{"title":"Surface elemental quantification of Au-Pd pre-plated leadframe by means of X-ray Photoelectron Spectroscopy","authors":"Y. Kee, S. R. Esa, B. A. Rahim, W. A. W. Ismail","doi":"10.1109/IPFA.2016.7564265","DOIUrl":null,"url":null,"abstract":"Quantification of sample with Palladium (Pd) and Gold (Au) using X-ray Photoelectron Spectroscopy (XPS) could be a great challenge due to the overlapping of Pd, Au and Oxygen photoelectron lines. Conventional baseline subtraction method is not applicable when the content of Pd is too low. A metrology for Pd-Au pre-plated leadframe surface atomic percent quantification using XPS deconvolution method was demonstrated to be able to quantify Pd-Au pre-plated leadframe with low Pd content. Three XPS wide scans were performed on the same analysis spot at energy resolutions of 1 eV/step, 0.5 eV/step and 0.1 eV/step respectively. The same metrology was utilized for atomic percent quantification and compare the accuracy based on deconvolution results.","PeriodicalId":206237,"journal":{"name":"2016 IEEE 23rd International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 23rd International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPFA.2016.7564265","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Quantification of sample with Palladium (Pd) and Gold (Au) using X-ray Photoelectron Spectroscopy (XPS) could be a great challenge due to the overlapping of Pd, Au and Oxygen photoelectron lines. Conventional baseline subtraction method is not applicable when the content of Pd is too low. A metrology for Pd-Au pre-plated leadframe surface atomic percent quantification using XPS deconvolution method was demonstrated to be able to quantify Pd-Au pre-plated leadframe with low Pd content. Three XPS wide scans were performed on the same analysis spot at energy resolutions of 1 eV/step, 0.5 eV/step and 0.1 eV/step respectively. The same metrology was utilized for atomic percent quantification and compare the accuracy based on deconvolution results.