R. van Gestel, K. de Zeeuw, L. van Gemert, E. Bagerman
{"title":"Comparison of delamination effects between temperature cycling test and highly accelerated stress test, in plastic packaged devices","authors":"R. van Gestel, K. de Zeeuw, L. van Gemert, E. Bagerman","doi":"10.1109/RELPHY.1992.187643","DOIUrl":null,"url":null,"abstract":"Two reliability stress tests were performed on, plastic packaged test chips consisting of a temperature cycle test (TCT) of 500 cycles and a highly accelerated stress test (HAST) of 300 h with bias voltage. Before and after the tests delamination of the die-mold interface was examined with scanning acoustic tomography. On these test chips bondwire failures, mechanical deformation, and corrosion test structures have also been measured. It appeared that 300 h of HAST nearly destroyed the adhesion between chip and mold whereas a 500 TCT caused delamination only to initiate from the die corners. The HAST caused a large number of corrosion failures, and the TCT a number of mechanical deformation failures.<<ETX>>","PeriodicalId":154383,"journal":{"name":"30th Annual Proceedings Reliability Physics 1992","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"30th Annual Proceedings Reliability Physics 1992","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RELPHY.1992.187643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24
Abstract
Two reliability stress tests were performed on, plastic packaged test chips consisting of a temperature cycle test (TCT) of 500 cycles and a highly accelerated stress test (HAST) of 300 h with bias voltage. Before and after the tests delamination of the die-mold interface was examined with scanning acoustic tomography. On these test chips bondwire failures, mechanical deformation, and corrosion test structures have also been measured. It appeared that 300 h of HAST nearly destroyed the adhesion between chip and mold whereas a 500 TCT caused delamination only to initiate from the die corners. The HAST caused a large number of corrosion failures, and the TCT a number of mechanical deformation failures.<>