Tetraphenylphosphonium Chloride-Enhanced Ionization Coupled to Orbitrap Mass Spectrometry for Sensitive and Non-targeted Screening of Polyhalogenated Alkyl Compounds from Limited Serum

IF 7.3 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Yibin Sun, Song Tang, Hongyang Cui, Chao Wang, Hao Yan, Jianying Hu and Yi Wan*, 
{"title":"Tetraphenylphosphonium Chloride-Enhanced Ionization Coupled to Orbitrap Mass Spectrometry for Sensitive and Non-targeted Screening of Polyhalogenated Alkyl Compounds from Limited Serum","authors":"Yibin Sun,&nbsp;Song Tang,&nbsp;Hongyang Cui,&nbsp;Chao Wang,&nbsp;Hao Yan,&nbsp;Jianying Hu and Yi Wan*,&nbsp;","doi":"10.1021/acs.analchem.2c02158","DOIUrl":null,"url":null,"abstract":"<p >Although many types of halogenated compounds are known to bioaccumulate in humans, few are routinely biomonitored and many have remained uncharacterized in human exposome studies due to a lack of high-sensitivity and high-resolution analytical methods. In this study, we discovered tetraphenylphosphonium chloride (Ph<sub>4</sub>PCl, 10 μM) as a simple additive to the mobile phase, which enhanced the ionizations of polyhalogenated alkyl compounds (such as organochlorinated pesticides [OCPs], chlorinated paraffins [CPs], dechlorane plus [DPs], and some brominated flame retardants [BFRs]) in the form [M + Cl]<sup>−</sup> and boosted mass spectrometry responses by an average of 1–3 orders of magnitude at a resolution of 140,000. Ph<sub>4</sub>PCl-enhanced ionization coupled with a halogenation-guided screening process was used to establish a sensitive and non-targeted method that required only single-step sample preparation and identified Cl- and/or bromine-containing alkyl compounds. The method enabled the identification of ∼700 polyhalogenated compounds from 200 μL of human serum, 240 of which were known compounds: 33 short-chain CPs, 52 median-chain CPs, 97 long-chain CPs, 22 very short-chain CPs (vSCCPs), 19 OCPs, 13 DPs, and 4 BFRs. We also identified 325 emerging contaminants (34 unsaturated CPs, 285 chlorinated fatty acid methyl esters [CFAMEs], and 6 chloro-bromo alkenes) and 130 new contaminants (114 oxygen-containing CPs, 2 hexachlorocyclohexane structural analogs, and 11 amino-containing and 3 nitrate-containing chlorinated compounds). The full scan results highlighted the dominance of CPs, CFAMEs, vSCCPs, and dichlorodiphenyltrichloroethanes in the serum samples. Ph<sub>4</sub>PCl-enhanced ionization enabled the sensitive and non-targeted identifications of polyhalogenated compounds in small volumes of biological fluid.</p>","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"94 41","pages":"14195–14204"},"PeriodicalIF":7.3000,"publicationDate":"2022-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acs.analchem.2c02158","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1

Abstract

Although many types of halogenated compounds are known to bioaccumulate in humans, few are routinely biomonitored and many have remained uncharacterized in human exposome studies due to a lack of high-sensitivity and high-resolution analytical methods. In this study, we discovered tetraphenylphosphonium chloride (Ph4PCl, 10 μM) as a simple additive to the mobile phase, which enhanced the ionizations of polyhalogenated alkyl compounds (such as organochlorinated pesticides [OCPs], chlorinated paraffins [CPs], dechlorane plus [DPs], and some brominated flame retardants [BFRs]) in the form [M + Cl]− and boosted mass spectrometry responses by an average of 1–3 orders of magnitude at a resolution of 140,000. Ph4PCl-enhanced ionization coupled with a halogenation-guided screening process was used to establish a sensitive and non-targeted method that required only single-step sample preparation and identified Cl- and/or bromine-containing alkyl compounds. The method enabled the identification of ∼700 polyhalogenated compounds from 200 μL of human serum, 240 of which were known compounds: 33 short-chain CPs, 52 median-chain CPs, 97 long-chain CPs, 22 very short-chain CPs (vSCCPs), 19 OCPs, 13 DPs, and 4 BFRs. We also identified 325 emerging contaminants (34 unsaturated CPs, 285 chlorinated fatty acid methyl esters [CFAMEs], and 6 chloro-bromo alkenes) and 130 new contaminants (114 oxygen-containing CPs, 2 hexachlorocyclohexane structural analogs, and 11 amino-containing and 3 nitrate-containing chlorinated compounds). The full scan results highlighted the dominance of CPs, CFAMEs, vSCCPs, and dichlorodiphenyltrichloroethanes in the serum samples. Ph4PCl-enhanced ionization enabled the sensitive and non-targeted identifications of polyhalogenated compounds in small volumes of biological fluid.

Abstract Image

四苯基氯化磷增强电离耦合轨道阱质谱法用于有限血清中多卤烷基化合物的灵敏和非靶向筛选
虽然已知许多类型的卤化化合物在人体内具有生物蓄积性,但很少有常规生物监测,而且由于缺乏高灵敏度和高分辨率的分析方法,许多卤化化合物在人体暴露研究中仍未被表征。在本研究中,我们发现四苯基氯化磷(Ph4PCl, 10 μM)作为流动相的简单添加剂,可以增强多卤化烷基化合物(如有机氯农药[OCPs],氯化石蜡[CPs],癸氯烷+ [DPs]和一些溴化阻燃剂[BFRs])以[M + Cl] -的形式电离,并在14万分辨率下将质谱响应平均提高1-3个数量级。采用ph4pcl增强电离结合卤化引导筛选工艺,建立了一种灵敏且非靶向的方法,只需一步样品制备,即可鉴定出含Cl和/或含溴的烷基化合物。该方法能够从200 μL人血清中鉴定出~ 700种多卤化化合物,其中240种为已知化合物:33种短链CPs, 52种中链CPs, 97种长链CPs, 22种甚短链CPs (vSCCPs), 19种OCPs, 13种DPs和4种BFRs。我们还发现了325种新出现的污染物(34种不饱和CPs, 285种氯化脂肪酸甲酯[CFAMEs]和6种氯溴烯烃)和130种新污染物(114种含氧CPs, 2种六氯环己烷结构类似物,11种含氨基和3种含硝酸盐的氯化化合物)。全扫描结果突出了血清样本中CPs、CFAMEs、vSCCPs和二氯二苯三氯乙烷的优势。ph4pcl增强电离使小体积生物流体中多卤化化合物的敏感和非靶向鉴定成为可能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书