Pieralberto Valpiana, Stefano Ghirardelli, Rosa Susanna Valtanen, Salvatore Risitano, Ferdinando Iannotti, Christian Schaller, Karlos Zepeda, Michael Engl, Pier Francesco Indelli
{"title":"易受限制的机器人辅助运动学对齐的生物力学考虑:外科技术笔记。","authors":"Pieralberto Valpiana, Stefano Ghirardelli, Rosa Susanna Valtanen, Salvatore Risitano, Ferdinando Iannotti, Christian Schaller, Karlos Zepeda, Michael Engl, Pier Francesco Indelli","doi":"10.1186/s42836-023-00191-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In total knee arthroplasty, the normal kinematics of the knee may not be restored solely based on preoperative gait, fluoroscopic-based, and dynamic radiostereometric analyses.</p><p><strong>Surgical technique case presentation: </strong>This note introduced a 69-year-old male patient who sustained post-traumatic osteoarthritis of his right knee. He underwent robot-assisted total knee arthroplasty based on anatomical reproduction of knee stability during the swing phase of gait. The kinematic alignment was simply achieved within an easy-to-identified range after preoperative radiographic assessment, intraoperative landmarking and pre-validated osteotomy, and intraoperative range of motion testing.</p><p><strong>Conclusions: </strong>This novel technique allows personalized and imageless total knee arthroplasty. It provides a preliminary path in reproducing the anatomy alignment, natural collateral ligament laxity, and accurate component placement within safe-to-identified alignment boundaries.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10240684/pdf/","citationCount":"1","resultStr":"{\"title\":\"Biomechanical considerations for an easily-restricted robot-assisted kinematic alignment: a surgical technique note.\",\"authors\":\"Pieralberto Valpiana, Stefano Ghirardelli, Rosa Susanna Valtanen, Salvatore Risitano, Ferdinando Iannotti, Christian Schaller, Karlos Zepeda, Michael Engl, Pier Francesco Indelli\",\"doi\":\"10.1186/s42836-023-00191-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In total knee arthroplasty, the normal kinematics of the knee may not be restored solely based on preoperative gait, fluoroscopic-based, and dynamic radiostereometric analyses.</p><p><strong>Surgical technique case presentation: </strong>This note introduced a 69-year-old male patient who sustained post-traumatic osteoarthritis of his right knee. He underwent robot-assisted total knee arthroplasty based on anatomical reproduction of knee stability during the swing phase of gait. The kinematic alignment was simply achieved within an easy-to-identified range after preoperative radiographic assessment, intraoperative landmarking and pre-validated osteotomy, and intraoperative range of motion testing.</p><p><strong>Conclusions: </strong>This novel technique allows personalized and imageless total knee arthroplasty. It provides a preliminary path in reproducing the anatomy alignment, natural collateral ligament laxity, and accurate component placement within safe-to-identified alignment boundaries.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10240684/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s42836-023-00191-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-023-00191-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Biomechanical considerations for an easily-restricted robot-assisted kinematic alignment: a surgical technique note.
Background: In total knee arthroplasty, the normal kinematics of the knee may not be restored solely based on preoperative gait, fluoroscopic-based, and dynamic radiostereometric analyses.
Surgical technique case presentation: This note introduced a 69-year-old male patient who sustained post-traumatic osteoarthritis of his right knee. He underwent robot-assisted total knee arthroplasty based on anatomical reproduction of knee stability during the swing phase of gait. The kinematic alignment was simply achieved within an easy-to-identified range after preoperative radiographic assessment, intraoperative landmarking and pre-validated osteotomy, and intraoperative range of motion testing.
Conclusions: This novel technique allows personalized and imageless total knee arthroplasty. It provides a preliminary path in reproducing the anatomy alignment, natural collateral ligament laxity, and accurate component placement within safe-to-identified alignment boundaries.