Performance of New Copper Based Metallization Systems in an 85°C 80-Percent RH Cl 2 Contaminated Environment

N. Sbar, L. Feinstein
{"title":"Performance of New Copper Based Metallization Systems in an 85°C 80-Percent RH Cl 2 Contaminated Environment","authors":"N. Sbar, L. Feinstein","doi":"10.1109/TPHP.1977.1135194","DOIUrl":null,"url":null,"abstract":"The performance of TPCNA (Ti-Pd-Cu-Ni-Au) and TCN+A (Ti-CuoNi+Au in selected areas only) meta!lizations in 85°C, 80-percent RH, with 0.5 to 1.8 ppm Cl 2 was compared with that of the standard TPA (Ti-Pd-Au) metallization. Encapsulated (RTV silicone rubber) and unencapsulated triple track conductor test specimens were used. Electrolytic corrosion was studied by biasing the specimens in the high humidity corrosive environment and measuring in situ leakage currents as a function of time. For the unencapsulated specimens, leakage currents increased and all samples failed by 600 h. The failure rates for TPCNA and TCN+A samples due to the formation of Cu and Ni dendrites between oppositely biased conductors were the same as for TPA which had Au and Pd dentrites. None of the encapsulated samples showed dendrite growth after ~ 1000 h. Unencapsulated TPCNA and TCN+A were less resistant to galvanic corrosion in the moist Cl 2 contaminated environment than were the TPA specimens. TCN+A failed first by Ti-Cu delamination and later by delamination of the Au due to corrosive oxidation of the underlying Ni. This latter failure mode was predominant for TPCNA. TPA conductors eventually failed at Ti-Pd interfaces. At 85°C, 80-percent RH, 1.6 ppm C!2, unencapsulated TCN+A degraded at the Ti-Cu interface ~10 times faster than unencapsulated TPA at the Ti-Pd interface. The corrosion product found on unencapsulated TPCNA and TCN+A and on Cu-NiAu external leads was identified as Cu, NiCl 2 . 3 [Cu, Ni(OH) 2 ]. The encapsulant was extremely effective in retarding galvanic corrosion. For encapsulated TCN+A and TPCNA, eventual bond failures were the result of penetration of the corrosive environment under the edges of the encapsulant. For TCN+A, encapsulation retarded the time to failure by a factor of >10. The relative resistance to galvanic corrosion in moist Cl 2 may be ranked TPA > TPCNA > TCN+A.","PeriodicalId":387212,"journal":{"name":"IEEE Transactions on Parts, Hybrids, and Packaging","volume":"304 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1977-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Parts, Hybrids, and Packaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TPHP.1977.1135194","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

The performance of TPCNA (Ti-Pd-Cu-Ni-Au) and TCN+A (Ti-CuoNi+Au in selected areas only) meta!lizations in 85°C, 80-percent RH, with 0.5 to 1.8 ppm Cl 2 was compared with that of the standard TPA (Ti-Pd-Au) metallization. Encapsulated (RTV silicone rubber) and unencapsulated triple track conductor test specimens were used. Electrolytic corrosion was studied by biasing the specimens in the high humidity corrosive environment and measuring in situ leakage currents as a function of time. For the unencapsulated specimens, leakage currents increased and all samples failed by 600 h. The failure rates for TPCNA and TCN+A samples due to the formation of Cu and Ni dendrites between oppositely biased conductors were the same as for TPA which had Au and Pd dentrites. None of the encapsulated samples showed dendrite growth after ~ 1000 h. Unencapsulated TPCNA and TCN+A were less resistant to galvanic corrosion in the moist Cl 2 contaminated environment than were the TPA specimens. TCN+A failed first by Ti-Cu delamination and later by delamination of the Au due to corrosive oxidation of the underlying Ni. This latter failure mode was predominant for TPCNA. TPA conductors eventually failed at Ti-Pd interfaces. At 85°C, 80-percent RH, 1.6 ppm C!2, unencapsulated TCN+A degraded at the Ti-Cu interface ~10 times faster than unencapsulated TPA at the Ti-Pd interface. The corrosion product found on unencapsulated TPCNA and TCN+A and on Cu-NiAu external leads was identified as Cu, NiCl 2 . 3 [Cu, Ni(OH) 2 ]. The encapsulant was extremely effective in retarding galvanic corrosion. For encapsulated TCN+A and TPCNA, eventual bond failures were the result of penetration of the corrosive environment under the edges of the encapsulant. For TCN+A, encapsulation retarded the time to failure by a factor of >10. The relative resistance to galvanic corrosion in moist Cl 2 may be ranked TPA > TPCNA > TCN+A.
新型铜基金属化系统在85°C 80% RH Cl 2污染环境下的性能
TPCNA (Ti-Pd-Cu-Ni-Au)和TCN+A (Ti-CuoNi+Au仅在选定区域)的性能。与标准TPA (Ti-Pd-Au)金属化工艺相比,在85°C, 80% RH, 0.5 ~ 1.8 ppm Cl 2条件下进行了比较。采用封装(RTV硅橡胶)和未封装的三轨导体试件。通过在高湿腐蚀环境中对试样进行偏置,测量泄漏电流随时间的变化规律,对电解腐蚀进行了研究。对于未封装的样品,泄漏电流增加,所有样品在600 h后失效。TPCNA和TCN+A样品由于相反偏置导体之间形成Cu和Ni枝晶而故障率与具有Au和Pd枝晶的TPA样品相同。在~ 1000 h后,未包封的TPCNA和TCN+A在潮湿的Cl 2污染环境中对电偶腐蚀的抵抗能力不如TPA样品。TCN+A首先由于Ti-Cu分层而失效,随后由于下伏Ni的腐蚀氧化而导致Au分层。后一种失效模式在TPCNA中占主导地位。TPA导体最终在Ti-Pd界面失效。在85°C, 80% RH, 1.6 ppm C!2、未封装TCN+A在Ti-Cu界面的降解速度比未封装TPA在Ti-Pd界面的降解速度快10倍。在未封装的TPCNA和TCN+A以及Cu- niau外部引线上发现的腐蚀产物为Cu, NiCl 2。3 [Cu, Ni(OH) 2]。这种密封剂在减缓电偶腐蚀方面非常有效。对于封装的TCN+A和TPCNA,最终的粘结失效是封装剂边缘下腐蚀环境渗透的结果。对于TCN+A,封装将故障时间延迟了10倍以上。相对耐湿Cl 2电偶腐蚀的等级为TPA > TPCNA > TCN+A。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信