{"title":"[Improvement of Nitrite Analysis Method in Food Products].","authors":"Takahiro Sasaki, Shoichi Tahara, Mari Morikawa, Tomoki Igarashi, Yuki Sadamasu, Keiko Ushiyama, Yukiko Yamajima, Chigusa Kobayashi","doi":"10.3358/shokueishi.64.21","DOIUrl":null,"url":null,"abstract":"<p><p>The conventional analysis method has problems with extraction efficiency, operability, and reproducibility. In this study, we attempted to solve these problems and improve the analytical method to obtain sufficient extraction efficiency and good operability and accuracy. The conventional method was able to get sufficient extraction in dried meat products, where the extraction efficiency of the conventional method was low, by increasing the concentration of sodium hydroxide solution at the time of homogenization. Suction filtration after adding the defoaming agent was added allowed for accurate volume adjustment. The turbidity of the extract caused by insufficient addition of zinc acetate solution was removed by increasing the amount of zinc acetate solution that was added. Turbidity caused by starch was removed by adding pancreatin. The RSD of the quantitative values was improved by adding sodium hydroxide solution and 80-90℃ water and immediately homogenizing. Furthermore, by changing the dilution factor of the extract solution in the colorimetric method, the inhibition of coloration by reducing substances was suppressed, and more accurate quantitative values could be obtained than with the conventional method. The recovery rate was 78.5-105% (RSD 0.7-5.8%), which was a good result. This method was considered to be a useful analytical method that can contribute to improving the inspection accuracy of nitrite ion analysis.</p>","PeriodicalId":54373,"journal":{"name":"Food Hygiene and Safety Science","volume":"64 1","pages":"21-28"},"PeriodicalIF":0.2000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Hygiene and Safety Science","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.3358/shokueishi.64.21","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
The conventional analysis method has problems with extraction efficiency, operability, and reproducibility. In this study, we attempted to solve these problems and improve the analytical method to obtain sufficient extraction efficiency and good operability and accuracy. The conventional method was able to get sufficient extraction in dried meat products, where the extraction efficiency of the conventional method was low, by increasing the concentration of sodium hydroxide solution at the time of homogenization. Suction filtration after adding the defoaming agent was added allowed for accurate volume adjustment. The turbidity of the extract caused by insufficient addition of zinc acetate solution was removed by increasing the amount of zinc acetate solution that was added. Turbidity caused by starch was removed by adding pancreatin. The RSD of the quantitative values was improved by adding sodium hydroxide solution and 80-90℃ water and immediately homogenizing. Furthermore, by changing the dilution factor of the extract solution in the colorimetric method, the inhibition of coloration by reducing substances was suppressed, and more accurate quantitative values could be obtained than with the conventional method. The recovery rate was 78.5-105% (RSD 0.7-5.8%), which was a good result. This method was considered to be a useful analytical method that can contribute to improving the inspection accuracy of nitrite ion analysis.