Development of EHD ion-drag micropump for microscale electronics cooling

C. Lee, A. Robinson, C. Ching
{"title":"Development of EHD ion-drag micropump for microscale electronics cooling","authors":"C. Lee, A. Robinson, C. Ching","doi":"10.1109/THERMINIC.2007.4451745","DOIUrl":null,"url":null,"abstract":"In this investigation, the numerical simulation of electrohydrodynamic (EHD) ion-drag micropumps with micropillar electrode geometries have been performed. The effect of micropillar height and electrode spacing on the performance of the micropumps was investigated. The performance of the EHD micropump improved with increased applied voltage and decreased electrode spacing. The optimum micropillar height for the micropump with electrode spacing of 40 mum and channel height of 100 mum at 200 V was 40 mum, where a maximum mass flow rate of 0.18g/min was predicted. Compared to that of planar electrodes, the 3D micropillar electrode geometry enhanced the overall performance of the EHD micropumps.","PeriodicalId":264943,"journal":{"name":"2007 13th International Workshop on Thermal Investigation of ICs and Systems (THERMINIC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 13th International Workshop on Thermal Investigation of ICs and Systems (THERMINIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/THERMINIC.2007.4451745","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

In this investigation, the numerical simulation of electrohydrodynamic (EHD) ion-drag micropumps with micropillar electrode geometries have been performed. The effect of micropillar height and electrode spacing on the performance of the micropumps was investigated. The performance of the EHD micropump improved with increased applied voltage and decreased electrode spacing. The optimum micropillar height for the micropump with electrode spacing of 40 mum and channel height of 100 mum at 200 V was 40 mum, where a maximum mass flow rate of 0.18g/min was predicted. Compared to that of planar electrodes, the 3D micropillar electrode geometry enhanced the overall performance of the EHD micropumps.
用于微电子冷却的EHD离子拖动微泵的研制
在本研究中,对具有微柱电极几何形状的电流体动力学(EHD)离子拖动微泵进行了数值模拟。研究了微柱高度和电极间距对微泵性能的影响。EHD微泵的性能随着外加电压的增加和电极间距的减小而改善。当电极间距为40 μ m,通道高度为100 μ m时,在200 V电压下微泵的最佳微柱高度为40 μ m,最大质量流量为0.18g/min。与平面电极相比,三维微柱电极几何结构提高了EHD微泵的整体性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信