{"title":"3 MeV Proton Irradiation of Commercial State of the Art Photonic Mixer Devices","authors":"M. Grimm, B. Voss, E. Wendler","doi":"10.1109/NSREC.2016.7891702","DOIUrl":null,"url":null,"abstract":"Ten identical novel commercial off-the-shelf near range sensors whose working principle is based on a time of flight measurement were irradiated with 3 MeV protons. Degradation effects were observed from 7×10^10 p/cm² on.","PeriodicalId":135325,"journal":{"name":"2016 IEEE Radiation Effects Data Workshop (REDW)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Radiation Effects Data Workshop (REDW)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSREC.2016.7891702","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Ten identical novel commercial off-the-shelf near range sensors whose working principle is based on a time of flight measurement were irradiated with 3 MeV protons. Degradation effects were observed from 7×10^10 p/cm² on.