Safety Concerns on Ground Fault Application Transfer Phenomenon in HV Installations

S. Mangione, L. Mineo
{"title":"Safety Concerns on Ground Fault Application Transfer Phenomenon in HV Installations","authors":"S. Mangione, L. Mineo","doi":"10.1109/PSES.2007.4378477","DOIUrl":null,"url":null,"abstract":"When a fault to ground occurs in HV/MV substations supplied by a combined overhead-cable line, most of the fault current can be transferred and injected into the soil several kilometers far away from the fault location. This phenomenon is called \"fault application transfer\" and mostly concerns transition stations, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, usually accessible to the general public, the local ground electrode could be inadequate to maintain ground potential rise within safety limits. Hence, dangerous touch and step voltages may appear at exposed locations. In the paper results of various computer simulations are presented, pointing out the main factors affecting the phenomenon and associated hazards.","PeriodicalId":264110,"journal":{"name":"2007 IEEE Symposium on Product Compliance Engineering","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Symposium on Product Compliance Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PSES.2007.4378477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

When a fault to ground occurs in HV/MV substations supplied by a combined overhead-cable line, most of the fault current can be transferred and injected into the soil several kilometers far away from the fault location. This phenomenon is called "fault application transfer" and mostly concerns transition stations, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, usually accessible to the general public, the local ground electrode could be inadequate to maintain ground potential rise within safety limits. Hence, dangerous touch and step voltages may appear at exposed locations. In the paper results of various computer simulations are presented, pointing out the main factors affecting the phenomenon and associated hazards.
高压装置接地故障应用转移现象的安全关注
当架空电缆组合线路供电的中高压变电站发生接地故障时,大部分故障电流可被转移注入离故障位置数公里远的土壤中。这种现象被称为“故障应用转移”,主要涉及电缆连接到架空线路的过渡站。如果过渡站为死角钢杆结构,通常对公众开放,则局部地电极可能不足以将地电位上升维持在安全范围内。因此,危险的接触电压和步进电压可能出现在暴露的位置。文中给出了各种计算机模拟的结果,指出了影响该现象的主要因素及其危害。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信