{"title":"单切口微型吊带治疗压力性尿失禁的有效性和安全性:一项网络荟萃分析。","authors":"Yuxin Chen, Jiecheng Zhang, Yankai Zeng, Weidong Chen, Fei Liu, Jinchun Xing, Bili Zhang, Yuedong Chen","doi":"10.22037/uj.v20i.7218","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the efficacy and safety of single-incision mini-sling for stress urinary incontinence based on network Meta-analysis.</p><p><strong>Materials and methods: </strong>We searched PubMed, Embase, and Cochrane libraries from August 2008 to August 2019. Randomized controlled trials comparing two or more indicators of Miniarc (Single Incision Mini-slings), Ajust (Adjustable Single-Incision Sling), C-NDL (Contasure-Needleless), TFS (Tissue Fixation System), Ophria (Transobturator Vaginal Tap), TVT-O (Transobturator Vaginal Tape), and TOT (Trans-obturatortape) in treating female stress urinary incontinence were collected.</p><p><strong>Results: </strong>Totally, 3,428 patients from 21 studies were included. Ajust had the highest subjective cure rate (Rank=0.52), while Ophira had the worst (Rank=0.67). TFS had the highest objective cure rate, and the worst was found in Ophira. TFS required the shortest operating time (Rank=0.40), while TVT-O required the longest operating time (Rank=0.47). Miniarc had the least bleeding (Rank=0.47), while TVT-O had the most bleeding (Rank=0.37). C-NDL had the shortest postoperative hospital stay (Rank=0.77), while Ajust had the longest postoperative hospital stay (Rank=0.36). For postoperative complications, TFS performed best in groin pain (Rank=0.84), urinary retention (Rank=0.78), and repeat surgery (Rank=0.45). TVT-O performed worst in groin pain (Rank=0.36), and urinary retention (Rank=0.58). Miniarc had the highest repeat surgery rate (Rank=0.35). Ajust had the lowest probability of tap erosion (Rank=0.30), while Ophira had the highest tap erosion level (Rank=0.45). Miniarc showed the greatest advantage in urinary tract infections (Rank=0.84) and de novo urgency (Rank=0.60), while C-NDL had the highest incidence of urethral infections (Rank=0.51). Ophira performed worst in de novo urgency (Rank=0.60). C-NDL performed the best in sexual intercourse pain (Rank=0.79) while Ajust was the worst (Rank=0.49).</p><p><strong>Conclusions: </strong>In view of comprehensive efficacy and safety, we recommend that TFS or Ajust should be selected first for single-incision sling and the application of Ophria should be minimized.</p>","PeriodicalId":23416,"journal":{"name":"Urology Journal","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The Efficacy and Safety of Single-Incision Mini-Slings for Stress Urinary Incontinence: A Network Meta-Analysis.\",\"authors\":\"Yuxin Chen, Jiecheng Zhang, Yankai Zeng, Weidong Chen, Fei Liu, Jinchun Xing, Bili Zhang, Yuedong Chen\",\"doi\":\"10.22037/uj.v20i.7218\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the efficacy and safety of single-incision mini-sling for stress urinary incontinence based on network Meta-analysis.</p><p><strong>Materials and methods: </strong>We searched PubMed, Embase, and Cochrane libraries from August 2008 to August 2019. Randomized controlled trials comparing two or more indicators of Miniarc (Single Incision Mini-slings), Ajust (Adjustable Single-Incision Sling), C-NDL (Contasure-Needleless), TFS (Tissue Fixation System), Ophria (Transobturator Vaginal Tap), TVT-O (Transobturator Vaginal Tape), and TOT (Trans-obturatortape) in treating female stress urinary incontinence were collected.</p><p><strong>Results: </strong>Totally, 3,428 patients from 21 studies were included. Ajust had the highest subjective cure rate (Rank=0.52), while Ophira had the worst (Rank=0.67). TFS had the highest objective cure rate, and the worst was found in Ophira. TFS required the shortest operating time (Rank=0.40), while TVT-O required the longest operating time (Rank=0.47). Miniarc had the least bleeding (Rank=0.47), while TVT-O had the most bleeding (Rank=0.37). C-NDL had the shortest postoperative hospital stay (Rank=0.77), while Ajust had the longest postoperative hospital stay (Rank=0.36). For postoperative complications, TFS performed best in groin pain (Rank=0.84), urinary retention (Rank=0.78), and repeat surgery (Rank=0.45). TVT-O performed worst in groin pain (Rank=0.36), and urinary retention (Rank=0.58). Miniarc had the highest repeat surgery rate (Rank=0.35). Ajust had the lowest probability of tap erosion (Rank=0.30), while Ophira had the highest tap erosion level (Rank=0.45). Miniarc showed the greatest advantage in urinary tract infections (Rank=0.84) and de novo urgency (Rank=0.60), while C-NDL had the highest incidence of urethral infections (Rank=0.51). Ophira performed worst in de novo urgency (Rank=0.60). C-NDL performed the best in sexual intercourse pain (Rank=0.79) while Ajust was the worst (Rank=0.49).</p><p><strong>Conclusions: </strong>In view of comprehensive efficacy and safety, we recommend that TFS or Ajust should be selected first for single-incision sling and the application of Ophria should be minimized.</p>\",\"PeriodicalId\":23416,\"journal\":{\"name\":\"Urology Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Urology Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.22037/uj.v20i.7218\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urology Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.22037/uj.v20i.7218","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
The Efficacy and Safety of Single-Incision Mini-Slings for Stress Urinary Incontinence: A Network Meta-Analysis.
Purpose: To evaluate the efficacy and safety of single-incision mini-sling for stress urinary incontinence based on network Meta-analysis.
Materials and methods: We searched PubMed, Embase, and Cochrane libraries from August 2008 to August 2019. Randomized controlled trials comparing two or more indicators of Miniarc (Single Incision Mini-slings), Ajust (Adjustable Single-Incision Sling), C-NDL (Contasure-Needleless), TFS (Tissue Fixation System), Ophria (Transobturator Vaginal Tap), TVT-O (Transobturator Vaginal Tape), and TOT (Trans-obturatortape) in treating female stress urinary incontinence were collected.
Results: Totally, 3,428 patients from 21 studies were included. Ajust had the highest subjective cure rate (Rank=0.52), while Ophira had the worst (Rank=0.67). TFS had the highest objective cure rate, and the worst was found in Ophira. TFS required the shortest operating time (Rank=0.40), while TVT-O required the longest operating time (Rank=0.47). Miniarc had the least bleeding (Rank=0.47), while TVT-O had the most bleeding (Rank=0.37). C-NDL had the shortest postoperative hospital stay (Rank=0.77), while Ajust had the longest postoperative hospital stay (Rank=0.36). For postoperative complications, TFS performed best in groin pain (Rank=0.84), urinary retention (Rank=0.78), and repeat surgery (Rank=0.45). TVT-O performed worst in groin pain (Rank=0.36), and urinary retention (Rank=0.58). Miniarc had the highest repeat surgery rate (Rank=0.35). Ajust had the lowest probability of tap erosion (Rank=0.30), while Ophira had the highest tap erosion level (Rank=0.45). Miniarc showed the greatest advantage in urinary tract infections (Rank=0.84) and de novo urgency (Rank=0.60), while C-NDL had the highest incidence of urethral infections (Rank=0.51). Ophira performed worst in de novo urgency (Rank=0.60). C-NDL performed the best in sexual intercourse pain (Rank=0.79) while Ajust was the worst (Rank=0.49).
Conclusions: In view of comprehensive efficacy and safety, we recommend that TFS or Ajust should be selected first for single-incision sling and the application of Ophria should be minimized.
期刊介绍:
As the official journal of the Urology and Nephrology Research Center (UNRC) and the Iranian Urological Association (IUA), Urology Journal is a comprehensive digest of useful information on modern urology. Emphasis is on practical information that reflects the latest diagnostic and treatment techniques. Our objectives are to provide an exceptional source of current and clinically relevant research in the discipline of urology, to reflect the scientific work and progress of our colleagues, and to present the articles in a logical, timely, and concise format that meets the diverse needs of today’s urologist.
Urology Journal publishes manuscripts on urology and kidney transplantation, all of which undergo extensive peer review by recognized authorities in the field prior to their acceptance for publication. Accordingly, original articles, case reports, and letters to editor are encouraged.