{"title":"Sample Preparation on Backside Mechanical Decapsulation Methodology for Effective Failure Analysis on Non-Exposed Die Pad Package","authors":"Ong Pei Hoon, N. Kay, Gwee Hoon Yen","doi":"10.1109/IPFA.2018.8452566","DOIUrl":null,"url":null,"abstract":"Exposing the die backside is an important step in backside analysis. One of the most common techniques used is chemical preparation. However, the drawback of this technique for small non-exposed die pad package is that the copper lead will over etch by the 65% Acid Nitric Fuming if the device is not proper sealed with 3M High Temperature Tape. As a result, not able to proceed to further electrical measurements In view of this the mechanical decapsulation is an alternative solution to the existing procedure on the non-exposed die pad backside preparation. The end result of this technique is that the copper lead is intact and electrical measurement can be performed to improve the effectiveness and accuracy of physical failure analysis.","PeriodicalId":382811,"journal":{"name":"2018 IEEE International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPFA.2018.8452566","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Exposing the die backside is an important step in backside analysis. One of the most common techniques used is chemical preparation. However, the drawback of this technique for small non-exposed die pad package is that the copper lead will over etch by the 65% Acid Nitric Fuming if the device is not proper sealed with 3M High Temperature Tape. As a result, not able to proceed to further electrical measurements In view of this the mechanical decapsulation is an alternative solution to the existing procedure on the non-exposed die pad backside preparation. The end result of this technique is that the copper lead is intact and electrical measurement can be performed to improve the effectiveness and accuracy of physical failure analysis.
非暴露模垫封装背面机械解封方法的样品制备及有效失效分析
显露模具背面是背面分析的重要步骤。最常用的技术之一是化学制备。然而,对于小型非暴露的模垫封装,这种技术的缺点是,如果设备没有用3M高温胶带正确密封,则铜铅将被65%的硝酸发烟过度蚀刻。因此,无法进行进一步的电气测量。鉴于此,机械脱囊是现有的非暴露模垫背面制备程序的替代解决方案。该技术的最终结果是铜铅是完整的,并且可以进行电气测量,以提高物理失效分析的有效性和准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信