Evaluation of pressure drop characteristics around axial cooling fans with electrical components

T. Fukue, K. Hirose, T. Hatakeyama, M. Ishizuka, K. Koizumi
{"title":"Evaluation of pressure drop characteristics around axial cooling fans with electrical components","authors":"T. Fukue, K. Hirose, T. Hatakeyama, M. Ishizuka, K. Koizumi","doi":"10.1109/ICEP.2016.7486806","DOIUrl":null,"url":null,"abstract":"This paper describes the details of pressure drop characteristics around axial cooling fans mounted in high-density packaging electronic equipment in order to improve prediction accuracy of supply flow rate of the fans in thermal design. Forced air convection cooling driven by cooling fans is the commonest strategy for dissipating heat from electrical devices. Cooling performance of the fans is mainly decided by supply airflow rate. The supply flow rate is strongly affected by pressure drop characteristics in electronic equipment. Especially in the case of high-density packaging electronic equipment, the airflow around the fan generally becomes complex and an accurate prediction of pressure drop characteristics around the fans become significantly difficult. In addition, due to the change of the airflow pattern around the fans by the electrical components mounted near the fans, a deterioration of fan performance itself is sometimes caused. Hence the accurate prediction of supply flow rate of the fans in high-density packaging electronic equipment is generally difficult. However, in order to shorten the period of thermal design, more detailed investigation about airflow characteristics around the fans mounted in high-density packing electronic equipment should be done in order to achieve the accurate prediction of fan's supply flow rate easily. We are trying to develop a prediction model of accurate supply flow rate of the fans mounted in high-density packaging electronic equipment. In this report, the pressure drop characteristic near the axial fan when an obstruction, which simulates electrical components mounted near the fans, is mounted in front of the fan was evaluated while changing the type of the obstruction. The pressure drop around the fan with the obstruction is mainly composed of three factors; the pressure drop around the obstruction, the inlet pressure drop at the fan and the outlet pressure drop from the fan. A level of these pressure drop factors were evaluated quantitatively by comparing experimental results with the conventional pressure drop database. In order to evaluate the accurate supply flow rate of the fan in high-density packaging electronic equipment, an important factor was clarified from the viewpoint of the pressure drop characteristics around the fans.","PeriodicalId":343912,"journal":{"name":"2016 International Conference on Electronics Packaging (ICEP)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Electronics Packaging (ICEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEP.2016.7486806","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper describes the details of pressure drop characteristics around axial cooling fans mounted in high-density packaging electronic equipment in order to improve prediction accuracy of supply flow rate of the fans in thermal design. Forced air convection cooling driven by cooling fans is the commonest strategy for dissipating heat from electrical devices. Cooling performance of the fans is mainly decided by supply airflow rate. The supply flow rate is strongly affected by pressure drop characteristics in electronic equipment. Especially in the case of high-density packaging electronic equipment, the airflow around the fan generally becomes complex and an accurate prediction of pressure drop characteristics around the fans become significantly difficult. In addition, due to the change of the airflow pattern around the fans by the electrical components mounted near the fans, a deterioration of fan performance itself is sometimes caused. Hence the accurate prediction of supply flow rate of the fans in high-density packaging electronic equipment is generally difficult. However, in order to shorten the period of thermal design, more detailed investigation about airflow characteristics around the fans mounted in high-density packing electronic equipment should be done in order to achieve the accurate prediction of fan's supply flow rate easily. We are trying to develop a prediction model of accurate supply flow rate of the fans mounted in high-density packaging electronic equipment. In this report, the pressure drop characteristic near the axial fan when an obstruction, which simulates electrical components mounted near the fans, is mounted in front of the fan was evaluated while changing the type of the obstruction. The pressure drop around the fan with the obstruction is mainly composed of three factors; the pressure drop around the obstruction, the inlet pressure drop at the fan and the outlet pressure drop from the fan. A level of these pressure drop factors were evaluated quantitatively by comparing experimental results with the conventional pressure drop database. In order to evaluate the accurate supply flow rate of the fan in high-density packaging electronic equipment, an important factor was clarified from the viewpoint of the pressure drop characteristics around the fans.
带电气元件的轴流冷却风扇的压降特性评价
本文对高密度封装电子设备中安装的轴流冷却风扇周围的压降特性进行了详细的描述,以提高散热设计中风扇供给流量的预测精度。由冷却风扇驱动的强制空气对流冷却是最常见的从电气设备散热的策略。风机的散热性能主要决定于送风气流量。在电子设备中,供应流量受压降特性的影响很大。特别是在高密度封装电子设备的情况下,风扇周围的气流通常变得复杂,准确预测风扇周围的压降特性变得非常困难。此外,由于安装在风扇附近的电气元件改变了风扇周围的气流模式,有时会导致风扇本身性能的恶化。因此,对高密度封装电子设备中风机的供应流量进行准确预测通常是困难的。然而,为了缩短热设计周期,需要对高密度包装电子设备中安装的风扇周围的气流特性进行更详细的研究,以便于准确预测风扇的供应流量。我们正在尝试建立一个高密度封装电子设备中安装的风扇精确供应流量的预测模型。在本报告中,模拟安装在风机附近的电气元件的障碍物安装在风机前面时,在改变障碍物类型的情况下,评估了轴流风机附近的压降特性。有障碍物的风机周围的压降主要由三个因素组成;障碍物周围的压降,风机的进口压降和风机的出口压降。通过将实验结果与常规压降数据库进行比较,定量评价了这些压降因子的水平。为了准确评估高密度封装电子设备中风机的供给流量,从风机周围压降特性的角度明确了一个重要因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信