ECG (CD, 29.3% and 51.3% for supine and 18.5% and 40.2% for sitting).","PeriodicalId":434417,"journal":{"name":"2018 IEEE International Meeting for Future of Electron Devices, Kansai (IMFEDK)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Meeting for Future of Electron Devices, Kansai (IMFEDK)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMFEDK.2018.8581958","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Although pulse wave (PW) is widely used for assessing heart rate variability (HRV) with wearable devices, the variations intrinsically existing in HRV assessment by this method are unknown. This study examined variations among HRV indices obtained from PWs simultaneously measured at four different sites (right and left wrists and forearms) and compared them with those assessed from R-R intervals of electrocardiogram (ECG). While mean interbeat intervals showed good consistency with small inter-site variation (coefficient of variation [CV], 0.8% and 0.5% for supine and sitting positions) and modest deviation from that assessed from ECG (coefficient of deviation [CD], 3.1 % and 2.0%), low and high frequency components of HRV showed non-negligible inconsistency with large inter-site variations (CV, 4.0% and 3.8% for supine and 3.6% and 4.7% for sitting) and deviations from those with ECG (CD, 29.3% and 51.3% for supine and 18.5% and 40.2% for sitting).
不同部位同时测量脉搏波心率变异性的变化
虽然脉搏波(PW)被广泛用于可穿戴设备的心率变异性(HRV)评估,但这种方法在HRV评估中固有的变化是未知的。本研究检查了在四个不同部位(右、左手腕和前臂)同时测量的PWs获得的HRV指数之间的差异,并将其与心电图(ECG) R-R间隔评估的结果进行了比较。虽然平均搏动间隔与较小的位点间变异(变异系数[CV],仰卧位和坐姿分别为0.8%和0.5%)以及与ECG评估的适度偏差(偏差系数[CD], 3.1%和2.0%)表现出良好的一致性,但HRV的低频和高频成分与较大的位点间变异(CV,仰卧位为4.0%和3.8%,坐位为3.6%和4.7%)以及与ECG (CD,仰卧位分别为29.3%和51.3%,坐位分别为18.5%和40.2%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信