临床新手在不同牙支撑水平的后牙无牙区进行静态计算机辅助种植的准确性。

IF 1.1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
J Abduo, D Lau
{"title":"临床新手在不同牙支撑水平的后牙无牙区进行静态计算机辅助种植的准确性。","authors":"J Abduo, D Lau","doi":"10.1922/EJPRD_2494Abduo10","DOIUrl":null,"url":null,"abstract":"<p><p>Correct implant placement is necessary for satisfactory implant restoration. Therefore, the use of surgical guide is recommended. This study evaluated the accuracy of implant placement in posterior edentulous areas with different levels of tooth-support by novice clinicians according to fully-guided (FG), pilot-guided (PG), and freehand (FH) placement protocols. A mandibular model with missing first molars was designed. On one side, the model had a bound edentulous area (BEA), and on the other side, a free end edentulous area (FEA). Fourteen clinicians new to implant dentistry participated in the study, and each clinician inserted an implant in the BEA and FEA sites for every placement protocol. Angle, vertical and maximum horizontal platform and apex deviations were measured. The FG placement was more accurate than the PG and FH placements. This was significant for BEA angle deviation, BEA and FEA maximum horizontal platform deviations, and BEA maximum horizontal apex deviation. The PG placement was significantly more accurate than the FH placement for BEA and FEA maximum horizontal platform deviations. FG shows significantly greater angle, maximum horizontal platform and maximum horizontal apex deviations at FEA than BEA. This can be attributed to reduced guide support and the possibility of guide displacement during surgery.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Accuracy of Static Computer- Assisted Implant Placement in Posterior Edentulous Areas with Different Levels of Tooth- Support by Novice Clinicians.\",\"authors\":\"J Abduo, D Lau\",\"doi\":\"10.1922/EJPRD_2494Abduo10\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Correct implant placement is necessary for satisfactory implant restoration. Therefore, the use of surgical guide is recommended. This study evaluated the accuracy of implant placement in posterior edentulous areas with different levels of tooth-support by novice clinicians according to fully-guided (FG), pilot-guided (PG), and freehand (FH) placement protocols. A mandibular model with missing first molars was designed. On one side, the model had a bound edentulous area (BEA), and on the other side, a free end edentulous area (FEA). Fourteen clinicians new to implant dentistry participated in the study, and each clinician inserted an implant in the BEA and FEA sites for every placement protocol. Angle, vertical and maximum horizontal platform and apex deviations were measured. The FG placement was more accurate than the PG and FH placements. This was significant for BEA angle deviation, BEA and FEA maximum horizontal platform deviations, and BEA maximum horizontal apex deviation. The PG placement was significantly more accurate than the FH placement for BEA and FEA maximum horizontal platform deviations. FG shows significantly greater angle, maximum horizontal platform and maximum horizontal apex deviations at FEA than BEA. This can be attributed to reduced guide support and the possibility of guide displacement during surgery.</p>\",\"PeriodicalId\":45686,\"journal\":{\"name\":\"European Journal of Prosthodontics and Restorative Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Prosthodontics and Restorative Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1922/EJPRD_2494Abduo10\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Prosthodontics and Restorative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1922/EJPRD_2494Abduo10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

正确的种植体放置是获得满意种植体修复的必要条件。因此,建议使用手术指南。本研究评估了临床新手根据全引导(FG)、导航引导(PG)和徒手(FH)放置方案在不同牙支持水平的后牙无牙区种植体放置的准确性。设计了缺失第一磨牙的下颌模型。模型的一侧为边界无牙区(BEA),另一侧为自由端无牙区(FEA)。14位临床医生参与了这项研究,每位临床医生在BEA和FEA位置插入种植体。测量角度、垂直和最大水平平台和顶点偏差。FG放置比PG和FH放置更准确。这在BEA角偏差、BEA和FEA最大水平平台偏差和BEA最大水平顶点偏差上具有显著性。对于BEA和FEA最大水平平台偏差,PG定位明显比FH定位更准确。在有限元分析中,FG的角度、最大水平平台和最大水平顶点偏差明显大于BEA。这可归因于手术过程中减少的引导支撑和引导移位的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of Static Computer- Assisted Implant Placement in Posterior Edentulous Areas with Different Levels of Tooth- Support by Novice Clinicians.

Correct implant placement is necessary for satisfactory implant restoration. Therefore, the use of surgical guide is recommended. This study evaluated the accuracy of implant placement in posterior edentulous areas with different levels of tooth-support by novice clinicians according to fully-guided (FG), pilot-guided (PG), and freehand (FH) placement protocols. A mandibular model with missing first molars was designed. On one side, the model had a bound edentulous area (BEA), and on the other side, a free end edentulous area (FEA). Fourteen clinicians new to implant dentistry participated in the study, and each clinician inserted an implant in the BEA and FEA sites for every placement protocol. Angle, vertical and maximum horizontal platform and apex deviations were measured. The FG placement was more accurate than the PG and FH placements. This was significant for BEA angle deviation, BEA and FEA maximum horizontal platform deviations, and BEA maximum horizontal apex deviation. The PG placement was significantly more accurate than the FH placement for BEA and FEA maximum horizontal platform deviations. FG shows significantly greater angle, maximum horizontal platform and maximum horizontal apex deviations at FEA than BEA. This can be attributed to reduced guide support and the possibility of guide displacement during surgery.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
7.70%
发文量
0
期刊介绍: The European Journal of Prosthodontics and Restorative Dentistry is published quarterly and includes clinical and research articles in subjects such as prosthodontics, operative dentistry, implantology, endodontics, periodontics and dental materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信